update alarm docs
alarm docs reference stuff that has been deprecated or removed from aodh: - add valid threshold types and mark threshold type as deprecated - mark combination alarms as deprecated and removed in pike - change ceilometerclient alarm redirect commands to use aodhclient - update docs to use composite alarms rather than combination alarms - remove note saying alarm history is retained for deleted alarms. it isn't anymore: I5f6d7a1998104335079b7988e3d0b929b8854b28 Change-Id: Iaaf6b36db9cc41a0f347427fd19e1d0d77712ed0
This commit is contained in:
@@ -43,12 +43,33 @@ governed by:
|
||||
* A sliding time window to indicate how far back into the recent past
|
||||
you want to look.
|
||||
|
||||
Valid threshold alarms are: ``gnocchi_resources_threshold_rule``,
|
||||
``gnocchi_aggregation_by_metrics_threshold_rule``, or
|
||||
``gnocchi_aggregation_by_resources_threshold_rule``.
|
||||
|
||||
.. note::
|
||||
|
||||
As of Ocata, the ``threshold`` alarm is deprecated since Ceilometer's
|
||||
native storage API is deprecated.
|
||||
|
||||
Composite rule alarms
|
||||
---------------------
|
||||
|
||||
Composite alarms enable users to define an alarm with multiple triggering
|
||||
conditions, using a combination of ``and`` and ``or`` relations.
|
||||
|
||||
|
||||
Combination rule alarms
|
||||
-----------------------
|
||||
|
||||
.. note::
|
||||
|
||||
Combination alarms are deprecated as of Newton for composite alarms.
|
||||
Combination alarm functionality is removed in Pike.
|
||||
|
||||
The Telemetry service also supports the concept of a meta-alarm, which
|
||||
aggregates over the current state of a set of underlying basic alarms
|
||||
combined via a logical operator (AND or OR).
|
||||
combined via a logical operator (``and`` or ``or``).
|
||||
|
||||
Alarm dimensioning
|
||||
~~~~~~~~~~~~~~~~~~
|
||||
@@ -123,18 +144,18 @@ Using alarms
|
||||
Alarm creation
|
||||
--------------
|
||||
|
||||
An example of creating a threshold-oriented alarm, based on an upper
|
||||
An example of creating a Gnocchi threshold-oriented alarm, based on an upper
|
||||
bound on the CPU utilization for a particular instance:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
$ ceilometer alarm-threshold-create --name cpu_hi \
|
||||
$ aodh alarm create --name cpu_hi \
|
||||
--type gnocchi_resources_threshold \
|
||||
--description 'instance running hot' \
|
||||
--meter-name cpu_util --threshold 70.0 \
|
||||
--comparison-operator gt --statistic avg \
|
||||
--period 600 --evaluation-periods 3 \
|
||||
--alarm-action 'log://' \
|
||||
--query resource_id=INSTANCE_ID
|
||||
--metric cpu_util --threshold 70.0 \
|
||||
--comparison-operator gt --aggregation_method avg \
|
||||
--granularity 600 --evaluation-periods 3 \
|
||||
--alarm-action 'log://' --resource_id INSTANCE_ID
|
||||
|
||||
This creates an alarm that will fire when the average CPU utilization
|
||||
for an individual instance exceeds 70% for three consecutive 10
|
||||
@@ -157,16 +178,10 @@ time boundaries, rather it's anchored on the current time for each
|
||||
evaluation cycle, and continually creeps forward as each evaluation
|
||||
cycle rolls around (by default, this occurs every minute).
|
||||
|
||||
The period length is set to 600s in this case to reflect the
|
||||
out-of-the-box default cadence for collection of the associated
|
||||
meter. This period matching illustrates an important general
|
||||
principal to keep in mind for alarms:
|
||||
|
||||
.. note::
|
||||
|
||||
The alarm period should be a whole number multiple (1 or more)
|
||||
of the interval configured in the pipeline corresponding to the
|
||||
target meter.
|
||||
The alarm granularity must match the granularities of the metric configured
|
||||
in Gnocchi.
