95ebcd402a
Change-Id: I457c5500e37835bc1ebde5150ae073ab0f1ae27e Implements: blueprint use-openstack-command
1109 lines
36 KiB
ReStructuredText
1109 lines
36 KiB
ReStructuredText
==============
|
||
EMC VNX driver
|
||
==============
|
||
|
||
EMC VNX driver interacts with configured VNX array. It supports
|
||
both iSCSI and FC protocol.
|
||
|
||
The VNX cinder driver performs the volume operations by
|
||
executing Navisphere CLI (NaviSecCLI) which is a command-line interface used
|
||
for management, diagnostics, and reporting functions for VNX. It also
|
||
supports both iSCSI and FC protocol.
|
||
|
||
|
||
System requirements
|
||
~~~~~~~~~~~~~~~~~~~
|
||
|
||
- VNX Operational Environment for Block version 5.32 or higher.
|
||
- VNX Snapshot and Thin Provisioning license should be activated for VNX.
|
||
- Python library ``storops`` to interact with VNX.
|
||
- Navisphere CLI v7.32 or higher is installed along with the driver.
|
||
|
||
Supported operations
|
||
~~~~~~~~~~~~~~~~~~~~
|
||
|
||
- Create, delete, attach, and detach volumes.
|
||
- Create, list, and delete volume snapshots.
|
||
- Create a volume from a snapshot.
|
||
- Copy an image to a volume.
|
||
- Clone a volume.
|
||
- Extend a volume.
|
||
- Migrate a volume.
|
||
- Retype a volume.
|
||
- Get volume statistics.
|
||
- Create and delete consistency groups.
|
||
- Create, list, and delete consistency group snapshots.
|
||
- Modify consistency groups.
|
||
- Efficient non-disruptive volume backup.
|
||
- Create a cloned consistency group.
|
||
- Create a consistency group from consistency group snapshots.
|
||
- Replication v2.1 support.
|
||
|
||
Preparation
|
||
~~~~~~~~~~~
|
||
|
||
This section contains instructions to prepare the Block Storage nodes to
|
||
use the EMC VNX driver. You should install the Navisphere CLI and ensure you
|
||
have correct zoning configurations.
|
||
|
||
Install Navisphere CLI
|
||
----------------------
|
||
|
||
Navisphere CLI needs to be installed on all Block Storage nodes within
|
||
an OpenStack deployment. You need to download different versions for
|
||
different platforms:
|
||
|
||
- For Ubuntu x64, DEB is available at `EMC OpenStack
|
||
Github <https://github.com/emc-openstack/naviseccli>`_.
|
||
|
||
- For all other variants of Linux, Navisphere CLI is available at
|
||
`Downloads for VNX2
|
||
Series <https://support.emc.com/downloads/36656_VNX2-Series>`_ or
|
||
`Downloads for VNX1
|
||
Series <https://support.emc.com/downloads/12781_VNX1-Series>`_.
|
||
|
||
Install Python library storops
|
||
------------------------------
|
||
|
||
``storops`` is a Python library that interacts with VNX array through
|
||
Navisphere CLI.
|
||
Use the following command to install the ``storops`` library:
|
||
|
||
.. code-block:: console
|
||
|
||
$ pip install storops
|
||
|
||
|
||
Check array software
|
||
--------------------
|
||
|
||
Make sure your have the following software installed for certain features:
|
||
|
||
+--------------------------------------------+---------------------+
|
||
| Feature | Software Required |
|
||
+============================================+=====================+
|
||
| All | ThinProvisioning |
|
||
+--------------------------------------------+---------------------+
|
||
| All | VNXSnapshots |
|
||
+--------------------------------------------+---------------------+
|
||
| FAST cache support | FASTCache |
|
||
+--------------------------------------------+---------------------+
|
||
| Create volume with type ``compressed`` | Compression |
|
||
+--------------------------------------------+---------------------+
|
||
| Create volume with type ``deduplicated`` | Deduplication |
|
||
+--------------------------------------------+---------------------+
|
||
|
||
**Required software**
|
||
|
||
You can check the status of your array software in the :guilabel:`Software`
|
||
page of :guilabel:`Storage System Properties`. Here is how it looks like:
|
||
|
||
.. figure:: ../../figures/emc-enabler.png
|
||
|
||
Network configuration
|
||
---------------------
|
||
|
||
For the FC Driver, FC zoning is properly configured between the hosts and
|
||
the VNX. Check :ref:`register-fc-port-with-vnx` for reference.
|
||
|
||
For the iSCSI Driver, make sure your VNX iSCSI port is accessible by
|
||
your hosts. Check :ref:`register-iscsi-port-with-vnx` for reference.
|
||
|
||
You can use ``initiator_auto_registration = True`` configuration to avoid
|
||
registering the ports manually. Check the detail of the configuration in
|
||
:ref:`emc-vnx-conf` for reference.
|
||
|
||
If you are trying to setup multipath, refer to :ref:`multipath-setup`.
|
||
|
||
|
||
.. _emc-vnx-conf:
|
||
|
||
Back-end configuration
|
||
~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
|
||
Make the following changes in the ``/etc/cinder/cinder.conf`` file.
|
||
|
||
Minimum configuration
|
||
---------------------
|
||
|
||
Here is a sample of minimum back-end configuration. See the following sections
|
||
for the detail of each option.
|
||
Set ``storage_protocol = iscsi`` if iSCSI protocol is used.
