EMC VNX driver
|
|
==============
|
|
|
|
EMC VNX driver consists of EMCCLIISCSIDriver and EMCCLIFCDriver, and supports
|
|
both iSCSI and FC protocol. ``EMCCLIISCSIDriver`` (VNX iSCSI driver) and
|
|
``EMCCLIFCDriver`` (VNX FC driver) are separately based on the ``ISCSIDriver``
|
|
and ``FCDriver`` defined in the Block Storage service.
|
|
|
|
The VNX iSCSI driver and VNX FC driver perform the volume operations by
|
|
executing Navisphere CLI (NaviSecCLI) which is a command-line interface used
|
|
for management, diagnostics, and reporting functions for VNX.
|
|
|
|
System requirements
|
|
~~~~~~~~~~~~~~~~~~~
|
|
|
|
- VNX Operational Environment for Block version 5.32 or higher.
|
|
|
|
- VNX Snapshot and Thin Provisioning license should be activated for VNX.
|
|
|
|
- Navisphere CLI v7.32 or higher is installed along with the driver.
|
|
|
|
Supported operations
|
|
~~~~~~~~~~~~~~~~~~~~
|
|
|
|
- Create, delete, attach, and detach volumes.
|
|
- Create, list, and delete volume snapshots.
|
|
- Create a volume from a snapshot.
|
|
- Copy an image to a volume.
|
|
- Clone a volume.
|
|
- Extend a volume.
|
|
- Migrate a volume.
|
|
- Retype a volume.
|
|
- Get volume statistics.
|
|
- Create and delete consistency groups.
|
|
- Create, list, and delete consistency group snapshots.
|
|
- Modify consistency groups.
|
|
- Efficient non-disruptive volume backup.
|
|
|
|
Preparation
|
|
~~~~~~~~~~~
|
|
|
|
This section contains instructions to prepare the Block Storage nodes to
|
|
use the EMC VNX driver. You install the Navisphere CLI, install the
|
|
driver, ensure you have correct zoning configurations, and register the
|
|
driver.
|
|
|
|
Install Navisphere CLI
|
|
----------------------
|
|
|
|
Navisphere CLI needs to be installed on all Block Storage nodes within
|
|
an OpenStack deployment. You need to download different versions for
|
|
different platforms:
|
|
|
|
- For Ubuntu x64, DEB is available at `EMC OpenStack
|
|
Github <https://github.com/emc-openstack/naviseccli>`__.
|
|
|
|
- For all other variants of Linux, Navisphere CLI is available at
|
|
`Downloads for VNX2
|
|
Series <https://support.emc.com/downloads/36656_VNX2-Series>`__ or
|
|
`Downloads for VNX1
|
|
Series <https://support.emc.com/downloads/12781_VNX1-Series>`__.
|
|
|
|
- After installation, set the security level of Navisphere CLI to low:
|
|
|
|
.. code-block:: console
|
|
|
|
$ /opt/Navisphere/bin/naviseccli security -certificate -setLevel low
|
|
|
|
Check array software
|
|
--------------------
|
|
|
|
Make sure your have the following software installed for certain features:
|
|
|
|
+--------------------------------------------+---------------------+
|
|
| Feature | Software Required |
|
|
+============================================+=====================+
|
|
| All | ThinProvisioning |
|
|
+--------------------------------------------+---------------------+
|
|
| All | VNXSnapshots |
|
|
+--------------------------------------------+---------------------+
|
|
| FAST cache support | FASTCache |
|
|
+--------------------------------------------+---------------------+
|
|
| Create volume with type ``compressed`` | Compression |
|
|
+--------------------------------------------+---------------------+
|
|
| Create volume with type ``deduplicated`` | Deduplication |
|
|
+--------------------------------------------+---------------------+
|
|
|
|
**Required software**
|
|
|
|
You can check the status of your array software in the :guilabel:`Software`
|
|
page of :guilabel:`Storage System Properties`. Here is how it looks like:
|
|
|
|
.. figure:: ../../figures/emc-enabler.png
|
|
|
|
Network configuration
|
|
---------------------
|
|
|
|
For the FC Driver, FC zoning is properly configured between the hosts and
|
|
the VNX. Check :ref:`register-fc-port-with-vnx` for reference.
|
|
|
|
For the iSCSI Driver, make sure your VNX iSCSI port is accessible by
|
|
your hosts. Check :ref:`register-iscsi-port-with-vnx` for reference.
|
|
|
|
You can use ``initiator_auto_registration = True`` configuration to avoid
|
|
registering the ports manually. Check the detail of the configuration in
|
|
:ref:`emc-vnx-conf` for reference.
|
|
|
|
If you are trying to setup multipath, refer to :ref:`multipath-setup`.
|
|
|
|
|
|
.. _emc-vnx-conf:
|
|
|
|
Back-end configuration
|
|
~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
|
Make the following changes in the ``/etc/cinder/cinder.conf`` file.
|
|
|
|
Minimum configuration
|
|
---------------------
|
|
|
|
Here is a sample of a minimum back-end configuration. See the following
|
|
sections for the detail of each option. Replace ``EMCCLIFCDriver``
|
|
with ``EMCCLIISCSIDriver`` if you are using the iSCSI driver.
