Parts of the documentation about log offloading repeated itself. I added a new "Failover Considerations" section that focuses on that topic specifically. Therefore, other sections no longer need to show multi-server configurations. The new section contains recommendations about log_retry_count and log_retry_interval values for failover configurations as well. Story: 2009876 Task: 44599 Change-Id: If71fce80329fe772c8248bc2eb4445ea15680c5d
299 lines
12 KiB
ReStructuredText
299 lines
12 KiB
ReStructuredText
..
|
|
Copyright 2019 Red Hat, Inc. All rights reserved.
|
|
|
|
Licensed under the Apache License, Version 2.0 (the "License"); you may
|
|
not use this file except in compliance with the License. You may obtain
|
|
a copy of the License at
|
|
|
|
http://www.apache.org/licenses/LICENSE-2.0
|
|
|
|
Unless required by applicable law or agreed to in writing, software
|
|
distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
|
|
WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
|
|
License for the specific language governing permissions and limitations
|
|
under the License.
|
|
|
|
==============================
|
|
Octavia Amphora Log Offloading
|
|
==============================
|
|
|
|
The default logging configuration will store the logs locally, on the amphora
|
|
filesystem with file rotation.
|
|
|
|
Octavia Amphorae can offload their log files via the syslog protocol to syslog
|
|
receivers via the load balancer management network (lb-mgmt-net). This allows
|
|
log aggregation of both administrative logs and also tenant traffic flow logs.
|
|
The syslog receivers can either be local to the load balancer management
|
|
network or routable via the load balancer management network.
|
|
By default any syslog receiver that supports UDP or TCP syslog protocol can
|
|
be used, however the operator also has the option to create an override
|
|
rsyslog configuration template to enable other features or protocols their
|
|
Amphora image may support.
|
|
|
|
This guide will discuss the features of :term:`Amphora` log offloading and how
|
|
to configure them.
|
|
|
|
Administrative Logs
|
|
===================
|
|
|
|
The administrative log offloading feature of the :term:`Amphora` covers all of
|
|
the system logging inside the :term:`Amphora` except for the tenant flow logs.
|
|
Tenant flow logs can be sent to and processed by the same syslog receiver used
|
|
by the administrative logs, but they are configured separately.
|
|
|
|
All administrative log messages will be sent using the native log format
|
|
for the application sending the message.
|
|
|
|
Enabling Administrative Log Offloading
|
|
--------------------------------------
|
|
|
|
One or more syslog receiver endpoints must be configured in the Octavia
|
|
configuration file to enable administrative log offloading. The first endpoint
|
|
will be the primary endpoint to receive the syslog packets.
|
|
Read the :ref:`rsyslog failover considerations` section for information about
|
|
how to use multiple target servers.
|
|
|
|
To configure administrative log offloading, set the following setting in your
|
|
Octavia configuration file for all of the controllers and restart them:
|
|
|
|
.. code-block:: ini
|
|
|
|
[amphora_agent]
|
|
admin_log_targets = 192.0.2.1:10514
|
|
|
|
In this example, the syslog receiver will be 192.0.2.1 on port 10514.
|
|
If *log_protocol* is not specified UDP will be used.
|
|
|
|
.. note::
|
|
|
|
Make sure your syslog receiver endpoints are accessible from the load
|
|
balancer management network and you have configured the required
|
|
security group or firewall rules to allow the traffic. These endpoints
|
|
can be routable addresses from the load balancer management network.
|
|
|
|
The load balancer related administrative logs will be sent using a
|
|
LOG_LOCAL[0-7] facility. The facility number defaults to 1, but is configurable
|
|
using the administrative_log_facility setting in the Octavia configuration
|
|
file.
|
|
|
|
To configure administrative log facility, set the following setting in your
|
|
Octavia configuration file for all of the controllers and restart them:
|
|
|
|
.. code-block:: ini
|
|
|
|
[amphora_agent]
|
|
administrative_log_facility = 1
|
|
|
|
Forwarding All Administrative Logs
|
|
----------------------------------
|
|
|
|
By default, the Amphorae will only forward load balancer related administrative
|
|
logs, such as the haproxy admin logs, keepalived, and :term:`Amphora` agent
|
|
logs.
|
|
You can optionally configure the Amphorae to send all of the administrative
|
|
logs from the :term:`Amphora`, such as the kernel, system, and security logs.
|
|
Even with this setting the tenant flow logs will not be included. You can
|
|
configure tenant flow log forwarding in the `Tenant Flow Logs`_ section.