|
||
|
||
.. code-block:: ini
|
||
|
||
[DEFAULT]
|
||
enabled_backends = vnx_array1
|
||
|
||
[vnx_array1]
|
||
san_ip = 10.10.72.41
|
||
san_login = sysadmin
|
||
san_password = sysadmin
|
||
naviseccli_path = /opt/Navisphere/bin/naviseccli
|
||
volume_driver = cinder.volume.drivers.emc.vnx.driver.EMCVNXDriver
|
||
initiator_auto_registration = True
|
||
storage_protocol = fc
|
||
|
||
Multiple back-end configuration
|
||
-------------------------------
|
||
Here is a sample of a minimum back-end configuration. See following sections
|
||
for the detail of each option.
|
||
Set ``storage_protocol = iscsi`` if iSCSI protocol is used.
|
||
|
||
.. code-block:: ini
|
||
|
||
[DEFAULT]
|
||
enabled_backends = backendA, backendB
|
||
|
||
[backendA]
|
||
storage_vnx_pool_names = Pool_01_SAS, Pool_02_FLASH
|
||
san_ip = 10.10.72.41
|
||
storage_vnx_security_file_dir = /etc/secfile/array1
|
||
naviseccli_path = /opt/Navisphere/bin/naviseccli
|
||
volume_driver = cinder.volume.drivers.emc.vnx.driver.EMCVNXDriver
|
||
initiator_auto_registration = True
|
||
storage_protocol = fc
|
||
|
||
[backendB]
|
||
storage_vnx_pool_names = Pool_02_SAS
|
||
san_ip = 10.10.26.101
|
||
san_login = username
|
||
san_password = password
|
||
naviseccli_path = /opt/Navisphere/bin/naviseccli
|
||
volume_driver = cinder.volume.drivers.emc.vnx.driver.EMCVNXDriver
|
||
initiator_auto_registration = True
|
||
storage_protocol = fc
|
||
|
||
The value of the option ``storage_protocol`` can be either ``fc`` or ``iscsi``,
|
||
which is case insensitive.
|
||
|
||
For more details on multiple back ends, see `Configure multiple-storage
|
||
back ends <http://docs.openstack.org/admin-guide/blockstorage-multi-backend.html>`_
|
||
|
||
Required configurations
|
||
-----------------------
|
||
|
||
**IP of the VNX Storage Processors**
|
||
|
||
Specify SP A or SP B IP to connect:
|
||
|
||
.. code-block:: ini
|
||
|
||
san_ip = <IP of VNX Storage Processor>
|
||
|
||
**VNX login credentials**
|
||
|
||
There are two ways to specify the credentials.
|
||
|
||
- Use plain text username and password.
|
||
|
||
Supply for plain username and password:
|
||
|
||
.. code-block:: ini
|
||
|
||
san_login = <VNX account with administrator role>
|
||
san_password = <password for VNX account>
|
||
storage_vnx_authentication_type = global
|
||
|
||
Valid values for ``storage_vnx_authentication_type`` are: ``global``
|
||
(default), ``local``, and ``ldap``.
|
||
|
||
- Use Security file.
|
||
|
||
This approach avoids the plain text password in your cinder
|
||
configuration file. Supply a security file as below:
|
||
|
||
.. code-block:: ini
|
||
|
||
storage_vnx_security_file_dir = <path to security file>
|
||
|
||
Check Unisphere CLI user guide or :ref:`authenticate-by-security-file`
|
||
for how to create a security file.
|
||
|
||
**Path to your Unisphere CLI**
|
||
|
||
Specify the absolute path to your naviseccli:
|
||
|
||
.. code-block:: ini
|
||
|
||
naviseccli_path = /opt/Navisphere/bin/naviseccli
|
||
|
||
**Driver's storage protocol**
|
||
|
||
- For the FC Driver, add the following option:
|
||
|
||
.. code-block:: ini
|
||
|
||
volume_driver = cinder.volume.drivers.emc.vnx.driver.EMCVNXDriver
|
||
storage_protocol = fc
|
||
|
||
- For iSCSI Driver, add the following option:
|
||
|
||
.. code-block:: ini
|
||
|
||
volume_driver = cinder.volume.drivers.emc.vnx.driver.EMCVNXDriver
|
||
storage_protocol = iscsi
|
||
|
||
Optional configurations
|
||
~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
VNX pool names
|
||
--------------
|
||
|
||
Specify the list of pools to be managed, separated by commas. They should
|
||
already exist in VNX.
|
||
|
||
.. code-block:: ini
|
||
|
||
storage_vnx_pool_names = pool 1, pool 2
|
||
|
||
If this value is not specified, all pools of the array will be used.
|
||
|
||
**Initiator auto registration**
|
||
|
||
When ``initiator_auto_registration`` is set to ``True``, the driver will
|
||
automatically register initiators to all working target ports of the VNX array
|
||
during volume attaching (The driver will skip those initiators that have
|
||
already been registered) if the option ``io_port_list`` is not specified in
|
||
the ``cinder.conf`` file.
|
||
|
||
If the user wants to register the initiators with some specific ports but not
|
||
register with the other ports, this functionality should be disabled.
|
||
|
||
When a comma-separated list is given to ``io_port_list``, the driver will only
|
||
register the initiator to the ports specified in the list and only return
|
||
target port(s) which belong to the target ports in the ``io_port_list`` instead
|
||
of all target ports.
|
||
|
||
- Example for FC ports:
|
||
|
||
.. code-block:: ini
|
||
|
||
io_port_list = a-1,B-3
|
||
|
||
``a`` or ``B`` is *Storage Processor*, number ``1`` and ``3`` are
|
||
*Port ID*.