|
|
|
|
.. code-block:: ini
|
|
|
|
[DEFAULT]
|
|
enabled_backends = vnx_array1
|
|
|
|
[vnx_array1]
|
|
san_ip = 10.10.72.41
|
|
san_login = sysadmin
|
|
san_password = sysadmin
|
|
naviseccli_path = /opt/Navisphere/bin/naviseccli
|
|
volume_driver = cinder.volume.drivers.emc.emc_cli_fc.EMCCLIFCDriver
|
|
initiator_auto_registration = True
|
|
|
|
Multiple back-end configuration
|
|
-------------------------------
|
|
|
|
Here is a sample of a multiple back-end configuration. See the following
|
|
sections for the detail of each option. Replace ``EMCCLIFCDriver``
|
|
with ``EMCCLIISCSIDriver`` if you are using the iSCSI driver.
|
|
|
|
.. code-block:: ini
|
|
|
|
[DEFAULT]
|
|
enabled_backends = backendA, backendB
|
|
|
|
[backendA]
|
|
storage_vnx_pool_names = Pool_01_SAS, Pool_02_FLASH
|
|
san_ip = 10.10.72.41
|
|
storage_vnx_security_file_dir = /etc/secfile/array1
|
|
naviseccli_path = /opt/Navisphere/bin/naviseccli
|
|
volume_driver = cinder.volume.drivers.emc.emc_cli_fc.EMCCLIFCDriver
|
|
initiator_auto_registration = True
|
|
|
|
[backendB]
|
|
storage_vnx_pool_names = Pool_02_SAS
|
|
san_ip = 10.10.26.101
|
|
san_login = username
|
|
san_password = password
|
|
naviseccli_path = /opt/Navisphere/bin/naviseccli
|
|
volume_driver = cinder.volume.drivers.emc.emc_cli_fc.EMCCLIFCDriver
|
|
initiator_auto_registration = True
|
|
|
|
For more details on multi-backends, see `OpenStack Cloud Administration Guide
|
|
<http://docs.openstack.org/admin-guide-cloud/index.html>`__
|
|
|
|
Required configurations
|
|
-----------------------
|
|
|
|
**IP of the VNX Storage Processors**
|
|
|
|
Specify the SP A and SP B IP to connect:
|
|
|
|
.. code-block:: ini
|
|
|
|
san_ip = <IP of VNX Storage Processor A>
|
|
san_secondary_ip = <IP of VNX Storage Processor B>
|
|
|
|
**VNX login credentials**
|
|
|
|
There are two ways to specify the credentials.
|
|
|
|
- Use plain text username and password.
|
|
|
|
Supply for plain username and password:
|
|
|
|
.. code-block:: ini
|
|
|
|
san_login = <VNX account with administrator role>
|
|
san_password = <password for VNX account>
|
|
storage_vnx_authentication_type = global
|
|
|
|
Valid values for ``storage_vnx_authentication_type`` are: ``global``
|
|
(default), ``local``, and ``ldap``.
|
|
|
|
- Use Security file.
|
|
|
|
This approach avoids the plain text password in your cinder
|
|
configuration file. Supply a security file as below:
|
|
|
|
.. code-block:: ini
|
|
|
|
storage_vnx_security_file_dir = <path to security file>
|
|
|
|
Check Unisphere CLI user guide or :ref:`authenticate-by-security-file`
|
|
for how to create a security file.
|
|
|
|
**Path to your Unisphere CLI**
|
|
|
|
Specify the absolute path to your naviseccli:
|
|
|
|
.. code-block:: ini
|
|
|
|
naviseccli_path = /opt/Navisphere/bin/naviseccli
|
|
|
|
**Driver name**
|
|
|
|
- For the FC Driver, add the following option:
|
|
|
|
.. code-block:: ini
|
|
|
|
volume_driver = cinder.volume.drivers.emc.emc_cli_fc.EMCCLIFCDriver
|
|
|
|
- For iSCSI Driver, add the following option:
|
|
|
|
.. code-block:: ini
|
|
|
|
volume_driver = cinder.volume.drivers.emc.emc_cli_iscsi.EMCCLIISCSIDriver
|
|
|
|
Optional configurations
|
|
~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
VNX pool names
|
|
--------------
|
|
|
|
Specify the list of pools to be managed, separated by commas. They should
|
|
already exist in VNX.
|
|
|
|
.. code-block:: ini
|
|
|
|
storage_vnx_pool_names = pool 1, pool 2
|
|
|
|
If this value is not specified, all pools of the array will be used.
|
|
|
|
**Initiator auto registration**
|
|
|
|
When ``initiator_auto_registration`` is set to ``True``, the driver will
|
|
automatically register initiators to all working target ports of the VNX array
|
|
during volume attaching (The driver will skip those initiators that have
|
|
already been registered) if the option ``io_port_list`` is not specified in
|
|
the ``cinder.conf`` file.
|
|
|
|
If the user wants to register the initiators with some specific ports but not
|
|
register with the other ports, this functionality should be disabled.