|
|
|
|
The load balancer related administrative logs will be sent using the
|
|
LOG_LOCAL[0-7] configured using the administrative_log_facility setting. All
|
|
other administrative log messages will use their native syslog facilities.
|
|
|
|
To configure the Amphorae to forward all administrative logs, set the following
|
|
setting in your Octavia configuration file for all of the controllers and
|
|
restart them:
|
|
|
|
.. code-block:: ini
|
|
|
|
[amphora_agent]
|
|
forward_all_logs = True
|
|
|
|
Tenant Flow Logs
|
|
================
|
|
|
|
Enabling Tenant Flow Log Offloading
|
|
-----------------------------------
|
|
|
|
One or more syslog receiver endpoints must be configured in the Octavia
|
|
configuration file to enable tenant flow log offloading. The first endpoint
|
|
will be the primary endpoint to receive the syslog packets.
|
|
The endpoints configured for tenant flow log offloading may be
|
|
the same endpoints as the administrative log offloading configuration.
|
|
Read the :ref:`rsyslog failover considerations` section for information
|
|
about how to use multiple target servers.
|
|
|
|
.. warning::
|
|
|
|
Tenant flow logging can produce a large number of syslog messages
|
|
depending on how many connections the load balancers are receiving.
|
|
Tenant flow logging produces one log entry per connection to the
|
|
load balancer. We recommend you monitor, size, and configure your syslog
|
|
receivers appropriately based on the expected number of connections your
|
|
load balancers will be handling.
|
|
|
|
To configure tenant flow log offloading, set the following setting in your
|
|
Octavia configuration file for all of the controllers and restart them:
|
|
|
|
.. code-block:: ini
|
|
|
|
[amphora_agent]
|
|
tenant_log_targets = 192.0.2.1:10514
|
|
|
|
In this example, the syslog receiver will be 192.0.2.1 on port 10514.
|
|
If *log_protocol* is not specified UDP will be used.
|
|
|
|
.. note::
|
|
|
|
Make sure your syslog receiver endpoints are accessible from the load
|
|
balancer management network and you have configured the required
|
|
security group or firewall rules to allow the traffic. These endpoints
|
|
can be routable addresses from the load balancer management network.
|
|
|
|
The load balancer related tenant flow logs will be sent using a
|
|
LOG_LOCAL[0-7] facility. The facility number defaults to 0, but is configurable
|
|
using the user_log_facility setting in the Octavia configuration file.
|
|
|
|
To configure the tenant flow log facility, set the following setting in your
|
|
Octavia configuration file for all of the controllers and restart them:
|
|
|
|
.. code-block:: ini
|
|
|
|
[amphora_agent]
|
|
user_log_facility = 0
|
|
|
|
Tenant Flow Log Format
|
|
----------------------
|
|
|
|
The default tenant flow log format is:
|
|
|
|
.. code-block::
|
|
|
|
project_id loadbalancer_id listener_id client_ip client_port data_time
|
|
request_string http_status bytes_read bytes_uploaded
|
|
client_certificate_verify(0 or 1) client_certificate_distinguised_name
|
|
pool_id member_id processing_time(ms) termination_state
|
|
|
|
Any field that is unknown or not applicable to the connection will have a '-'
|
|
character in its place.
|
|
|
|
An example log entry when using rsyslog as the syslog receiver is:
|
|
|
|
.. note::
|
|
|
|
The prefix[1] in this example comes from the rsyslog receiver and is not
|
|
part of the syslog message from the amphora.
|
|
|
|
[1] "Jun 12 00:44:13 amphora-3e0239c3-5496-4215-b76c-6abbe18de573 haproxy[1644]:"
|
|
|
|
.. code-block::
|
|
|
|
Jun 12 00:44:13 amphora-3e0239c3-5496-4215-b76c-6abbe18de573 haproxy[1644]: 5408b89aa45b48c69a53dca1aaec58db fd8f23df-960b-4b12-ba62-2b1dff661ee7 261ecfc2-9e8e-4bba-9ec2-3c903459a895 172.24.4.1 41152 12/Jun/2019:00:44:13.030 "GET / HTTP/1.1" 200 76 73 - "" e37e0e04-68a3-435b-876c-cffe4f2138a4 6f2720b3-27dc-4496-9039-1aafe2fee105 4 --
|
|
|
|
Custom Tenant Flow Log Format
|
|
-----------------------------
|
|
|
|
You can optionally specify a custom log format for the tenant flow logs.