|
||
|
||
- Example for iSCSI ports:
|
||
|
||
.. code-block:: ini
|
||
|
||
io_port_list = a-1-0,B-3-0
|
||
|
||
``a`` or ``B`` is *Storage Processor*, the first numbers ``1`` and ``3`` are
|
||
*Port ID* and the second number ``0`` is *Virtual Port ID*
|
||
|
||
.. note::
|
||
|
||
- Rather than de-registered, the registered ports will be simply
|
||
bypassed whatever they are in ``io_port_list`` or not.
|
||
|
||
- The driver will raise an exception if ports in ``io_port_list``
|
||
do not exist in VNX during startup.
|
||
|
||
Force delete volumes in storage group
|
||
-------------------------------------
|
||
|
||
Some ``available`` volumes may remain in storage group on the VNX array due to
|
||
some OpenStack timeout issue. But the VNX array do not allow the user to delete
|
||
the volumes which are in storage group. Option
|
||
``force_delete_lun_in_storagegroup`` is introduced to allow the user to delete
|
||
the ``available`` volumes in this tricky situation.
|
||
|
||
When ``force_delete_lun_in_storagegroup`` is set to ``True`` in the back-end
|
||
section, the driver will move the volumes out of the storage groups and then
|
||
delete them if the user tries to delete the volumes that remain in the storage
|
||
group on the VNX array.
|
||
|
||
The default value of ``force_delete_lun_in_storagegroup`` is ``False``.
|
||
|
||
Over subscription in thin provisioning
|
||
--------------------------------------
|
||
|
||
Over subscription allows that the sum of all volume's capacity (provisioned
|
||
capacity) to be larger than the pool's total capacity.
|
||
|
||
``max_over_subscription_ratio`` in the back-end section is the ratio of
|
||
provisioned capacity over total capacity.
|
||
|
||
The default value of ``max_over_subscription_ratio`` is 20.0, which means
|
||
the provisioned capacity can be 20 times of the total capacity.
|
||
If the value of this ratio is set larger than 1.0, the provisioned
|
||
capacity can exceed the total capacity.
|
||
|
||
Storage group automatic deletion
|
||
--------------------------------
|
||
|
||
For volume attaching, the driver has a storage group on VNX for each compute
|
||
node hosting the vm instances which are going to consume VNX Block Storage
|
||
(using compute node's host name as storage group's name). All the volumes
|
||
attached to the VM instances in a Compute node will be put into the storage
|
||
group. If ``destroy_empty_storage_group`` is set to ``True``, the driver will
|
||
remove the empty storage group after its last volume is detached. For data
|
||
safety, it does not suggest to set ``destroy_empty_storage_group=True`` unless
|
||
the VNX is exclusively managed by one Block Storage node because consistent
|
||
``lock_path`` is required for operation synchronization for this behavior.
|
||
|
||
Initiator auto deregistration
|
||
-----------------------------
|
||
|
||
Enabling storage group automatic deletion is the precondition of this function.
|
||
If ``initiator_auto_deregistration`` is set to ``True`` is set, the driver will
|
||
deregister all FC and iSCSI initiators of the host after its storage group is
|
||
deleted.
|
||
|
||
FC SAN auto zoning
|
||
------------------
|
||
|
||
The EMC VNX driver supports FC SAN auto zoning when ``ZoneManager`` is
|
||
configured and ``zoning_mode`` is set to ``fabric`` in ``cinder.conf``.
|
||
For ZoneManager configuration, refer to :doc:`../fc-zoning`.
|
||
|
||
Volume number threshold
|
||
-----------------------
|
||
|
||
In VNX, there is a limitation on the number of pool volumes that can be created
|
||
in the system. When the limitation is reached, no more pool volumes can be
|
||
created even if there is remaining capacity in the storage pool. In other
|
||
words, if the scheduler dispatches a volume creation request to a back end that
|
||
has free capacity but reaches the volume limitation, the creation fails.
|
||
|
||
The default value of ``check_max_pool_luns_threshold`` is ``False``. When
|
||
``check_max_pool_luns_threshold=True``, the pool-based back end will check the
|
||
limit and will report 0 free capacity to the scheduler if the limit is reached.
|
||
So the scheduler will be able to skip this kind of pool-based back end that
|
||
runs out of the pool volume number.
|
||
|
||
iSCSI initiators
|
||
----------------
|
||
|
||
``iscsi_initiators`` is a dictionary of IP addresses of the iSCSI
|
||
initiator ports on OpenStack Compute and Block Storage nodes which want to
|
||
connect to VNX via iSCSI. If this option is configured, the driver will
|
||
leverage this information to find an accessible iSCSI target portal for the
|
||
initiator when attaching volume. Otherwise, the iSCSI target portal will be
|
||
chosen in a relative random way.
|
||
|
||
.. note::
|
||
|
||
This option is only valid for iSCSI driver.
|
||
|
||
Here is an example. VNX will connect ``host1`` with ``10.0.0.1`` and
|
||
``10.0.0.2``. And it will connect ``host2`` with ``10.0.0.3``.
|
||
|
||
The key name (``host1`` in the example) should be the output of
|
||
:command:`hostname` command.
|
||
|
||
.. code-block:: ini
|
||
|
||
iscsi_initiators = {"host1":["10.0.0.1", "10.0.0.2"],"host2":["10.0.0.3"]}
|
||
|
||
Default timeout
|
||
---------------
|
||
|
||
Specify the timeout in minutes for operations like LUN migration, LUN creation,
|
||
etc. For example, LUN migration is a typical long running operation, which
|
||
depends on the LUN size and the load of the array. An upper bound in the
|
||
specific deployment can be set to avoid unnecessary long wait.
