Copyright (c) 2014 EMC Corporation
|
|
All Rights Reserved.
|
|
|
|
Licensed under the Apache License, Version 2.0 (the "License"); you may
|
|
not use this file except in compliance with the License. You may obtain
|
|
a copy of the License at
|
|
|
|
http://www.apache.org/licenses/LICENSE-2.0
|
|
|
|
Unless required by applicable law or agreed to in writing, software
|
|
distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
|
|
WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
|
|
License for the specific language governing permissions and limitations
|
|
under the License.
|
|
|
|
VNX Driver
|
|
==========
|
|
|
|
EMC manila driver framework (EMCShareDriver) utilizes the EMC storage products
|
|
to provide the shared filesystems to OpenStack. The EMC manila driver is a
|
|
plugin based driver which is designed to use different plugins to manage
|
|
different EMC storage products.
|
|
|
|
VNX plugin is the plugin which manages the VNX to provide shared filesystems.
|
|
EMC driver framework with VNX plugin is referred to as VNX driver in this
|
|
document.
|
|
|
|
This driver performs the operations on VNX by XMLAPI and the File command line.
|
|
Each backend manages one Data Mover of VNX. Multiple manila backends need to
|
|
be configured to manage multiple Data Movers.
|
|
|
|
Requirements
|
|
------------
|
|
|
|
- VNX OE for File version 7.1 or higher.
|
|
- VNX Unified, File only, or Gateway system with single storage backend.
|
|
- The following licenses should be activated on VNX for File:
|
|
* CIFS
|
|
* NFS
|
|
* SnapSure (for snapshot)
|
|
* ReplicationV2 (for create share from snapshot)
|
|
|
|
Supported Operations
|
|
--------------------
|
|
|
|
The following operations will be supported on VNX array:
|
|
|
|
- Create CIFS/NFS Share
|
|
- Delete CIFS/NFS Share
|
|
- Allow CIFS/NFS Share access
|
|
* Only IP access type is supported for NFS.
|
|
* Only user access type is supported for CIFS.
|
|
- Deny CIFS/NFS Share access
|
|
- Create snapshot
|
|
- Delete snapshot
|
|
- Create share from snapshot
|
|
|
|
While the generic driver creates shared filesystems based on Cinder volumes
|
|
attached to Nova VMs, the VNX driver performs similar operations using the
|
|
Data Movers on the array.
|
|
|
|
Pre-Configurations on VNX
|
|
-------------------------
|
|
|
|
1. Enable Unicode on Data mover
|
|
|
|
VNX driver requires that the Unicode is enabled on Data Mover.
|
|
|
|
CAUTION: After enabling Unicode, you cannot disable it. If there are some
|
|
filesystems created before Unicode is enabled on the VNX, consult the storage
|
|
administrator before enabling Unicode.
|
|
|
|
To check the Unicode status on Data Mover, use the following VNX File command
|
|
on VNX control station:
|
|
|
|
server_cifs <mover_name> | head
|
|
where:
|
|
mover_name = <name of the Data Mover>
|
|
|
|
Check the value of `I18N mode` field. UNICODE mode is shown as `I18N mode =
|
|
UNICODE`
|
|
|
|
To enable the Unicode for Data Mover:
|
|
|
|
uc_config -on -mover <mover_name>
|
|
where:
|
|
mover_name = <name of the Data Mover>
|
|
|
|
Refer to the document `Using International Character Sets on VNX for File`
|
|
on [EMC support site](https://support.emc.com) for more information.
|
|
|
|
2. Enable CIFS service on Data Mover
|
|
|
|
Ensure the CIFS service is enabled on the Data Mover which is going to be
|
|
managed by VNX driver.
|
|
|
|
To start the CIFS service, use the following command:
|
|
|
|
server_setup <mover_name> -Protocol cifs -option start [=<n>]
|
|
where:
|
|
<mover_name> = <name of the Data Mover>
|
|
[=<n>] = <number of threads for CIFS users>
|
|
|
|
Note: If there is 1 GB of memory on the Data Mover, the default is 96 threads;
|
|
however, if there is over 1 GB of memory, the default number of threads is 256.
|
|
|
|
To check the CIFS service status, use this command:
|
|
|
|
server_cifs <mover_name> | head
|
|
where:
|
|
<mover_name> = <name of the Data Mover>
|
|
|
|
The command output will show the number of CIFS threads started.
|
|
|
|
3. NTP settings on Data Mover
|
|
|
|
VNX driver only supports CIFS share creation with share network which has an
|
|
Active Directory security-service associated.
|
|
|
|
Creating CIFS share requires that the time on the Data Mover is in sync with
|
|
the Active Directory domain so that the CIFS server can join the domain.
|
|
Otherwise, the domain join will fail when creating share with this security
|
|
service. There is a limitation that the time of the domains used by
|
|
security-services even for different tenants and different share networks
|
|
should be in sync. Time difference should be less than 10 minutes.