|
|
|
|
When a comma-separated list is given to ``io_port_list``, the driver will only
|
|
register the initiator to the ports specified in the list and only return
|
|
target port(s) which belong to the target ports in the ``io_port_list`` instead
|
|
of all target ports.
|
|
|
|
- Example for FC ports:
|
|
|
|
.. code-block:: ini
|
|
|
|
io_port_list = a-1,B-3
|
|
|
|
``a`` or ``B`` is *Storage Processor*, number ``1`` and ``3`` are
|
|
*Port ID*.
|
|
|
|
- Example for iSCSI ports:
|
|
|
|
.. code-block:: ini
|
|
|
|
io_port_list = a-1-0,B-3-0
|
|
|
|
``a`` or ``B`` is *Storage Processor*, the first numbers ``1`` and ``3`` are
|
|
*Port ID* and the second number ``0`` is *Virtual Port ID*
|
|
|
|
.. note::
|
|
|
|
- Rather than de-registered, the registered ports will be simply
|
|
bypassed whatever they are in ``io_port_list`` or not.
|
|
|
|
- The driver will raise an exception if ports in ``io_port_list``
|
|
do not exist in VNX during startup.
|
|
|
|
Force delete volumes in storage group
|
|
-------------------------------------
|
|
|
|
Some ``available`` volumes may remain in storage group on the VNX array due to
|
|
some OpenStack timeout issue. But the VNX array do not allow the user to delete
|
|
the volumes which are in storage group. Option
|
|
``force_delete_lun_in_storagegroup`` is introduced to allow the user to delete
|
|
the ``available`` volumes in this tricky situation.
|
|
|
|
When ``force_delete_lun_in_storagegroup`` is set to ``True`` in the back-end
|
|
section, the driver will move the volumes out of the storage groups and then
|
|
delete them if the user tries to delete the volumes that remain in the storage
|
|
group on the VNX array.
|
|
|
|
The default value of ``force_delete_lun_in_storagegroup`` is ``False``.
|
|
|
|
Over subscription in thin provisioning
|
|
--------------------------------------
|
|
|
|
Over subscription allows that the sum of all volume's capacity (provisioned
|
|
capacity) to be larger than the pool's total capacity.
|
|
|
|
``max_over_subscription_ratio`` in the back-end section is the ratio of
|
|
provisioned capacity over total capacity.
|
|
|
|
The default value of ``max_over_subscription_ratio`` is 20.0, which means the
|
|
provisioned capacity can not exceed the total capacity. If the value of this
|
|
ratio is set larger than 1.0, the provisioned capacity can exceed the total
|
|
capacity.
|
|
|
|
Storage group automatic deletion
|
|
--------------------------------
|
|
|
|
For volume attaching, the driver has a storage group on VNX for each compute
|
|
node hosting the vm instances which are going to consume VNX Block Storage
|
|
(using compute node's host name as storage group's name). All the volumes
|
|
attached to the VM instances in a Compute node will be put into the storage
|
|
group. If ``destroy_empty_storage_group`` is set to ``True``, the driver will
|
|
remove the empty storage group after its last volume is detached. For data
|
|
safety, it does not suggest to set ``destroy_empty_storage_group=True`` unless
|
|
the VNX is exclusively managed by one Block Storage node because consistent
|
|
``lock_path`` is required for operation synchronization for this behavior.
|
|
|
|
Initiator auto deregistration
|
|
-----------------------------
|
|
|
|
Enabling storage group automatic deletion is the precondition of this function.
|
|
If ``initiator_auto_deregistration`` is set to ``True`` is set, the driver will
|
|
deregister all the initiators of the host after its storage group is deleted.
|
|
|
|
FC SAN auto zoning
|
|
------------------
|
|
|
|
The EMC VNX FC driver supports FC SAN auto zoning when ``ZoneManager`` is
|
|
configured. Set ``zoning_mode`` to ``fabric`` in the ``[DEFAULT]`` section to
|
|
enable this feature. For ZoneManager configuration, refer to Block
|
|
Storage official guide.
|
|
|
|
Volume number threshold
|
|
-----------------------
|
|
|
|
In VNX, there is a limitation on the number of pool volumes that can be created
|
|
in the system. When the limitation is reached, no more pool volumes can be
|
|
created even if there is remaining capacity in the storage pool. In other
|
|
words, if the scheduler dispatches a volume creation request to a back end that
|
|
has free capacity but reaches the volume limitation, the creation fails.
|
|
|
|
The default value of ``check_max_pool_luns_threshold`` is ``False``. When
|
|
``check_max_pool_luns_threshold=True``, the pool-based back end will check the
|
|
limit and will report 0 free capacity to the scheduler if the limit is reached.
|
|
So the scheduler will be able to skip this kind of pool-based back end that
|
|
runs out of the pool volume number.
|
|
|
|
iSCSI initiators
|
|
----------------
|
|
|
|
``iscsi_initiators`` is a dictionary of IP addresses of the iSCSI
|
|
initiator ports on OpenStack Compute and Block Storage nodes which want to
|
|
connect to VNX via iSCSI. If this option is configured, the driver will
|
|
leverage this information to find an accessible iSCSI target portal for the
|
|
initiator when attaching volume. Otherwise, the iSCSI target portal will be
|
|
chosen in a relative random way.
