Update hypervisor version
Updated hypervisor version to 8 (integer) rather than the string
value previosly ('710'). Only the major version value is reported
because conductor enforces the source host for a live migration
be less than or equal to the destination host version. PowerVM
uses capability flags to determine if migration between hosts
is valid rather than comparing version levels.
Closes-Bug: #1498100
Change-Id: Iff53df8d933f2aff9662dee7083becab2a195510
This commit is contained in:
@@ -30,7 +30,15 @@ from pypowervm.tasks.monitor import util as pcm_util
|
||||
LOG = logging.getLogger(__name__)
|
||||
|
||||
# Power VM hypervisor info
|
||||
IBM_POWERVM_HYPERVISOR_VERSION = '710'
|
||||
# Normally, the hypervisor version is a string in the form of '8.0.0' and
|
||||
# converted to an int with nova.virt.utils.convert_version_to_int() however
|
||||
# there isn't currently a mechanism to retrieve the exact version.
|
||||
# Complicating this is the fact that nova conductor only allows live migration
|
||||
# from the source host to the destination if the source is equal to or less
|
||||
# than the destination version. PowerVM live migration limitations are
|
||||
# checked by the PowerVM capabilities flags and not specific version levels.
|
||||
# For that reason, we'll just publish the major level.
|
||||
IBM_POWERVM_HYPERVISOR_VERSION = 8
|
||||
|
||||
# The types of LPARS that are supported.
|
||||
POWERVM_SUPPORTED_INSTANCES = jsonutils.dumps([(arch.PPC64,
|
||||
|
||||
Reference in New Issue