|
|
|
|
It is recommended to set the NTP server to the same public NTP server on both
|
|
the Data Mover and domains used in security services to ensure the time is in
|
|
sync everywhere.
|
|
|
|
Check the date and time on Data Mover:
|
|
|
|
server_date <mover_name>
|
|
where:
|
|
mover_name = <name of the Data Mover>
|
|
|
|
Set the NTP server for Data Mover:
|
|
|
|
server_date <mover_name> timesvc start ntp <host> [<host> ...]
|
|
where:
|
|
mover_name = <name of the Data Mover>
|
|
host = <IP address of the time server host>
|
|
|
|
Note: The host must be running the NTP protocol. Only 4 host entries are
|
|
allowed.
|
|
|
|
4. Configure User Mapping on the Data Mover
|
|
|
|
Before creating CIFS share using VNX driver, you must select a method of
|
|
mapping Windows SIDs to UIDs and GIDs. EMC recommends using usermapper in
|
|
single protocol (CIFS) environment which is enabled on VNX by default.
|
|
|
|
To check usermapper status, use this command syntax:
|
|
|
|
server_usermapper <movername>
|
|
where:
|
|
<movername> = <name of the Data Mover>
|
|
|
|
If usermapper is not started, the following command can be used to start the
|
|
usermapper:
|
|
|
|
server_usermapper <movername> -enable
|
|
where:
|
|
<movername> = <name of the Data Mover>
|
|
|
|
For multiple protocol environment, refer to `Configuring VNX User Mapping` on
|
|
[EMC support site](https://support.emc.com) for additional information.
|
|
|
|
5. Network Connection
|
|
|
|
In the current release, the share created by VNX driver uses the first network
|
|
device (physical port on NIC) of Data Mover to access the network.
|
|
|
|
Go to Unisphere to check the device list:
|
|
Settings -> Network -> Settings for File (Unified system only) -> Device.
|
|
|
|
Backend Configuration
|
|
---------------------
|
|
|
|
The following parameters need to be configured in `/etc/manila/manila.conf`
|
|
for the VNX driver:
|
|
|
|
emc_share_backend = vnx
|
|
emc_nas_server = <IP address>
|
|
emc_nas_password = <password>
|
|
emc_nas_login = <user>
|
|
emc_nas_server_container = <Data Mover name>
|
|
emc_nas_pool_name = <pool name>
|
|
emc_interface_ports = <Comma separated ports list>
|
|
share_driver = manila.share.drivers.dell_emc.driver.EMCShareDriver
|
|
driver_handles_share_servers = True
|
|
|
|
- `emc_share_backend` is the plugin name. Set it to `vnx` for the VNX driver.
|
|
- `emc_nas_server` is the control station IP address of the VNX system to be
|
|
managed.
|
|
- `emc_nas_password` and `emc_nas_login` fields are used to provide credentials
|
|
to the VNX system. Only local users of VNX File is supported.
|
|
- `emc_nas_server_container` field is the name of the Data Mover to serve the
|
|
share service.
|
|
- `emc_nas_pool_name` is the pool name user wants to create volume from. The
|
|
pools can be created using Unisphere for VNX.
|
|
- `emc_interface_ports` is comma separated list specifying the ports(devices) of
|
|
Data Mover that can be used for share server interface.
|
|
Members of the list can be Unix-style glob expressions (supports Unix shell-style
|
|
wildcards). This list is optional. In the absence of this option, any of the ports
|
|
on the Data Mover can be used.
|
|
- `driver_handles_share_servers` must be True, the driver will choose a port
|
|
from port list which configured in emc_interface_ports.
|
|
|
|
Restart of :term:`manila-share` service is needed for the configuration changes to take
|
|
effect.
|
|
|
|
IPv6 support
|
|
------------
|
|
|
|
IPv6 support for VNX driver is introduced in Queens release. The feature is divided
|
|
into two parts:
|
|
|
|
1. The driver is able to manage share or snapshot in the Neutron IPv6 network.
|
|
2. The driver is able to connect VNX management interface using its IPv6 address.
|
|
|
|
Pre-Configurations for IPv6 support
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The following parameters need to be configured in `/etc/manila/manila.conf`
|
|
for the VNX driver:
|
|
|
|
network_plugin_ipv6_enabled = True
|
|
|
|
- `network_plugin_ipv6_enabled` indicates IPv6 is enabled.
|
|
|
|
If you want to connect VNX using IPv6 address, you should configure IPv6 address
|
|
by `nas_cs` command for VNX and specify the address in `/etc/manila/manila.conf`:
|
|
|
|
emc_nas_server = <IPv6 address>
|
|
|
|
Snapshot support
|
|
----------------
|
|
|
|
In the Mitaka and Newton release of OpenStack, Snapshot support is enabled by default for a newly created share type.