|
|
This string follows the HAProxy log format variables with the exception of
|
|
the "{{ project_id }}" and "{{ lb_id }}" variables that will be replaced
|
|
by the Octavia :term:`Amphora` driver. These custom variables are optional.
|
|
|
|
See the HAProxy documentation for `Custom log format <http://cbonte.github.io/haproxy-dconv/1.9/configuration.html#8.2.4>`_ variable definitions.
|
|
|
|
To configure a custom log format, set the following setting in your
|
|
Octavia configuration file for all of the controllers and restart them:
|
|
|
|
.. code-block:: ini
|
|
|
|
[haproxy_amphora]
|
|
user_log_format = '{{ project_id }} {{ lb_id }} %f %ci %cp %t %{+Q}r %ST %B %U %[ssl_c_verify] %{+Q}[ssl_c_s_dn] %b %s %Tt %tsc'
|
|
|
|
.. _rsyslog failover considerations:
|
|
|
|
Failover Considerations
|
|
=======================
|
|
|
|
In order to provide protection against potential data loss because of
|
|
downtime of a single syslog server, it may be a advisable to
|
|
use multiple log targets.
|
|
In such configuration *log_protocol* needs to be set to *TCP*.
|
|
With the UDP syslog protocol, RSyslog is unable
|
|
to detect if the primary endpoint has failed.
|
|
|
|
Also pay attention to the *log_retry_count* and *log_retry_interval* settings
|
|
when using multiple log targets. You might want to set *log_retry_count* to 0
|
|
and use a higher value for *log_retry_interval*. Values up to 1800 (30 minutes)
|
|
are possible.
|
|
That way the failover will happen immediately after the client detects
|
|
that the server became unavailable. In such case, that server won't be
|
|
used again for at least *log_retry_interval* seconds after that event.
|
|
In the following example the primary syslog receiver will be
|
|
192.0.2.1 on port 10514.
|
|
The backup syslog receiver will be 2001:db8:1::10 on port 10514.
|
|
|
|
.. code-block:: ini
|
|
|
|
[amphora_agent]
|
|
admin_log_targets = 192.0.2.1:10514, 2001:db8:1::10:10514
|
|
tenant_log_targets = 192.0.2.1:10514, 2001:db8:1::10:10514
|
|
log_protocol = TCP
|
|
log_retry_count = 0
|
|
log_retry_interval = 1800
|
|
|
|
Disabling Logging
|
|
=================
|
|
|
|
There may be cases where you need to disable logging inside the
|
|
:term:`Amphora`, such as complying with regulatory standards.
|
|
Octavia provides multiple options for disabling :term:`Amphora` logging.
|
|
|
|
Disable Local Log Storage
|
|
-------------------------
|
|
|
|
This setting stops log entries from being written to the disk inside the
|
|
:term:`Amphora`. Logs can still be sent via :term:`Amphora` log offloading if
|
|
log offloading is configured for the Amphorae. Enabling this setting may
|
|
provide a performance benefit to the load balancer.
|
|
|
|
.. warning::
|
|
|
|
This feature disables ALL log storage in the :term:`Amphora`, including
|
|
kernel, system, and security logging.
|
|
|
|
.. note::
|
|
|
|
If you enable this setting and are not using :term:`Amphora` log
|
|
offloading, we recommend you also `Disable Tenant Flow Logging`_ to
|
|
improve load balancing performance.
|
|
|
|
To disable local log storage in the :term:`Amphora`, set the following setting
|
|
in your Octavia configuration file for all of the controllers and restart them:
|
|
|
|
.. code-block:: ini
|
|
|
|
[amphora_agent]
|
|
disable_local_log_storage = True
|
|
|
|
Disable Tenant Flow Logging
|
|
---------------------------
|
|
|
|
This setting allows you to disable tenant flow logging irrespective of the
|
|
other logging configuration settings. It will take precedent over the other
|
|
settings. When this setting is enabled, no tenant flow (connection) logs will
|
|
be written to the disk inside the :term:`Amphora` or be sent via the
|
|
:term:`Amphora` log offloading.
|
|
|
|
.. note::
|
|
|
|
Disabling tenant flow logging can also improve the load balancing
|
|
performance of the amphora. Due to the potential performance improvement,
|
|
we recommend you enable this setting when using the
|
|
`Disable Local Log Storage`_ setting.
|
|
|
|
To disable tenant flow logging, set the following setting in your Octavia
|
|
configuration file for all of the controllers and restart them:
|
|
|
|
.. code-block:: ini
|
|
|
|
[haproxy_amphora]
|
|
connection_logging = False
|