|
|
|
|
.. note::
|
|
|
|
This option is only valid for iSCSI driver.
|
|
|
|
Here is an example. VNX will connect ``host1`` with ``10.0.0.1`` and
|
|
``10.0.0.2``. And it will connect ``host2`` with ``10.0.0.3``.
|
|
|
|
The key name (``host1`` in the example) should be the output of
|
|
:command:`hostname` command.
|
|
|
|
.. code-block:: ini
|
|
|
|
iscsi_initiators = {"host1":["10.0.0.1", "10.0.0.2"],"host2":["10.0.0.3"]}
|
|
|
|
Default timeout
|
|
---------------
|
|
|
|
Specify the timeout in minutes for operations like LUN migration, LUN creation,
|
|
etc. For example, LUN migration is a typical long running operation, which
|
|
depends on the LUN size and the load of the array. An upper bound in the
|
|
specific deployment can be set to avoid unnecessary long wait.
|
|
|
|
The default value for this option is ``infinite``.
|
|
|
|
.. code-block:: ini
|
|
|
|
default_timeout = 10
|
|
|
|
Max LUNs per storage group
|
|
--------------------------
|
|
|
|
The ``max_luns_per_storage_group`` specify the maximum number of LUNs in a
|
|
storage group. Default value is 255. It is also the maximum value supported by
|
|
VNX.
|
|
|
|
Ignore pool full threshold
|
|
--------------------------
|
|
|
|
If ``ignore_pool_full_threshold`` is set to ``True``, driver will force LUN
|
|
creation even if the full threshold of pool is reached. Default to ``False``.
|
|
|
|
Extra spec options
|
|
~~~~~~~~~~~~~~~~~~
|
|
|
|
Extra specs are used in volume types created in Block Storage as the preferred
|
|
property of the volume.
|
|
|
|
The Block Storage scheduler will use extra specs to find the suitable back end
|
|
for the volume and the Block Storage driver will create the volume based on the
|
|
properties specified by the extra spec.
|
|
|
|
Use the following command to create a volume type:
|
|
|
|
.. code-block:: console
|
|
|
|
$ cinder type-create "demoVolumeType"
|
|
|
|
Use the following command to update the extra spec of a volume type:
|
|
|
|
.. code-block:: console
|
|
|
|
$ cinder type-key "demoVolumeType" set provisioning:type=thin
|
|
|
|
The following sections describe the VNX extra keys.
|
|
|
|
Provisioning type
|
|
-----------------
|
|
|
|
- Key: ``provisioning:type``
|
|
|
|
- Possible Values:
|
|
|
|
- ``thick``
|
|
|
|
Volume is fully provisioned.
|
|
|
|
Run the following commands to create a ``thick`` volume type:
|
|
|
|
.. code-block:: console
|
|
|
|
$ cinder type-create "ThickVolumeType"
|
|
$ cinder type-key "ThickVolumeType" set provisioning:type=thick thick_provisioning_support='<is> True'
|
|
|
|
- ``thin``
|
|
|
|
Volume is virtually provisioned.
|
|
|
|
Run the following commands to create a ``thin`` volume type:
|
|
|
|
.. code-block:: console
|
|
|
|
$ cinder type-create "ThinVolumeType"
|
|
$ cinder type-key "ThinVolumeType" set provisioning:type=thin thin_provisioning_support='<is> True'
|
|
|
|
- ``deduplicated``
|
|
|
|
Volume is ``thin`` and deduplication is enabled. The administrator shall
|
|
go to VNX to configure the system level deduplication settings. To
|
|
create a deduplicated volume, the VNX Deduplication license must be
|
|
activated on VNX, and specify ``deduplication_support=True`` to let Block
|
|
Storage scheduler find the proper volume back end.
|
|
|
|
Run the following commands to create a ``deduplicated`` volume type:
|
|
|
|
.. code-block:: console
|
|
|
|
$ cinder type-create "DeduplicatedVolumeType"
|
|
$ cinder type-key "DeduplicatedVolumeType" set provisioning:type=deduplicated deduplication_support='<is> True'
|
|
|
|
- ``compressed``
|
|
|
|
Volume is ``thin`` and compression is enabled. The administrator shall go
|
|
to the VNX to configure the system level compression settings. To create
|
|
a compressed volume, the VNX Compression license must be activated on
|
|
VNX, and use ``compression_support=True`` to let Block Storage scheduler
|
|
find a volume back end. VNX does not support creating snapshots on a
|
|
compressed volume.
|
|
|
|
Run the following commands to create a ``compressed`` volume type:
|
|
|
|
.. code-block:: console
|
|
|
|
$ cinder type-create "CompressedVolumeType"
|
|
$ cinder type-key "CompressedVolumeType" set provisioning:type=compressed compression_support='<is> True'
|
|
|
|
- Default: ``thick``
|
|
|
|
.. note::
|
|
|
|
``provisioning:type`` replaces the old spec key
|
|
``storagetype:provisioning``. The latter one will be obsoleted in the next
|
|
release. If both ``provisioning:type`` and ``storagetype:provisioning``
|
|
are set in the volume type, the value of ``provisioning:type`` will be
|
|
used.