|
||
|
||
The default value for this option is ``infinite``.
|
||
|
||
.. code-block:: ini
|
||
|
||
default_timeout = 60
|
||
|
||
Max LUNs per storage group
|
||
--------------------------
|
||
|
||
The ``max_luns_per_storage_group`` specify the maximum number of LUNs in a
|
||
storage group. Default value is 255. It is also the maximum value supported by
|
||
VNX.
|
||
|
||
Ignore pool full threshold
|
||
--------------------------
|
||
|
||
If ``ignore_pool_full_threshold`` is set to ``True``, driver will force LUN
|
||
creation even if the full threshold of pool is reached. Default to ``False``.
|
||
|
||
Extra spec options
|
||
~~~~~~~~~~~~~~~~~~
|
||
|
||
Extra specs are used in volume types created in Block Storage as the preferred
|
||
property of the volume.
|
||
|
||
The Block Storage scheduler will use extra specs to find the suitable back end
|
||
for the volume and the Block Storage driver will create the volume based on the
|
||
properties specified by the extra spec.
|
||
|
||
Use the following command to create a volume type:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume type create demoVolumeType
|
||
|
||
Use the following command to update the extra spec of a volume type:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume type set --property provisioning:type=thin thick_provisioning_support='<is> True' demoVolumeType
|
||
|
||
The following sections describe the VNX extra keys.
|
||
|
||
Provisioning type
|
||
-----------------
|
||
|
||
- Key: ``provisioning:type``
|
||
|
||
- Possible Values:
|
||
|
||
- ``thick``
|
||
|
||
Volume is fully provisioned.
|
||
|
||
Run the following commands to create a ``thick`` volume type:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume type create ThickVolumeType
|
||
$ openstack volume type set --property provisioning:type=thick thick_provisioning_support='<is> True' ThickVolumeType
|
||
|
||
- ``thin``
|
||
|
||
Volume is virtually provisioned.
|
||
|
||
Run the following commands to create a ``thin`` volume type:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume type create ThinVolumeType
|
||
$ openstack volume type set --property provisioning:type=thin thin_provisioning_support='<is> True' ThinVolumeType
|
||
|
||
- ``deduplicated``
|
||
|
||
Volume is ``thin`` and deduplication is enabled. The administrator shall
|
||
go to VNX to configure the system level deduplication settings. To
|
||
create a deduplicated volume, the VNX Deduplication license must be
|
||
activated on VNX, and specify ``deduplication_support=True`` to let Block
|
||
Storage scheduler find the proper volume back end.
|
||
|
||
Run the following commands to create a ``deduplicated`` volume type:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume type create DeduplicatedVolumeType
|
||
$ openstack volume type set --property provisioning:type=deduplicated deduplicated_support='<is> True' DeduplicatedVolumeType
|
||
|
||
- ``compressed``
|
||
|
||
Volume is ``thin`` and compression is enabled. The administrator shall go
|
||
to the VNX to configure the system level compression settings. To create
|
||
a compressed volume, the VNX Compression license must be activated on
|
||
VNX, and use ``compression_support=True`` to let Block Storage scheduler
|
||
find a volume back end. VNX does not support creating snapshots on a
|
||
compressed volume.
|
||
|
||
Run the following commands to create a ``compressed`` volume type:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume type create CompressedVolumeType
|
||
$ openstack volume type set --property provisioning:type=compressed compression_support='<is> True' CompressedVolumeType
|
||
|
||
- Default: ``thick``
|
||
|
||
.. note::
|
||
|
||
``provisioning:type`` replaces the old spec key ``storagetype:provisioning``.
|
||
The latter one is obsolete since the *Mitaka* release.
|
||
|
||
Storage tiering support
|
||
-----------------------
|
||
|
||
- Key: ``storagetype:tiering``
|
||
- Possible values:
|
||
|
||
- ``StartHighThenAuto``
|
||
- ``Auto``
|
||
- ``HighestAvailable``
|
||
- ``LowestAvailable``
|
||
- ``NoMovement``
|
||
|
||
- Default: ``StartHighThenAuto``
|
||
|
||
VNX supports fully automated storage tiering which requires the FAST license
|
||
activated on the VNX. The OpenStack administrator can use the extra spec key
|
||
``storagetype:tiering`` to set the tiering policy of a volume and use the key
|
||
``fast_support='<is> True'`` to let Block Storage scheduler find a volume back
|
||
end which manages a VNX with FAST license activated. Here are the five
|
||
supported values for the extra spec key ``storagetype:tiering``:
|
||
|
||
Run the following commands to create a volume type with tiering policy:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume type create ThinVolumeOnAutoTier
|
||
$ openstack volume type set --property provisioning:type=thin storagetype:tiering=Auto fast_support='<is> True' ThinVolumeOnAutoTier
|
||
|
||
.. note::
|
||
|
||
The tiering policy cannot be applied to a deduplicated volume. Tiering
|
||
policy of the deduplicated LUN align with the settings of the pool.
|
||
|
||
FAST cache support
|
||
------------------
|
||
|
||
- Key: ``fast_cache_enabled``
|
||
|
||
- Possible values:
|
||
|
||
- ``True``
|
||
|
||
- ``False``
|
||
|
||
- Default: ``False``
|
||
|
||
VNX has FAST Cache feature which requires the FAST Cache license activated on
|
||
the VNX. Volume will be created on the backend with FAST cache enabled when
|
||
``<is> True`` is specified.
