SNMP driver
The SNMP power driver enables control of power distribution units of the type frequently found in data centre racks. PDUs frequently have a management ethernet interface and SNMP support enabling control of the power outlets.
The SNMP power driver works with the PXE driver for network deployment and network-configured boot.
List of supported devices
This is a non-exhaustive list of supported devices. Any device not listed in this table could possibly work using a similar driver.
Please report any device status.
Manufacturer | Model | Supported? | Driver name |
---|---|---|---|
APC | AP7920 | Yes | apc_masterswitch |
APC | AP9606 | Yes | apc_masterswitch |
APC | AP9225 | Yes | apc_masterswitchplus |
APC | AP7155 | Yes | apc_rackpdu |
APC | AP7900 | Yes | apc_rackpdu |
APC | AP7901 | Yes | apc_rackpdu |
APC | AP7902 | Yes | apc_rackpdu |
APC | AP7911a | Yes | apc_rackpdu |
APC | AP7921 | Yes | apc_rackpdu |
APC | AP7922 | Yes | apc_rackpdu |
APC | AP7930 | Yes | apc_rackpdu |
APC | AP7931 | Yes | apc_rackpdu |
APC | AP7932 | Yes | apc_rackpdu |
APC | AP7940 | Yes | apc_rackpdu |
APC | AP7941 | Yes | apc_rackpdu |
APC | AP7951 | Yes | apc_rackpdu |
APC | AP7960 | Yes | apc_rackpdu |
APC | AP7990 | Yes | apc_rackpdu |
APC | AP7998 | Yes | apc_rackpdu |
APC | AP8941 | Yes | apc_rackpdu |
APC | AP8953 | Yes | apc_rackpdu |
APC | AP8959 | Yes | apc_rackpdu |
APC | AP8961 | Yes | apc_rackpdu |
APC | AP8965 | Yes | apc_rackpdu |
Aten | all? | Yes | aten |
CyberPower | all? | Untested | cyberpower |
EatonPower | all? | Untested | eatonpower |
Teltronix | all? | Yes | teltronix |
Software Requirements
- The PySNMP package must be installed, variously referred to as
pysnmp
orpython-pysnmp
Enabling the SNMP Power Driver
Add
snmp
to the list ofenabled_hardware_types
inironic.conf
. Also updateenabled_management_interfaces
andenabled_power_interfaces
inironic.conf
as shown below:[DEFAULT] enabled_hardware_types = snmp enabled_management_interfaces = fake enabled_power_interfaces = snmp
Alternatively, if you prefer using the classic driver instead of the
snmp
hardware type, addpxe_snmp
to the list ofenabled_drivers
inironic.conf
:[DEFAULT] enabled_drivers = pxe_snmp
To set the default boot option, update
default_boot_option
inironic.conf
:[DEFAULT] default_boot_option = netboot
Note
Currently the default value of
default_boot_option
isnetboot
but it will be changed tolocal
in the future. It is recommended to set an explicit value for this option.Note
It is important to set
boot_option
tonetboot
as SNMP drivers do not support setting of boot devices. One can also configure a node to boot usingnetboot
by setting itscapabilities
and updating Nova flavor as described below:openstack baremetal node set --property capabilities="boot_option:netboot" <node-uuid> openstack flavor set --property "capabilities:boot_option"="netboot" ironic-flavor
Restart the Ironic conductor service.
service ironic-conductor restart
Ironic Node Configuration
Nodes configured to use the SNMP driver should have the
driver
field set to the hardware type snmp
(preferred) or to the classic driver pxe_snmp
.
The following property values have to be added to the node's
driver_info
field:
snmp_driver
: PDU manufacturer driversnmp_address
: the IPv4 address of the PDU controlling this node.snmp_port
: (optional) A non-standard UDP port to use for SNMP operations. If not specified, the default port (161) is used.snmp_outlet
: The power outlet on the PDU (1-based indexing).snmp_version
: (optional) SNMP protocol version (permitted values1
,2c
or3
). If not specified, SNMPv1 is chosen.snmp_community
: (Required for SNMPv1 and SNMPv2c) SNMP community parameter for reads and writes to the PDU.snmp_security
: (Required for SNMPv3) SNMPv3 User-based Security Model (USM) user name.
The following command can be used to enroll a node with the
snmp
driver:
openstack baremetal node create --os-baremetal-api-version=1.31 \
--driver snmp --driver-info snmp_driver=<pdu_manufacturer> \
--driver-info snmp_address=<ip_address> \
--driver-info snmp_outlet=<outlet_index> \
--driver-info snmp_community=<community_string> \
--properties capabilities=boot_option:netboot
PDU Configuration
This version of the SNMP power driver does not support SNMPv3
authentication or encryption features. When using SNMPv3, the SNMPv3
agent at the PDU must be configured in noAuthNoPriv
mode.
Also, the snmp_security
parameter is used to configure SNMP
USM user name to the SNMP manager at the power driver. The same USM user
name must be configured to the target SNMP agent.