|
|
|
|
Storage tiering support
|
|
-----------------------
|
|
|
|
- Key: ``storagetype:tiering``
|
|
|
|
- Possible values:
|
|
|
|
- ``StartHighThenAuto``
|
|
|
|
- ``Auto``
|
|
|
|
- ``HighestAvailable``
|
|
|
|
- ``LowestAvailable``
|
|
|
|
- ``NoMovement``
|
|
|
|
- Default: ``StartHighThenAuto``
|
|
|
|
VNX supports fully automated storage tiering which requires the FAST license
|
|
activated on the VNX. The OpenStack administrator can use the extra spec key
|
|
``storagetype:tiering`` to set the tiering policy of a volume and use the key
|
|
``fast_support='<is> True'`` to let Block Storage scheduler find a volume back
|
|
end which manages a VNX with FAST license activated. Here are the five
|
|
supported values for the extra spec key ``storagetype:tiering``:
|
|
|
|
Run the following commands to create a volume type with tiering policy:
|
|
|
|
.. code-block:: console
|
|
|
|
$ cinder type-create "ThinVolumeOnLowestAvaibleTier"
|
|
$ cinder type-key "CompressedVolumeOnLowestAvaibleTier" set provisioning:type=thin storagetype:tiering=Auto fast_support='<is> True'
|
|
|
|
.. note::
|
|
|
|
The tiering policy cannot be applied to a deduplicated volume. Tiering
|
|
policy of the deduplicated LUN align with the settings of the pool.
|
|
|
|
FAST cache support
|
|
------------------
|
|
|
|
- Key: ``fast_cache_enabled``
|
|
|
|
- Possible values:
|
|
|
|
- ``True``
|
|
|
|
- ``False``
|
|
|
|
- Default: ``False``
|
|
|
|
VNX has FAST Cache feature which requires the FAST Cache license activated on
|
|
the VNX. Volume will be created on the backend with FAST cache enabled when
|
|
``True`` is specified.
|
|
|
|
Snap-copy
|
|
---------
|
|
|
|
- Key: ``copytype:snap``
|
|
|
|
- Possible values:
|
|
|
|
- ``True``
|
|
|
|
- ``False``
|
|
|
|
- Default: ``False``
|
|
|
|
The VNX driver supports snap-copy, which extremely accelerates the process for
|
|
creating a copied volume.
|
|
|
|
By default, the driver will do a full data copy while creating a volume from a
|
|
snapshot or cloning a volume, which is time-consuming especially for large
|
|
volumes. When the snap-copy is used, the driver will simply create a snapshot
|
|
and mount it as a volume for the two types of operations which will be instant
|
|
even for large volumes.
|
|
|
|
To enable this functionality, the source volume should have
|
|
``copytype:snap=True`` in the extra specs of its volume type. Then the new
|
|
volume cloned from the source or copied from the snapshot for the source, will
|
|
be in fact a snap-copy instead of a full copy. If a full copy is needed,
|
|
retype/migration can be used to convert the snap-copy volume to a full-copy
|
|
volume which may be time-consuming.
|
|
|
|
.. code-block:: console
|
|
|
|
$ cinder type-create "SnapCopy"
|
|
$ cinder type-key "SnapCopy" set copytype:snap=True
|
|
|
|
User can determine whether the volume is a snap-copy volume or not by
|
|
showing its metadata. If the ``lun_type`` in metadata is ``smp``, the
|
|
volume is a snap-copy volume. Otherwise, it is a full-copy volume.
|
|
|
|
.. code-block:: console
|
|
|
|
$ cinder metadata-show <volume>
|
|
|
|
**Constraints**
|
|
|
|
- ``copytype:snap=True`` is not allowed in the volume type of a
|
|
consistency group.
|
|
|
|
- Clone and snapshot creation are not allowed on a copied volume
|
|
created through the snap-copy before it is converted to a full copy.
|
|
|
|
- The number of snap-copy volume created from a source volume is
|
|
limited to 255 at one point in time.
|
|
|
|
- The source volume which has snap-copy volume can not be deleted.
|
|
|
|
Pool name
|
|
---------
|
|
|
|
- Key: ``pool_name``
|
|
|
|
- Possible values: name of the storage pool managed by cinder
|
|
|
|
- Default: None
|
|
|
|
If the user wants to create a volume on a certain storage pool in a back end
|
|
that manages multiple pools, a volume type with a extra spec specified storage
|
|
pool should be created first, then the user can use this volume type to create
|
|
the volume.
|
|
|
|
Run the following commands to create the volume type:
|
|
|
|
.. code-block:: console
|
|
|
|
$ cinder type-create "HighPerf"
|
|
$ cinder type-key "HighPerf" set pool_name=Pool_02_SASFLASH volume_backend_name=vnx_41
|
|
|
|
|
|
Advanced features
|
|
~~~~~~~~~~~~~~~~~
|
|
|
|
Read-only volumes
|
|
-----------------
|
|
|
|
OpenStack supports read-only volumes. The following command can be used
|
|
to set a volume as read-only.