|
||
|
||
Pool name
|
||
---------
|
||
|
||
- Key: ``pool_name``
|
||
|
||
- Possible values: name of the storage pool managed by cinder
|
||
|
||
- Default: None
|
||
|
||
If the user wants to create a volume on a certain storage pool in a back end
|
||
that manages multiple pools, a volume type with a extra spec specified storage
|
||
pool should be created first, then the user can use this volume type to create
|
||
the volume.
|
||
|
||
Run the following commands to create the volume type:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume type create HighPerf
|
||
$ openstack volume type set --property pool_name=Pool_02_SASFLASH volume_backend_name=vnx_41 HighPerf
|
||
|
||
Obsolete extra specs
|
||
--------------------
|
||
|
||
.. note::
|
||
|
||
*DO NOT* use the following obsolete extra spec keys:
|
||
|
||
- ``storagetype:provisioning``
|
||
- ``storagetype:pool``
|
||
|
||
|
||
Advanced features
|
||
~~~~~~~~~~~~~~~~~
|
||
|
||
Snap copy
|
||
---------
|
||
|
||
- Metadata Key: ``snapcopy``
|
||
- Possible Values:
|
||
|
||
- ``True`` or ``true``
|
||
- ``False`` or ``false``
|
||
|
||
- Default: `False`
|
||
|
||
VNX driver supports snap copy which accelerates the process for
|
||
creating a copied volume.
|
||
|
||
By default, the driver will do full data copy when creating a
|
||
volume from a snapshot or cloning a volume. This is time-consuming, especially
|
||
for large volumes. When snap copy is used, driver creates a
|
||
snapshot and mounts it as a volume for the 2 kinds of operations which will be
|
||
instant even for large volumes.
|
||
|
||
To enable this functionality, append ``--metadata snapcopy=True``
|
||
when creating cloned volume or creating volume from snapshot.
|
||
|
||
.. code-block:: console
|
||
|
||
$ cinder create --source-volid <source-void> --name "cloned_volume" --metadata snapcopy=True
|
||
|
||
Or
|
||
|
||
.. code-block:: console
|
||
|
||
$ cinder create --snapshot-id <snapshot-id> --name "vol_from_snapshot" --metadata snapcopy=True
|
||
|
||
|
||
The newly created volume is a snap copy instead of
|
||
a full copy. If a full copy is needed, retype or migrate can be used
|
||
to convert the snap-copy volume to a full-copy volume which may be
|
||
time-consuming.
|
||
|
||
You can determine whether the volume is a snap-copy volume or not by
|
||
showing its metadata. If the ``snapcopy`` in metadata is ``True`` or ``true``,
|
||
the volume is a snap-copy volume. Otherwise, it is a full-copy volume.
|
||
|
||
.. code-block:: console
|
||
|
||
$ cinder metadata-show <volume>
|
||
|
||
**Constraints**
|
||
|
||
- The number of snap-copy volumes created from a single source volume is
|
||
limited to 255 at one point in time.
|
||
- The source volume which has snap-copy volume can not be deleted or migrated.
|
||
- snapcopy volume will be change to full-copy volume after host-assisted or
|
||
storage-assisted migration.
|
||
- snapcopy volume can not be added to consisgroup because of VNX limitation.
|
||
|
||
Efficient non-disruptive volume backup
|
||
--------------------------------------
|
||
|
||
The default implementation in Block Storage for non-disruptive volume backup is
|
||
not efficient since a cloned volume will be created during backup.
|
||
|
||
The approach of efficient backup is to create a snapshot for the volume and
|
||
connect this snapshot (a mount point in VNX) to the Block Storage host for
|
||
volume backup. This eliminates migration time involved in volume clone.
|
||
|
||
**Constraints**
|
||
|
||
- Backup creation for a snap-copy volume is not allowed if the volume
|
||
status is ``in-use`` since snapshot cannot be taken from this volume.
|
||
|
||
Configurable migration rate
|
||
---------------------------
|
||
|
||
VNX cinder driver is leveraging the LUN migration from the VNX. LUN migration
|
||
is involved in cloning, migrating, retyping, and creating volume from snapshot.
|
||
When admin set ``migrate_rate`` in volume's ``metadata``, VNX driver can start
|
||
migration with specified rate. The available values for the ``migrate_rate``
|
||
are ``high``, ``asap``, ``low`` and ``medium``.
|
||
|
||
The following is an example to set ``migrate_rate`` to ``asap``:
|
||
|
||
.. code-block:: console
|
||
|
||
$ cinder metadata <volume-id> set migrate_rate=asap
|
||
|
||
After set, any cinder volume operations involving VNX LUN migration will
|
||
take the value as the migration rate. To restore the migration rate to
|
||
default, unset the metadata as following:
|
||
|
||
.. code-block:: console
|
||
|
||
$ cinder metadata <volume-id> unset migrate_rate
|
||
|
||
.. note::
|
||
|
||
Do not use the ``asap`` migration rate when the system is in production, as the normal
|
||
host I/O may be interrupted. Use asap only when the system is offline
|
||
(free of any host-level I/O).
|
||
|
||
Replication v2.1 support
|
||
------------------------
|
||
|
||
Cinder introduces Replication v2.1 support in Mitaka, it supports
|
||
fail-over and fail-back replication for specific back end. In VNX cinder
|
||
driver, **MirrorView** is used to set up replication for the volume.
