.. _cinder-hpexp:
.. list-table:: Description of HPE XP volume driver configuration options
:header-rows: 1
:class: config-ref-table
* - Configuration option = Default value
- Description
* - **[DEFAULT]**
-
* - ``hpexp_async_copy_check_interval`` = ``10``
- (IntOpt) Interval to check copy asynchronously
* - ``hpexp_compute_target_ports`` = ``None``
- (ListOpt) Target port names of compute node for host group or iSCSI target
* - ``hpexp_copy_check_interval`` = ``3``
- (IntOpt) Interval to check copy
* - ``hpexp_copy_speed`` = ``3``
- (IntOpt) Copy speed of storage system
* - ``hpexp_default_copy_method`` = ``FULL``
- (StrOpt) Default copy method of storage system. There are two valid values: "FULL" specifies that a full copy; "THIN" specifies that a thin copy. Default value is "FULL"
* - ``hpexp_group_request`` = ``False``
- (BoolOpt) Request for creating host group or iSCSI target
* - ``hpexp_horcm_add_conf`` = ``True``
- (BoolOpt) Add to HORCM configuration
* - ``hpexp_horcm_name_only_discovery`` = ``False``
- (BoolOpt) Only discover a specific name of host group or iSCSI target
* - ``hpexp_horcm_numbers`` = ``200, 201``
- (ListOpt) Instance numbers for HORCM
* - ``hpexp_horcm_resource_name`` = ``meta_resource``
- (StrOpt) Resource group name of storage system for HORCM
* - ``hpexp_horcm_user`` = ``None``
- (StrOpt) Username of storage system for HORCM
* - ``hpexp_ldev_range`` = ``None``
- (StrOpt) Logical device range of storage system
* - ``hpexp_pool`` = ``None``
- (StrOpt) Pool of storage system
* - ``hpexp_storage_cli`` = ``None``
- (StrOpt) Type of storage command line interface
* - ``hpexp_storage_id`` = ``None``
- (StrOpt) ID of storage system
* - ``hpexp_target_ports`` = ``None``
- (ListOpt) Target port names for host group or iSCSI target
* - ``hpexp_thin_pool`` = ``None``
- (StrOpt) Thin pool of storage system
* - ``hpexp_zoning_request`` = ``False``
- (BoolOpt) Request for FC Zone creating host group