|
|
Starting with the Ocata release, the snapshot_support extra spec must be set to True in order to allow snapshots for
|
|
a share type. If the 'snapshot_support' extra_spec is omitted or if it is set to False, users would not be able to
|
|
create snapshots on shares of this share type. The feature is divided into two parts:
|
|
|
|
1. The driver is able to create/delete snapshot of share.
|
|
2. The driver is able to create share from snapshot.
|
|
|
|
Pre-Configurations for Snapshot support
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The following extra specifications need to be configured with share type.
|
|
|
|
- snapshot_support = True
|
|
- create_share_from_snapshot_support = True
|
|
|
|
For new share type, these extra specifications can be set directly when creating share type:
|
|
|
|
.. code-block:: console
|
|
|
|
manila type-create --snapshot_support True --create_share_from_snapshot_support True ${share_type_name} True
|
|
|
|
Or you can update already existing share type with command:
|
|
|
|
.. code-block:: console
|
|
|
|
manila type-key ${share_type_name} set snapshot_support=True
|
|
manila type-key ${share_type_name} set create_share_from_snapshot_support=True
|
|
|
|
To snapshot a share and create share from the snapshot
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Firstly, you need create a share from share type that has extra specifications(snapshot_support=True, create_share_from_snapshot_support=True).
|
|
Then snapshot the share with command:
|
|
|
|
.. code-block:: console
|
|
|
|
manila snapshot-create ${source_share_name} --name ${target_snapshot_name} --description " "
|
|
|
|
After creating the snapshot from previous step, you can create share from that snapshot.
|
|
Use command:
|
|
|
|
.. code-block:: console
|
|
|
|
manila create nfs 1 --name ${target_share_name} --metadata source=snapshot --description " " --snapshot-id ${source_snapshot_id}
|
|
|
|
Restrictions
|
|
------------
|
|
|
|
The VNX driver has the following restrictions:
|
|
|
|
- Only IP access type is supported for NFS.
|
|
|
|
- Only user access type is supported for CIFS.
|
|
|
|
- Only FLAT network and VLAN network are supported.
|
|
|
|
- VLAN network is supported with limitations. The Neutron subnets in different
|
|
VLANs that are used to create share networks cannot have overlapped address
|
|
spaces. Otherwise, VNX may have a problem to communicate with the hosts in
|
|
the VLANs. To create shares for different VLANs with same subnet address, use
|
|
different Data Movers.
|
|
|
|
- The 'Active Directory' security service is the only supported security
|
|
service type and it is required to create CIFS shares.
|
|
|
|
- Only one security service can be configured for each share network.
|
|
|
|
- Active Directory domain name of the 'active_directory' security service
|
|
should be unique even for different tenants.
|
|
|
|
- The time on Data Mover and the Active Directory domains used in security
|
|
services should be in sync (time difference should be less than 10 minutes).
|
|
It is recommended to use same NTP server on both the Data Mover and Active
|
|
Directory domains.
|
|
|
|
- On VNX the snapshot is stored in the SavVols. VNX system allows the space
|
|
used by SavVol to be created and extended until the sum of the space consumed
|
|
by all SavVols on the system exceeds the default 20% of the total space
|
|
available on the system. If the 20% threshold value is reached, an alert will
|
|
be generated on VNX. Continuing to create snapshot will cause the old
|
|
snapshot to be inactivated (and the snapshot data to be abandoned). The limit
|
|
percentage value can be changed manually by storage administrator based on
|
|
the storage needs. Administrator is recommended to configure the notification
|
|
on the SavVol usage. Refer to `Using VNX SnapSure` document on [EMC support
|
|
site](https://support.emc.com) for more information.
|
|
|
|
- VNX has limitations on the overall numbers of Virtual Data Movers,
|
|
filesystems, shares, checkpoints, and etc. Virtual Data Mover(VDM) is created
|
|
by the VNX driver on the VNX to serve as the manila share server. Similarly,
|
|
filesystem is created, mounted, and exported from the VDM over CIFS or NFS
|
|
protocol to serve as the manila share. The VNX checkpoint serves as the
|
|
manila share snapshot. Refer to the `NAS Support Matrix` document on [EMC
|
|
support site](https://support.emc.com) for the limitations and configure the
|
|
quotas accordingly.
|
|
|
|
The :mod:`manila.share.drivers.dell_emc.driver` Module
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
.. automodule:: manila.share.drivers.dell_emc.driver
|
|
:noindex:
|
|
:members:
|
|
:undoc-members:
|
|
:show-inheritance:
|
|
|
|
The :mod:`manila.share.drivers.dell_emc.plugins.vnx.connection` Module
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
.. automodule:: manila.share.drivers.dell_emc.plugins.vnx.connection
|
|
:noindex:
|
|
:members:
|
|
:undoc-members:
|
|
:show-inheritance:
|