|
||
|
||
To enable this feature, you need to set configuration in ``cinder.conf`` as
|
||
below:
|
||
|
||
.. code-block:: ini
|
||
|
||
replication_device = backend_id:<secondary VNX serial number>,
|
||
san_ip:192.168.1.2,
|
||
san_login:admin,
|
||
san_password:admin,
|
||
naviseccli_path:/opt/Navisphere/bin/naviseccli,
|
||
storage_vnx_authentication_type:global,
|
||
storage_vnx_security_file_dir:
|
||
|
||
Currently, only synchronized mode **MirrorView** is supported, and one volume
|
||
can only have 1 secondary storage system. Therefore, you can have only one
|
||
``replication_device`` presented in driver configuration section.
|
||
|
||
To create a replication enabled volume, you need to create a volume type:
|
||
|
||
.. code-block:: console
|
||
|
||
$ cinder type-create replication-type
|
||
$ cinder type-key replication-type set replication_enabled="<is> True"
|
||
|
||
And then create volume with above volume type:
|
||
|
||
.. code-block:: console
|
||
|
||
$ cinder create --volume-type replication-type --name replication-volume 1
|
||
|
||
**Supported operations**
|
||
|
||
- Create volume
|
||
- Create cloned volume
|
||
- Create volume from snapshot
|
||
- Fail-over volume:
|
||
|
||
.. code-block:: console
|
||
|
||
$ cinder failover-host --backend_id <secondary VNX serial number> <hostname>
|
||
|
||
- Fail-back volume:
|
||
|
||
.. code-block:: console
|
||
|
||
$ cinder failover-host --backend_id default <hostname>
|
||
|
||
**Requirements**
|
||
|
||
- 2 VNX systems must be in same domain.
|
||
- For iSCSI MirrorView, user needs to setup iSCSI connection before enable
|
||
replication in Cinder.
|
||
- For FC MirrorView, user needs to zone specific FC ports from 2
|
||
VNX system together.
|
||
- MirrorView Sync enabler( **MirrorView/S** ) installed on both systems.
|
||
- Write intent log enabled on both VNX systems.
|
||
|
||
For more information on how to configure, please refer to: `MirrorView-Knowledgebook:-Releases-30-–-33 <https://support.emc.com/docu32906_MirrorView-Knowledgebook:-Releases-30-%E2%80%93-33---A-Detailed-Review.pdf?language=en_US>`_
|
||
|
||
|
||
Best practice
|
||
~~~~~~~~~~~~~
|
||
|
||
.. _multipath-setup:
|
||
|
||
Multipath setup
|
||
---------------
|
||
|
||
Enabling multipath volume access is recommended for robust data access.
|
||
The major configuration includes:
|
||
|
||
#. Install ``multipath-tools``, ``sysfsutils`` and ``sg3-utils`` on the
|
||
nodes hosting Nova-Compute and Cinder-Volume services. Check
|
||
the operating system manual for the system distribution for specific
|
||
installation steps. For Red Hat based distributions, they should be
|
||
``device-mapper-multipath``, ``sysfsutils`` and ``sg3_utils``.
|
||
|
||
#. Specify ``use_multipath_for_image_xfer=true`` in the ``cinder.conf`` file
|
||
for each FC/iSCSI back end.
|
||
|
||
#. Specify ``iscsi_use_multipath=True`` in ``libvirt`` section of the
|
||
``nova.conf`` file. This option is valid for both iSCSI and FC driver.
|
||
|
||
For multipath-tools, here is an EMC recommended sample of
|
||
``/etc/multipath.conf`` file.
|
||
|
||
``user_friendly_names`` is not specified in the configuration and thus
|
||
it will take the default value ``no``. It is not recommended to set it
|
||
to ``yes`` because it may fail operations such as VM live migration.
|
||
|
||
.. code-block:: none
|
||
|
||
blacklist {
|
||
# Skip the files under /dev that are definitely not FC/iSCSI devices
|
||
# Different system may need different customization
|
||
devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*"
|
||
devnode "^hd[a-z][0-9]*"
|
||
devnode "^cciss!c[0-9]d[0-9]*[p[0-9]*]"
|
||
|
||
# Skip LUNZ device from VNX
|
||
device {
|
||
vendor "DGC"
|
||
product "LUNZ"
|
||
}
|
||
}
|
||
|
||
defaults {
|
||
user_friendly_names no
|
||
flush_on_last_del yes
|
||
}
|
||
|
||
devices {
|
||
# Device attributed for EMC CLARiiON and VNX series ALUA
|
||
device {
|
||
vendor "DGC"
|
||
product ".*"
|
||
product_blacklist "LUNZ"
|
||
path_grouping_policy group_by_prio
|
||
path_selector "round-robin 0"
|
||
path_checker emc_clariion
|
||
features "1 queue_if_no_path"
|
||
hardware_handler "1 alua"
|
||
prio alua
|
||
failback immediate
|
||
}
|
||
}
|
||
|
||
.. note::
|
||
|
||
When multipath is used in OpenStack, multipath faulty devices may
|
||
come out in Nova-Compute nodes due to different issues (`Bug
|
||
1336683 <https://bugs.launchpad.net/nova/+bug/1336683>`_ is a
|
||
typical example).
|
||
|
||
A solution to completely avoid faulty devices has not been found yet.
|
||
``faulty_device_cleanup.py`` mitigates this issue when VNX iSCSI storage is
|
||
used. Cloud administrators can deploy the script in all Nova-Compute nodes and
|
||
use a CRON job to run the script on each Nova-Compute node periodically so that
|
||
faulty devices will not stay too long. Refer to: `VNX faulty device
|
||
cleanup <https://github.com/emc-openstack/vnx-faulty-device-cleanup>`_ for
|
||
detailed usage and the script.
