iRMC drivers

Overview

The iRMC driver enables control FUJITSU PRIMERGY via ServerView Common Command Interface (SCCI).

There are 3 iRMC drivers:

  • pxe_irmc.
  • iscsi_irmc
  • agent_irmc

Prerequisites

Drivers

pxe_irmc driver

This driver enables PXE deploy and power control via ServerView Common Command Interface (SCCI).

Enabling the driver

  • Add pxe_irmc to the list of enabled_drivers in [DEFAULT] section of /etc/ironic/ironic.conf.
  • Ironic Conductor must be restarted for the new driver to be loaded.

Node configuration

  • Each node is configured for iRMC with PXE deploy by setting the following ironic node objects properties:
    • driver property to be pxe_irmc
    • driver_info/irmc_address property to be IP address or hostname of the iRMC.
    • driver_info/irmc_username property to be username for the iRMC with administrator privileges.
    • driver_info/irmc_password property to be password for irmc_username.
    • properties/capabilities property to be boot_mode:uefi if UEFI boot is required.
  • All of nodes are configured by setting the following configuration options in [irmc] section of /etc/ironic/ironic.conf:
    • port: Port to be used for iRMC operations; either 80 or 443. The default value is 443. Optional.
    • auth_method: Authentication method for iRMC operations; either basic or digest. The default value is basic. Optional.
    • client_timeout: Timeout (in seconds) for iRMC operations. The default value is 60. Optional.
    • sensor_method: Sensor data retrieval method; either ipmitool or scci. The default value is ipmitool. Optional.
  • Each node can be further configured by setting the following ironic node objects properties which override the parameter values in [irmc] section of /etc/ironic/ironic.conf:
    • driver_info/irmc_port property overrides port.
    • driver_info/irmc_auth_method property overrides auth_method.
    • driver_info/irmc_client_timeout property overrides client_timeout.
    • driver_info/irmc_sensor_method property overrides sensor_method.

iscsi_irmc driver

This driver enables Virtual Media deploy with image build from Diskimage Builder and power control via ServerView Common Command Interface (SCCI).

Enabling the driver

  • Add iscsi_irmc to the list of enabled_drivers in [DEFAULT] section of /etc/ironic/ironic.conf.
  • Ironic Conductor must be restarted for the new driver to be loaded.

Node configuration

  • Each node is configured for iRMC with PXE deploy by setting the followings ironic node objects properties:
    • driver property to be iscsi_irmc
    • driver_info/irmc_address property to be IP address or hostname of the iRMC.
    • driver_info/irmc_username property to be username for the iRMC with administrator privileges.
    • driver_info/irmc_password property to be password for irmc_username.
    • properties/capabilities property to be boot_mode:uefi if UEFI boot is required.
    • driver_info/irmc_deploy_iso property to be either deploy iso file name, Glance UUID, Glance URL or Image Service URL.
    • instance info/irmc_boot_iso property to be either boot iso file name, Glance UUID, Glance URL or Image Service URL. This is optional property for netboot.
  • All of nodes are configured by setting the following configuration options in [irmc] section of /etc/ironic/ironic.conf:
    • port: Port to be used for iRMC operations; either 80 or 443. The default value is 443. Optional.
    • auth_method: Authentication method for iRMC operations; either basic or digest. The default value is basic. Optional.
    • client_timeout: Timeout (in seconds) for iRMC operations. The default value is 60. Optional.
    • sensor_method: Sensor data retrieval method; either ipmitool or scci. The default value is ipmitool. Optional.
    • remote_image_share_root: Ironic conductor node's NFS or CIFS root path. The default value is /remote_image_share_root.
    • remote_image_server: IP of remote image server.
    • remote_image_share_type: Share type of virtual media, either NFS or CIFS. The default is CIFS.
    • remote_image_share_name: share name of remote_image_server. The default value is share.
    • remote_image_user_name: User name of remote_image_server.
    • remote_image_user_password: Password of remote_image_user_name.
    • remote_image_user_domain: Domain name of remote_image_user_name.
  • Each node can be further configured by setting the following ironic node objects properties which override the parameter values in [irmc] section of /etc/ironic/ironic.conf:
    • driver_info/irmc_port property overrides port.
    • driver_info/irmc_auth_method property overrides auth_method.
    • driver_info/irmc_client_timeout property overrides client_timeout.
    • driver_info/irmc_sensor_method property overrides sensor_method.

agent_irmc driver

This driver enables Virtual Media deploy with IPA (Ironic Python Agent) and power control via ServerView Common Command Interface (SCCI).

Enabling the driver

  • Add agent_irmc to the list of enabled_drivers in [DEFAULT] section of /etc/ironic/ironic.conf.
  • Ironic Conductor must be restarted for the new driver to be loaded.

Node configuration

  • Each node is configured for iRMC with PXE deploy by setting the followings ironic node objects properties:
    • driver property to be agent_irmc
    • driver_info/irmc_address property to be IP address or hostname of the iRMC.
    • driver_info/irmc_username property to be username for the iRMC with administrator privileges.
    • driver_info/irmc_password property to be password for irmc_username.
    • properties/capabilities property to be boot_mode:uefi if UEFI boot is required.
    • driver_info/irmc_deploy_iso property to be either deploy iso file name, Glance UUID, Glance URL or Image Service URL.
  • All of nodes are configured by setting the following configuration options in [irmc] section of /etc/ironic/ironic.conf:
    • port: Port to be used for iRMC operations; either 80 or 443. The default value is 443. Optional.
    • auth_method: Authentication method for iRMC operations; either basic or digest. The default value is basic. Optional.
    • client_timeout: Timeout (in seconds) for iRMC operations. The default value is 60. Optional.
    • sensor_method: Sensor data retrieval method; either ipmitool or scci. The default value is ipmitool. Optional.
    • remote_image_share_root: Ironic conductor node's NFS or CIFS root path. The default value is /remote_image_share_root.
    • remote_image_server: IP of remote image server.
    • remote_image_share_type: Share type of virtual media, either NFS or CIFS. The default is CIFS.
    • remote_image_share_name: share name of remote_image_server. The default value is share.
    • remote_image_user_name: User name of remote_image_server.
    • remote_image_user_password: Password of remote_image_user_name.
    • remote_image_user_domain: Domain name of remote_image_user_name.
  • Each node can be further configured by setting the following ironic node objects properties which override the parameter values in [irmc] section of /etc/ironic/ironic.conf:
    • driver_info/irmc_port property overrides port.
    • driver_info/irmc_auth_method property overrides auth_method.
    • driver_info/irmc_client_timeout property overrides client_timeout.
    • driver_info/irmc_sensor_method property overrides sensor_method.

Supported platforms

This driver supports FUJITSU PRIMERGY BX S4 or RX S8 servers and above.

  • PRIMERGY BX920 S4
  • PRIMERGY BX924 S4
  • PRIMERGY RX300 S8