|
|
|
|
.. code-block:: console
|
|
|
|
$ cinder readonly-mode-update <volume> True
|
|
|
|
After a volume is marked as read-only, the driver will forward the
|
|
information when a hypervisor is attaching the volume and the hypervisor
|
|
will make sure the volume is read-only.
|
|
|
|
Efficient non-disruptive volume backup
|
|
--------------------------------------
|
|
|
|
The default implementation in Block Storage for non-disruptive volume backup is
|
|
not efficient since a cloned volume will be created during backup.
|
|
|
|
The approach of efficient backup is to create a snapshot for the volume and
|
|
connect this snapshot (a mount point in VNX) to the Block Storage host for
|
|
volume backup. This eliminates migration time involved in volume clone.
|
|
|
|
**Constraints**
|
|
|
|
- Backup creation for a snap-copy volume is not allowed if the volume
|
|
status is ``in-use`` since snapshot cannot be taken from this volume.
|
|
|
|
Best practice
|
|
~~~~~~~~~~~~~
|
|
|
|
.. _multipath-setup:
|
|
|
|
Multipath setup
|
|
---------------
|
|
|
|
Enabling multipath volume access is recommended for robust data access.
|
|
The major configuration includes:
|
|
|
|
#. Install ``multipath-tools``, ``sysfsutils`` and ``sg3-utils`` on the
|
|
nodes hosting Nova-Compute and Cinder-Volume services. Check
|
|
the operating system manual for the system distribution for specific
|
|
installation steps. For Red Hat based distributions, they should be
|
|
``device-mapper-multipath``, ``sysfsutils`` and ``sg3_utils``.
|
|
|
|
#. Specify ``use_multipath_for_image_xfer=true`` in the ``cinder.conf`` file
|
|
for each FC/iSCSI back end.
|
|
|
|
#. Specify ``iscsi_use_multipath=True`` in ``libvirt`` section of the
|
|
``nova.conf`` file. This option is valid for both iSCSI and FC driver.
|
|
|
|
For multipath-tools, here is an EMC recommended sample of
|
|
``/etc/multipath.conf`` file.
|
|
|
|
``user_friendly_names`` is not specified in the configuration and thus
|
|
it will take the default value ``no``. It is not recommended to set it
|
|
to ``yes`` because it may fail operations such as VM live migration.
|
|
|
|
.. code-block:: none
|
|
|
|
blacklist {
|
|
# Skip the files under /dev that are definitely not FC/iSCSI devices
|
|
# Different system may need different customization
|
|
devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*"
|
|
devnode "^hd[a-z][0-9]*"
|
|
devnode "^cciss!c[0-9]d[0-9]*[p[0-9]*]"
|
|
|
|
# Skip LUNZ device from VNX
|
|
device {
|
|
vendor "DGC"
|
|
product "LUNZ"
|
|
}
|
|
}
|
|
|
|
defaults {
|
|
user_friendly_names no
|
|
flush_on_last_del yes
|
|
}
|
|
|
|
devices {
|
|
# Device attributed for EMC CLARiiON and VNX series ALUA
|
|
device {
|
|
vendor "DGC"
|
|
product ".*"
|
|
product_blacklist "LUNZ"
|
|
path_grouping_policy group_by_prio
|
|
path_selector "round-robin 0"
|
|
path_checker emc_clariion
|
|
features "1 queue_if_no_path"
|
|
hardware_handler "1 alua"
|
|
prio alua
|
|
failback immediate
|
|
}
|
|
}
|
|
|
|
.. note::
|
|
|
|
When multipath is used in OpenStack, multipath faulty devices may
|
|
come out in Nova-Compute nodes due to different issues (`Bug
|
|
1336683 <https://bugs.launchpad.net/nova/+bug/1336683>`__ is a
|
|
typical example).
|
|
|
|
A solution to completely avoid faulty devices has not been found yet.
|
|
``faulty_device_cleanup.py`` mitigates this issue when VNX iSCSI storage is
|
|
used. Cloud administrators can deploy the script in all Nova-Compute nodes and
|
|
use a CRON job to run the script on each Nova-Compute node periodically so that
|
|
faulty devices will not stay too long. Refer to: `VNX faulty device
|
|
cleanup <https://github.com/emc-openstack/vnx-faulty-device-cleanup>`__ for
|
|
detailed usage and the script.
|
|
|
|
Restrictions and limitations
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
iSCSI port cache
|
|
----------------
|
|
|
|
EMC VNX iSCSI driver caches the iSCSI ports information, so that the user
|
|
should restart the ``cinder-volume`` service or wait for seconds (which is
|
|
configured by ``periodic_interval`` in the ``cinder.conf`` file) before any
|
|
volume attachment operation after changing the iSCSI port configurations.
|
|
Otherwise the attachment may fail because the old iSCSI port configurations
|
|
were used.
|
|
|
|
No extending for volume with snapshots
|
|
--------------------------------------
|
|
|
|
VNX does not support extending the thick volume which has a snapshot. If the
|
|
user tries to extend a volume which has a snapshot, the status of the volume
|
|
would change to ``error_extending``.