|
||
|
||
Restrictions and limitations
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
iSCSI port cache
|
||
----------------
|
||
|
||
EMC VNX iSCSI driver caches the iSCSI ports information, so that the user
|
||
should restart the ``cinder-volume`` service or wait for seconds (which is
|
||
configured by ``periodic_interval`` in the ``cinder.conf`` file) before any
|
||
volume attachment operation after changing the iSCSI port configurations.
|
||
Otherwise the attachment may fail because the old iSCSI port configurations
|
||
were used.
|
||
|
||
No extending for volume with snapshots
|
||
--------------------------------------
|
||
|
||
VNX does not support extending the thick volume which has a snapshot. If the
|
||
user tries to extend a volume which has a snapshot, the status of the volume
|
||
would change to ``error_extending``.
|
||
|
||
Limitations for deploying cinder on computer node
|
||
-------------------------------------------------
|
||
|
||
It is not recommended to deploy the driver on a compute node if ``cinder
|
||
upload-to-image --force True`` is used against an in-use volume. Otherwise,
|
||
``cinder upload-to-image --force True`` will terminate the data access of the
|
||
vm instance to the volume.
|
||
|
||
Storage group with host names in VNX
|
||
------------------------------------
|
||
|
||
When the driver notices that there is no existing storage group that has the
|
||
host name as the storage group name, it will create the storage group and also
|
||
add the compute node's or Block Storage node's registered initiators into the
|
||
storage group.
|
||
|
||
If the driver notices that the storage group already exists, it will assume
|
||
that the registered initiators have also been put into it and skip the
|
||
operations above for better performance.
|
||
|
||
It is recommended that the storage administrator does not create the storage
|
||
group manually and instead relies on the driver for the preparation. If the
|
||
storage administrator needs to create the storage group manually for some
|
||
special requirements, the correct registered initiators should be put into the
|
||
storage group as well (otherwise the following volume attaching operations will
|
||
fail).
|
||
|
||
EMC storage-assisted volume migration
|
||
-------------------------------------
|
||
|
||
EMC VNX driver supports storage-assisted volume migration, when the user starts
|
||
migrating with ``cinder migrate --force-host-copy False <volume_id> <host>`` or
|
||
``cinder migrate <volume_id> <host>``, cinder will try to leverage the VNX's
|
||
native volume migration functionality.
|
||
|
||
In following scenarios, VNX storage-assisted volume migration will not be
|
||
triggered:
|
||
|
||
- ``in-use`` volume migration between back ends with different storage
|
||
protocol, for example, FC and iSCSI.
|
||
- Volume is to be migrated across arrays.
|
||
|
||
Appendix
|
||
~~~~~~~~
|
||
|
||
.. _authenticate-by-security-file:
|
||
|
||
Authenticate by security file
|
||
-----------------------------
|
||
|
||
VNX credentials are necessary when the driver connects to the VNX system.
|
||
Credentials in ``global``, ``local`` and ``ldap`` scopes are supported. There
|
||
are two approaches to provide the credentials.
|
||
|
||
The recommended one is using the Navisphere CLI security file to provide the
|
||
credentials which can get rid of providing the plain text credentials in the
|
||
configuration file. Following is the instruction on how to do this.
|
||
|
||
#. Find out the Linux user id of the ``cinder-volume`` processes. Assuming the
|
||
``cinder-volume`` service is running by the account ``cinder``.
|
||
|
||
#. Run ``su`` as root user.
|
||
|
||
#. In ``/etc/passwd`` file, change
|
||
``cinder:x:113:120::/var/lib/cinder:/bin/false``
|
||
to ``cinder:x:113:120::/var/lib/cinder:/bin/bash`` (This temporary change is
|
||
to make step 4 work.)
|
||
|
||
#. Save the credentials on behalf of ``cinder`` user to a security file
|
||
(assuming the array credentials are ``admin/admin`` in ``global`` scope). In
|
||
the command below, the ``-secfilepath`` switch is used to specify the
|
||
location to save the security file.
|
||
|
||
.. code-block:: console
|
||
|
||
# su -l cinder -c '/opt/Navisphere/bin/naviseccli \
|
||
-AddUserSecurity -user admin -password admin -scope 0 -secfilepath <location>'
|
||
|
||
#. Change ``cinder:x:113:120::/var/lib/cinder:/bin/bash`` back to
|
||
``cinder:x:113:120::/var/lib/cinder:/bin/false`` in ``/etc/passwd`` file.
|
||
|
||
#. Remove the credentials options ``san_login``, ``san_password`` and
|
||
``storage_vnx_authentication_type`` from ``cinder.conf`` file. (normally
|
||
it is ``/etc/cinder/cinder.conf`` file). Add option
|
||
``storage_vnx_security_file_dir`` and set its value to the directory path of
|
||
your security file generated in the above step. Omit this option if
|
||
``-secfilepath`` is not used in the above step.
|
||
|
||
#. Restart the ``cinder-volume`` service to validate the change.
|
||
|
||
|
||
.. _register-fc-port-with-vnx:
|
||
|
||
Register FC port with VNX
|
||
-------------------------
|
||
|
||
This configuration is only required when ``initiator_auto_registration=False``.
|
||
|
||
To access VNX storage, the Compute nodes should be registered on VNX first if
|
||
initiator auto registration is not enabled.
|
||
|
||
To perform ``Copy Image to Volume`` and ``Copy Volume to Image`` operations,
|
||
the nodes running the ``cinder-volume`` service (Block Storage nodes) must be
|
||
registered with the VNX as well.
