Redfish driver
==============
Overview
========
The ``redfish`` driver enables managing servers compliant with the
Redfish_ protocol.
Prerequisites
=============
* The Sushy_ library should be installed on the ironic conductor node(s).
For example, it can be installed with ``pip``::
sudo pip install sushy
Enabling the Redfish driver
===========================
#. Add ``redfish`` to the list of ``enabled_hardware_types``,
``enabled_power_interfaces``, ``enabled_management_interfaces`` and
``enabled_inspect_interfaces`` as well as ``redfish-virtual-media``
to ``enabled_boot_interfaces`` in ``/etc/ironic/ironic.conf``.
For example::
[DEFAULT]
...
enabled_hardware_types = ipmi,redfish
enabled_boot_interfaces = ipmitool,redfish-virtual-media
enabled_power_interfaces = ipmitool,redfish
enabled_management_interfaces = ipmitool,redfish
enabled_inspect_interfaces = inspector,redfish
#. Restart the ironic conductor service::
sudo service ironic-conductor restart
# Or, for RDO:
sudo systemctl restart openstack-ironic-conductor
Registering a node with the Redfish driver
===========================================
Nodes configured to use the driver should have the ``driver`` property
set to ``redfish``.
The following properties are specified in the node's ``driver_info``
field:
- ``redfish_address``: The URL address to the Redfish controller. It must
include the authority portion of the URL, and can
optionally include the scheme. If the scheme is
missing, https is assumed.
For example: https://mgmt.vendor.com. This is required.
- ``redfish_system_id``: The canonical path to the ComputerSystem resource
that the driver will interact with. It should include
the root service, version and the unique resource
path to the ComputerSystem. This property is only
required if target BMC manages more than one
ComputerSystem. Otherwise ironic will pick the only
available ComputerSystem automatically. For
example: /redfish/v1/Systems/1.
- ``redfish_username``: User account with admin/server-profile access
privilege. Although not required, it is highly
recommended.
- ``redfish_password``: User account password. Although not required, it is
highly recommended.
- ``redfish_verify_ca``: If redfish_address has the **https** scheme, the
driver will use a secure (TLS_) connection when
talking to the Redfish controller. By default
(if this is not set or set to True), the driver
will try to verify the host certificates. This
can be set to the path of a certificate file or
directory with trusted certificates that the
driver will use for verification. To disable
verifying TLS_, set this to False. This is optional.
- ``redfish_auth_type``: Redfish HTTP client authentication method. Can be
"basic", "session" or "auto".
The "auto" mode first tries "session" and falls back
to "basic" if session authentication is not supported
by the Redfish BMC. Default is set in ironic config
as ``[redfish]auth_type``.
The ``openstack baremetal node create`` command can be used to enroll
a node with the ``redfish`` driver. For example:
.. code-block:: bash
openstack baremetal node create --driver redfish --driver-info \
redfish_address=https://example.com --driver-info \
redfish_system_id=/redfish/v1/Systems/CX34R87 --driver-info \
redfish_username=admin --driver-info redfish_password=password \
--name node-0
For more information about enrolling nodes see :ref:`enrollment`
in the install guide.
Features of the ``redfish`` hardware type
=========================================
Boot mode support
^^^^^^^^^^^^^^^^^
The ``redfish`` hardware type can read current boot mode from the
bare metal node as well as set it to either Legacy BIOS or UEFI.
.. note::
Boot mode management is the optional part of the Redfish specification.
Not all Redfish-compliant BMCs might implement it. In that case
it remains the responsibility of the operator to configure proper
boot mode to their bare metal nodes.
Out-Of-Band inspection
^^^^^^^^^^^^^^^^^^^^^^
The ``redfish`` hardware type can inspect the bare metal node by querying
Redfish compatible BMC. This process is quick and reliable compared to the
way the ``inspector`` hardware type works i.e. booting bare metal node
into the introspection ramdisk.
.. note::
The ``redfish`` inspect interface relies on the optional parts of the
Redfish specification. Not all Redfish-compliant BMCs might serve the
required information, in which case bare metal node inspection will fail.
.. note::
The ``local_gb`` property cannot always be discovered, for example, when a
node does not have local storage or the Redfish implementation does not
support the required schema. In this case the property will be set to 0.
Virtual media boot
^^^^^^^^^^^^^^^^^^
The idea behind virtual media boot is that BMC gets hold of the boot image
one way or the other (e.g. by HTTP GET, other methods are defined in the
standard), then "inserts" it into node's virtual drive as if it was burnt
on a physical CD/DVD. The node can then boot from that virtual drive into
the operating system residing on the image.
The major advantage of virtual media boot feature is that potentially
unreliable TFTP image transfer phase of PXE protocol suite is fully
eliminated.
Hardware types based on the ``redfish`` fully support booting deploy/rescue
and user images over virtual media. Ironic builds bootable ISO images, for
either UEFI or BIOS (Legacy) boot modes, at the moment of node deployment out
of kernel and ramdisk images associated with the ironic node.
To boot a node managed by ``redfish`` hardware type over virtual media using
BIOS boot mode, it suffice to set ironic boot interface to
``redfish-virtual-media``, as opposed to ``ipmitool``.
.. code-block:: bash
openstack baremetal node set --boot-interface redfish-virtual-media node-0
If UEFI boot mode is desired, the user should additionally supply EFI
System Partition image (ESP_) via ``[driver-info]/bootloader`` ironic node
property or ironic configuration file in form of Glance image UUID or a URL.
.. code-block:: bash
openstack baremetal node set --driver-info bootloader=<glance-uuid> node-0
If ``[driver_info]/config_via_floppy`` boolean property of the node is set to
``true``, ironic will create a file with runtime configuration parameters,
place into on a FAT image, then insert the image into node's virtual floppy
drive.
When booting over PXE or virtual media, and user instance requires some
specific kernel configuration, ``[instance_info]/kernel_append_params``
property can be used to pass user-specified kernel command line parameters.
For ramdisk kernel, ``[instance_info]/kernel_append_params`` property serves
the same purpose.
.. _Redfish: http://redfish.dmtf.org/
.. _Sushy: https://opendev.org/openstack/sushy
.. _TLS: https://en.wikipedia.org/wiki/Transport_Layer_Security
.. _ESP: https://wiki.ubuntu.com/EFIBootLoaders#Booting_from_EFI