|
|
|
|
Limitations for deploying cinder on computer node
|
|
-------------------------------------------------
|
|
|
|
It is not recommended to deploy the driver on a compute node if ``cinder
|
|
upload-to-image --force True`` is used against an in-use volume. Otherwise,
|
|
``cinder upload-to-image --force True`` will terminate the data access of the
|
|
vm instance to the volume.
|
|
|
|
Storage group with host names in VNX
|
|
------------------------------------
|
|
|
|
When the driver notices that there is no existing storage group that has the
|
|
host name as the storage group name, it will create the storage group and also
|
|
add the compute node's or Block Storage node's registered initiators into the
|
|
storage group.
|
|
|
|
If the driver notices that the storage group already exists, it will assume
|
|
that the registered initiators have also been put into it and skip the
|
|
operations above for better performance.
|
|
|
|
It is recommended that the storage administrator does not create the storage
|
|
group manually and instead relies on the driver for the preparation. If the
|
|
storage administrator needs to create the storage group manually for some
|
|
special requirements, the correct registered initiators should be put into the
|
|
storage group as well (otherwise the following volume attaching operations will
|
|
fail).
|
|
|
|
EMC storage-assisted volume migration
|
|
-------------------------------------
|
|
|
|
EMC VNX driver supports storage-assisted volume migration, when the user starts
|
|
migrating with ``cinder migrate --force-host-copy False <volume_id> <host>`` or
|
|
``cinder migrate <volume_id> <host>``, cinder will try to leverage the VNX's
|
|
native volume migration functionality.
|
|
|
|
In following scenarios, VNX storage-assisted volume migration will not be
|
|
triggered:
|
|
|
|
1. Volume migration between back ends with different storage protocol,
|
|
for example, FC and iSCSI.
|
|
|
|
2. Volume is to be migrated across arrays.
|
|
|
|
Appendix
|
|
~~~~~~~~
|
|
|
|
.. _authenticate-by-security-file:
|
|
|
|
Authenticate by security file
|
|
-----------------------------
|
|
|
|
VNX credentials are necessary when the driver connects to the VNX system.
|
|
Credentials in ``global``, ``local`` and ``ldap`` scopes are supported. There
|
|
are two approaches to provide the credentials.
|
|
|
|
The recommended one is using the Navisphere CLI security file to provide the
|
|
credentials which can get rid of providing the plain text credentials in the
|
|
configuration file. Following is the instruction on how to do this.
|
|
|
|
#. Find out the Linux user id of the ``cinder-volume`` processes. Assuming the
|
|
``cinder-volume`` service is running by the account ``cinder``.
|
|
|
|
#. Run ``su`` as root user.
|
|
|
|
#. In ``/etc/passwd`` file, change
|
|
``cinder:x:113:120::/var/lib/cinder:/bin/false``
|
|
to ``cinder:x:113:120::/var/lib/cinder:/bin/bash`` (This temporary change is
|
|
to make step 4 work.)
|
|
|
|
#. Save the credentials on behalf of ``cinder`` user to a security file
|
|
(assuming the array credentials are ``admin/admin`` in ``global`` scope). In
|
|
the command below, the ``-secfilepath`` switch is used to specify the
|
|
location to save the security file.
|
|
|
|
.. code-block:: console
|
|
|
|
# su -l cinder -c '/opt/Navisphere/bin/naviseccli \
|
|
-AddUserSecurity -user admin -password admin -scope 0 -secfilepath <location>'
|
|
|
|
#. Change ``cinder:x:113:120::/var/lib/cinder:/bin/bash`` back to
|
|
``cinder:x:113:120::/var/lib/cinder:/bin/false`` in ``/etc/passwd`` file.
|
|
|
|
#. Remove the credentials options ``san_login``, ``san_password`` and
|
|
``storage_vnx_authentication_type`` from ``cinder.conf`` file. (normally
|
|
it is ``/etc/cinder/cinder.conf`` file). Add option
|
|
``storage_vnx_security_file_dir`` and set its value to the directory path of
|
|
your security file generated in the above step. Omit this option if
|
|
``-secfilepath`` is not used in the above step.
|
|
|
|
#. Restart the ``cinder-volume`` service to validate the change.
|
|
|
|
|
|
.. _register-fc-port-with-vnx:
|
|
|
|
Register FC port with VNX
|
|
-------------------------
|
|
|
|
This configuration is only required when ``initiator_auto_registration=False``.
|
|
|
|
To access VNX storage, the Compute nodes should be registered on VNX first if
|
|
initiator auto registration is not enabled.
|
|
|
|
To perform ``Copy Image to Volume`` and ``Copy Volume to Image`` operations,
|
|
the nodes running the ``cinder-volume`` service (Block Storage nodes) must be
|
|
registered with the VNX as well.
|
|
|
|
The steps mentioned below are for the compute nodes. Follow the same
|
|
steps for the Block Storage nodes also (The steps can be skipped if initiator
|
|
auto registration is enabled).
