Update Python base version from 3.6 to 3.8. For Zed the minimum Python runtime versions are Python 3.8 and 3.9 [1]. As a third Python version I also added 3.10 already. Removed ThreadedHTTPServer and replaced it with ThreadingHTTPServer from standard library, which is new in Python 3.7. [1]: https://governance.openstack.org/tc/reference/runtimes/zed.html Change-Id: I035c569b4feaa23b00c0cad50c36aaecf06f7848
3.2 KiB
Testing with Octavia
Unit Testing
Octavia uses tox to manage the virtual environments for running test cases.
Install python-tox:
$ pip install tox
To run the full suite of tests maintained within Octavia.
$ tox
Note
The first time you run tox
, it will take additional time
to build virtualenvs. You can later use the -r
option with
tox
to rebuild your virtualenv in a similar manner.
To run tests for one or more specific test environments(for example,
the most common configuration of Python 3.8 and PEP-8), list the
environments with the -e
option, separated by spaces:
$ tox -e py38,pep8
See tox -l
for the full list of available test
environments.
Structure of the Unit Test Tree
The structure of the unit test tree should match the structure of the code tree, e.g. :
- target module: octavia.common.utils
- test module: octavia.tests.unit.common.test_utils
Unit test modules should have the same path under octavia/tests/unit/ as the module they target has under octavia/, and their name should be the name of the target module prefixed by test_. This requirement is intended to make it easier for developers to find the unit tests for a given module.
Similarly, when a test module targets a package, that module's name should be the name of the package prefixed by test_ with the same path as when a test targets a module, e.g. :
- target package: octavia.hacking
- test module: octavia.tests.unit.test_hacking
The following command can be used to validate whether the unit test tree is structured according to the above requirements: :
./tools/check_unit_test_structure.sh
Where appropriate, exceptions can be added to the above script. If code is not part of the Octavia namespace, for example, it's probably reasonable to exclude their unit tests from the check.
Functional Testing
Octavia creates a simulated API and handler for its functional tests. The tests then run requests against the mocked up API.
To run the entire suite of functional tests:
$ tox -e functional
To run a specific functional test:
$ tox -e functional octavia.tests.functional.api.v2.test_load_balancer
Tests can also be run using partial matching, to run all API tests for v2:
$ tox -e functional api.v2
Additional options can be used while running tests. Two useful
options that can be used when running tests are
-- --until-failure
which will run the tests in a loop until
the first failure is hit, and -- --failing
which if used
after an initial run will only run the tests that failed in the previous
run.
Scenario Testing
Octavia uses Tempest to cover the scenario tests for the project. These tests are run against actual cloud deployments.
To run the entire suite of scenario tests:
$ tox -e scenario
Note
The first time running the Tempest scenario tests export the Tempest configuration directory (i.e. TEMPEST_CONFIG_DIR=/opt/stack/tempest/etc)