|
||
|
||
The steps mentioned below are for the compute nodes. Follow the same
|
||
steps for the Block Storage nodes also (The steps can be skipped if initiator
|
||
auto registration is enabled).
|
||
|
||
#. Assume ``20:00:00:24:FF:48:BA:C2:21:00:00:24:FF:48:BA:C2`` is the WWN of a
|
||
FC initiator port name of the compute node whose host name and IP are
|
||
``myhost1`` and ``10.10.61.1``. Register
|
||
``20:00:00:24:FF:48:BA:C2:21:00:00:24:FF:48:BA:C2`` in Unisphere:
|
||
|
||
#. Log in to :guilabel:`Unisphere`, go to
|
||
:menuselection:`FNM0000000000 > Hosts > Initiators`.
|
||
|
||
#. Refresh and wait until the initiator
|
||
``20:00:00:24:FF:48:BA:C2:21:00:00:24:FF:48:BA:C2`` with SP Port ``A-1``
|
||
appears.
|
||
|
||
#. Click the :guilabel:`Register` button, select :guilabel:`CLARiiON/VNX`
|
||
and enter the host name (which is the output of the :command:`hostname`
|
||
command) and IP address:
|
||
|
||
- Hostname: ``myhost1``
|
||
|
||
- IP: ``10.10.61.1``
|
||
|
||
- Click :guilabel:`Register`.
|
||
|
||
#. Then host ``10.10.61.1`` will appear under
|
||
:menuselection:`Hosts > Host List` as well.
|
||
|
||
#. Register the ``wwn`` with more ports if needed.
|
||
|
||
.. _register-iscsi-port-with-vnx:
|
||
|
||
Register iSCSI port with VNX
|
||
----------------------------
|
||
|
||
This configuration is only required when ``initiator_auto_registration=False``.
|
||
|
||
To access VNX storage, the compute nodes should be registered on VNX first if
|
||
initiator auto registration is not enabled.
|
||
|
||
To perform ``Copy Image to Volume`` and ``Copy Volume to Image`` operations,
|
||
the nodes running the ``cinder-volume`` service (Block Storage nodes) must be
|
||
registered with the VNX as well.
|
||
|
||
The steps mentioned below are for the compute nodes. Follow the
|
||
same steps for the Block Storage nodes also (The steps can be skipped if
|
||
initiator auto registration is enabled).
|
||
|
||
#. On the compute node with IP address ``10.10.61.1`` and host name ``myhost1``,
|
||
execute the following commands (assuming ``10.10.61.35`` is the iSCSI
|
||
target):
|
||
|
||
#. Start the iSCSI initiator service on the node:
|
||
|
||
.. code-block:: console
|
||
|
||
# /etc/init.d/open-iscsi start
|
||
|
||
#. Discover the iSCSI target portals on VNX:
|
||
|
||
.. code-block:: console
|
||
|
||
# iscsiadm -m discovery -t st -p 10.10.61.35
|
||
|
||
#. Change directory to ``/etc/iscsi`` :
|
||
|
||
.. code-block:: console
|
||
|
||
# cd /etc/iscsi
|
||
|
||
#. Find out the ``iqn`` of the node:
|
||
|
||
.. code-block:: console
|
||
|
||
# more initiatorname.iscsi
|
||
|
||
#. Log in to :guilabel:`VNX` from the compute node using the target
|
||
corresponding to the SPA port:
|
||
|
||
.. code-block:: console
|
||
|
||
# iscsiadm -m node -T iqn.1992-04.com.emc:cx.apm01234567890.a0 -p 10.10.61.35 -l
|
||
|
||
#. Assume ``iqn.1993-08.org.debian:01:1a2b3c4d5f6g`` is the initiator name of
|
||
the compute node. Register ``iqn.1993-08.org.debian:01:1a2b3c4d5f6g`` in
|
||
Unisphere:
|
||
|
||
#. Log in to :guilabel:`Unisphere`, go to
|
||
:menuselection:`FNM0000000000 > Hosts > Initiators`.
|
||
|
||
#. Refresh and wait until the initiator
|
||
``iqn.1993-08.org.debian:01:1a2b3c4d5f6g`` with SP Port ``A-8v0``
|
||
appears.
|
||
|
||
#. Click the :guilabel:`Register` button, select :guilabel:`CLARiiON/VNX`
|
||
and enter the host name
|
||
(which is the output of the :command:`hostname` command) and IP address:
|
||
|
||
- Hostname: ``myhost1``
|
||
|
||
- IP: ``10.10.61.1``
|
||
|
||
- Click :guilabel:`Register`.
|
||
|
||
#. Then host ``10.10.61.1`` will appear under
|
||
:menuselection:`Hosts > Host List` as well.
|
||
|
||
#. Log out :guilabel:`iSCSI` on the node:
|
||
|
||
.. code-block:: console
|
||
|
||
# iscsiadm -m node -u
|
||
|
||
#. Log in to :guilabel:`VNX` from the compute node using the target
|
||
corresponding to the SPB port:
|
||
|
||
.. code-block:: console
|
||
|
||
# iscsiadm -m node -T iqn.1992-04.com.emc:cx.apm01234567890.b8 -p 10.10.61.36 -l
|
||
|
||
#. In ``Unisphere``, register the initiator with the SPB port.
|
||
|
||
#. Log out :guilabel:`iSCSI` on the node:
|
||
|
||
.. code-block:: console
|
||
|
||
# iscsiadm -m node -u
|
||
|
||