|
||||
|
||||
Otherwise the alarm will tend to flit in and out of the
|
||||
``insufficient data`` state due to the mismatch between the actual
|
||||
@@ -210,16 +225,26 @@ state of two underlying alarms:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
$ ceilometer alarm-combination-create --name meta \
|
||||
--alarm_ids ALARM_ID1 \
|
||||
--alarm_ids ALARM_ID2 \
|
||||
--operator or \
|
||||
$ aodh alarm create --name meta --type composite \
|
||||
--composite-rule '{"or":[{"threshold": 0.8,"metric": "cpu_util", "type": \
|
||||
"gnocchi_resources_threshold", "resource_id": INSTANCE_ID, \
|
||||
"aggregation-method": "last"},{"threshold": 0.8,"metric": "cpu_util", \
|
||||
"type": "gnocchi_resources_threshold", "resource_id": INSTANCE_ID2, \
|
||||
"aggregation-method": "last"}]}' \
|
||||
--alarm-action 'http://example.org/notify'
|
||||
|
||||
This creates an alarm that will fire when either one of two underlying
|
||||
alarms transition into the alarm state. The notification in this case
|
||||
is a webhook call. Any number of underlying alarms can be combined in
|
||||
this way, using either ``and`` or ``or``.
|
||||
this way, using either ``and`` or ``or``. Additionally, combinations
|
||||
can contain nested conditions:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
$ aodh alarm create --name meta --type composite \
|
||||
--composite-rule '{"or":[ALARM_1, {"and":[ALARM2, ALARM3]}]}'
|
||||
--alarm-action 'http://example.org/notify'
|
||||
|
||||
|
||||
Alarm retrieval
|
||||
---------------
|
||||
@@ -229,12 +254,12 @@ brevity):
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
$ ceilometer alarm-list
|
||||
+----------+--------+-------------------+---------------------------------+
|
||||
| Alarm ID | Name | State | Alarm condition |
|
||||
+----------+--------+-------------------+---------------------------------+
|
||||
| ALARM_ID | cpu_hi | insufficient data | cpu_util > 70.0 during 3 x 600s |
|
||||
+----------+--------+-------------------+---------------------------------+
|
||||
$ aodh alarm list
|
||||
+----------+-----------+--------+-------------------+----------+---------+
|
||||
| Alarm ID | Type | Name | State | Severity | Enabled |
|
||||
+----------+-----------+--------+-------------------+----------+---------+
|
||||
| ALARM_ID | threshold | cpu_hi | insufficient data | high | True |
|
||||
+----------+-----------+--------+-------------------+----------+---------+
|
||||
|
||||
In this case, the state is reported as ``insufficient data`` which
|
||||
could indicate that:
|
||||
@@ -269,7 +294,7 @@ any other alarm attribute) can be updated thusly:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
$ ceilometer alarm-update --threshold 75 ALARM_ID
|
||||
$ aodh alarm update ALARM_ID --threshold 75
|
||||
|
||||
The change will take effect from the next evaluation cycle, which by
|
||||
default occurs every minute.
|
||||
@@ -289,7 +314,7 @@ via the audit API:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
$ ceilometer alarm-history ALARM_ID
|
||||
$ aodh alarm-history show ALARM_ID
|
||||
+------------------+-----------+---------------------------------------+
|
||||
| Type | Timestamp | Detail |
|
||||
+------------------+-----------+---------------------------------------+
|
||||
@@ -309,14 +334,10 @@ longer actively evaluated:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
$ ceilometer alarm-update --enabled False -a ALARM_ID
|
||||
$ aodh alarm update --enabled False -a ALARM_ID
|
||||
|
||||
or even deleted permanently (an irreversible step):
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
$ ceilometer alarm-delete ALARM_ID
|
||||
|
||||
.. note::
|
||||
|
||||
By default, alarm history is retained for deleted alarms.
|
||||
$ aodh alarm delete ALARM_ID
|
||||
|
||||
Reference in New Issue