|
|
|
|
#. Assume ``20:00:00:24:FF:48:BA:C2:21:00:00:24:FF:48:BA:C2`` is the WWN of a
|
|
FC initiator port name of the compute node whose host name and IP are
|
|
``myhost1`` and ``10.10.61.1``. Register
|
|
``20:00:00:24:FF:48:BA:C2:21:00:00:24:FF:48:BA:C2`` in Unisphere:
|
|
|
|
#. Log in to :guilabel:`Unisphere`, go to
|
|
:menuselection:`FNM0000000000 > Hosts > Initiators`.
|
|
|
|
#. Refresh and wait until the initiator
|
|
``20:00:00:24:FF:48:BA:C2:21:00:00:24:FF:48:BA:C2`` with SP Port ``A-1``
|
|
appears.
|
|
|
|
#. Click the :guilabel:`Register` button, select :guilabel:`CLARiiON/VNX`
|
|
and enter the host name (which is the output of the :command:`hostname`
|
|
command) and IP address:
|
|
|
|
- Hostname: ``myhost1``
|
|
|
|
- IP: ``10.10.61.1``
|
|
|
|
- Click :guilabel:`Register`.
|
|
|
|
#. Then host ``10.10.61.1`` will appear under
|
|
:menuselection:`Hosts > Host List` as well.
|
|
|
|
#. Register the ``wwn`` with more ports if needed.
|
|
|
|
.. _register-iscsi-port-with-vnx:
|
|
|
|
Register iSCSI port with VNX
|
|
----------------------------
|
|
|
|
This configuration is only required when ``initiator_auto_registration=False``.
|
|
|
|
To access VNX storage, the compute nodes should be registered on VNX first if
|
|
initiator auto registration is not enabled.
|
|
|
|
To perform ``Copy Image to Volume`` and ``Copy Volume to Image`` operations,
|
|
the nodes running the ``cinder-volume`` service (Block Storage nodes) must be
|
|
registered with the VNX as well.
|
|
|
|
The steps mentioned below are for the compute nodes. Follow the
|
|
same steps for the Block Storage nodes also (The steps can be skipped if
|
|
initiator auto registration is enabled).
|
|
|
|
#. On the compute node with IP address ``10.10.61.1`` and host name ``myhost1``,
|
|
execute the following commands (assuming ``10.10.61.35`` is the iSCSI
|
|
target):
|
|
|
|
#. Start the iSCSI initiator service on the node:
|
|
|
|
.. code-block:: console
|
|
|
|
# /etc/init.d/open-iscsi start
|
|
|
|
#. Discover the iSCSI target portals on VNX:
|
|
|
|
.. code-block:: console
|
|
|
|
# iscsiadm -m discovery -t st -p 10.10.61.35
|
|
|
|
#. Change directory to ``/etc/iscsi`` :
|
|
|
|
.. code-block:: console
|
|
|
|
# cd /etc/iscsi
|
|
|
|
#. Find out the ``iqn`` of the node:
|
|
|
|
.. code-block:: console
|
|
|
|
# more initiatorname.iscsi
|
|
|
|
#. Log in to :guilabel:`VNX` from the compute node using the target
|
|
corresponding to the SPA port:
|
|
|
|
.. code-block:: console
|
|
|
|
# iscsiadm -m node -T iqn.1992-04.com.emc:cx.apm01234567890.a0 -p 10.10.61.35 -l
|
|
|
|
#. Assume ``iqn.1993-08.org.debian:01:1a2b3c4d5f6g`` is the initiator name of
|
|
the compute node. Register ``iqn.1993-08.org.debian:01:1a2b3c4d5f6g`` in
|
|
Unisphere:
|
|
|
|
#. Log in to :guilabel:`Unisphere`, go to
|
|
:menuselection:`FNM0000000000 > Hosts > Initiators`.
|
|
|
|
#. Refresh and wait until the initiator
|
|
``iqn.1993-08.org.debian:01:1a2b3c4d5f6g`` with SP Port ``A-8v0`` appears.
|
|
|
|
#. Click the :guilabel:`Register` button, select :guilabel:`CLARiiON/VNX`
|
|
and enter the host name
|
|
(which is the output of the :command:`hostname` command) and IP address:
|
|
|
|
- Hostname: ``myhost1``
|
|
|
|
- IP: ``10.10.61.1``
|
|
|
|
- Click :guilabel:`Register`.
|
|
|
|
#. Then host ``10.10.61.1`` will appear under
|
|
:menuselection:`Hosts > Host List` as well.
|
|
|
|
#. Log out :guilabel:`iSCSI` on the node:
|
|
|
|
.. code-block:: console
|
|
|
|
# iscsiadm -m node -u
|
|
|
|
#. Log in to :guilabel:`VNX` from the compute node using the target
|
|
corresponding to the SPB port:
|
|
|
|
.. code-block:: console
|
|
|
|
# iscsiadm -m node -T iqn.1992-04.com.emc:cx.apm01234567890.b8 -p 10.10.61.36 -l
|
|
|
|
#. In ``Unisphere``, register the initiator with the SPB port.
|
|
|
|
#. Log out :guilabel:`iSCSI` on the node:
|
|
|
|
.. code-block:: console
|
|
|
|
# iscsiadm -m node -u
|
|
|
|
#. Register the ``iqn`` with more ports if needed.
|