91e036cc39
The ironic inspector iPXE configuration includes the following kernel
argument:
initrd=agent.ramdisk
However, the ramdisk is actually called ironic-agent.initramfs, so the
argument should be:
initrd=ironic-agent.initramfs
In BIOS boot mode this does not cause a problem, but for compute nodes
with UEFI enabled, it seems to be more strict about this, and fails to
boot.
Change-Id: Ic84f3b79fdd3cd1730ca2fb79c11c7a4e4d824de
Closes-Bug: #1836375
(cherry picked from commit
|
||
---|---|---|
.. | ||
inspector.ipxe.j2 | ||
ironic_pxe_uefi.default.j2 | ||
ironic-api.json.j2 | ||
ironic-conductor.json.j2 | ||
ironic-dnsmasq.conf.j2 | ||
ironic-dnsmasq.json.j2 | ||
ironic-inspector.conf.j2 | ||
ironic-inspector.json.j2 | ||
ironic-ipxe-httpd.conf.j2 | ||
ironic-ipxe.json.j2 | ||
ironic-pxe.json.j2 | ||
ironic.conf.j2 | ||
pxelinux.default.j2 |