EMC VNX driver
==============
EMC VNX driver consists of EMCCLIISCSIDriver and EMCCLIFCDriver, and supports
both iSCSI and FC protocol. ``EMCCLIISCSIDriver`` (VNX iSCSI driver) and
``EMCCLIFCDriver`` (VNX FC driver) are separately based on the ``ISCSIDriver``
and ``FCDriver`` defined in the Block Storage service.
The VNX iSCSI driver and VNX FC driver perform the volume operations by
executing Navisphere CLI (NaviSecCLI) which is a command-line interface used
for management, diagnostics, and reporting functions for VNX.
System requirements
~~~~~~~~~~~~~~~~~~~
- VNX Operational Environment for Block version 5.32 or higher.
- VNX Snapshot and Thin Provisioning license should be activated for VNX.
- Navisphere CLI v7.32 or higher is installed along with the driver.
Supported operations
~~~~~~~~~~~~~~~~~~~~
- Create, delete, attach, and detach volumes.
- Create, list, and delete volume snapshots.
- Create a volume from a snapshot.
- Copy an image to a volume.
- Clone a volume.
- Extend a volume.
- Migrate a volume.
- Retype a volume.
- Get volume statistics.
- Create and delete consistency groups.
- Create, list, and delete consistency group snapshots.
- Modify consistency groups.
- Efficient non-disruptive volume backup.
Preparation
~~~~~~~~~~~
This section contains instructions to prepare the Block Storage nodes to
use the EMC VNX driver. You install the Navisphere CLI, install the
driver, ensure you have correct zoning configurations, and register the
driver.
Install Navisphere CLI
----------------------
Navisphere CLI needs to be installed on all Block Storage nodes within
an OpenStack deployment. You need to download different versions for
different platforms:
- For Ubuntu x64, DEB is available at `EMC OpenStack
Github <https://github.com/emc-openstack/naviseccli>`__.
- For all other variants of Linux, Navisphere CLI is available at
`Downloads for VNX2
Series <https://support.emc.com/downloads/36656_VNX2-Series>`__ or
`Downloads for VNX1
Series <https://support.emc.com/downloads/12781_VNX1-Series>`__.
- After installation, set the security level of Navisphere CLI to low:
.. code-block:: console
$ /opt/Navisphere/bin/naviseccli security -certificate -setLevel low
Check array software
--------------------
Make sure your have the following software installed for certain features:
+--------------------------------------------+---------------------+
| Feature | Software Required |
+============================================+=====================+
| All | ThinProvisioning |
+--------------------------------------------+---------------------+
| All | VNXSnapshots |
+--------------------------------------------+---------------------+
| FAST cache support | FASTCache |
+--------------------------------------------+---------------------+
| Create volume with type ``compressed`` | Compression |
+--------------------------------------------+---------------------+
| Create volume with type ``deduplicated`` | Deduplication |
+--------------------------------------------+---------------------+
**Required software**
You can check the status of your array software in the :guilabel:`Software`
page of :guilabel:`Storage System Properties`. Here is how it looks like:
.. figure:: ../../figures/emc-enabler.png
Network configuration
---------------------
For the FC Driver, FC zoning is properly configured between the hosts and
the VNX. Check :ref:`register-fc-port-with-vnx` for reference.
For the iSCSI Driver, make sure your VNX iSCSI port is accessible by
your hosts. Check :ref:`register-iscsi-port-with-vnx` for reference.
You can use ``initiator_auto_registration = True`` configuration to avoid
registering the ports manually. Check the detail of the configuration in
:ref:`emc-vnx-conf` for reference.
If you are trying to setup multipath, refer to :ref:`multipath-setup`.
.. _emc-vnx-conf:
Back-end configuration
~~~~~~~~~~~~~~~~~~~~~~
Make the following changes in the ``/etc/cinder/cinder.conf`` file.
Minimum configuration
---------------------
Here is a sample of a minimum back-end configuration. See the following
sections for the detail of each option. Replace ``EMCCLIFCDriver``
with ``EMCCLIISCSIDriver`` if you are using the iSCSI driver.
.. code-block:: ini
[DEFAULT]
enabled_backends = vnx_array1
[vnx_array1]
san_ip = 10.10.72.41
san_login = sysadmin
san_password = sysadmin
naviseccli_path = /opt/Navisphere/bin/naviseccli
volume_driver = cinder.volume.drivers.emc.emc_cli_fc.EMCCLIFCDriver
initiator_auto_registration = True
Multiple back-end configuration
-------------------------------
Here is a sample of a multiple back-end configuration. See the following
sections for the detail of each option. Replace ``EMCCLIFCDriver``
with ``EMCCLIISCSIDriver`` if you are using the iSCSI driver.
.. code-block:: ini
[DEFAULT]
enabled_backends = backendA, backendB
[backendA]
storage_vnx_pool_names = Pool_01_SAS, Pool_02_FLASH
san_ip = 10.10.72.41
storage_vnx_security_file_dir = /etc/secfile/array1
naviseccli_path = /opt/Navisphere/bin/naviseccli
volume_driver = cinder.volume.drivers.emc.emc_cli_fc.EMCCLIFCDriver
initiator_auto_registration = True
[backendB]
storage_vnx_pool_names = Pool_02_SAS
san_ip = 10.10.26.101
san_login = username
san_password = password
naviseccli_path = /opt/Navisphere/bin/naviseccli
volume_driver = cinder.volume.drivers.emc.emc_cli_fc.EMCCLIFCDriver
initiator_auto_registration = True
For more details on multi-backends, see `OpenStack Cloud Administration Guide
<http://docs.openstack.org/admin-guide-cloud/index.html>`__
Required configurations
-----------------------
**IP of the VNX Storage Processors**
Specify the SP A and SP B IP to connect:
.. code-block:: ini
san_ip = <IP of VNX Storage Processor A>
san_secondary_ip = <IP of VNX Storage Processor B>
**VNX login credentials**
There are two ways to specify the credentials.
- Use plain text username and password.
Supply for plain username and password:
.. code-block:: ini
san_login = <VNX account with administrator role>
san_password = <password for VNX account>
storage_vnx_authentication_type = global
Valid values for ``storage_vnx_authentication_type`` are: ``global``
(default), ``local``, and ``ldap``.
- Use Security file.
This approach avoids the plain text password in your cinder
configuration file. Supply a security file as below:
.. code-block:: ini
storage_vnx_security_file_dir = <path to security file>
Check Unisphere CLI user guide or :ref:`authenticate-by-security-file`
for how to create a security file.
**Path to your Unisphere CLI**
Specify the absolute path to your naviseccli:
.. code-block:: ini
naviseccli_path = /opt/Navisphere/bin/naviseccli
**Driver name**
- For the FC Driver, add the following option:
.. code-block:: ini
volume_driver = cinder.volume.drivers.emc.emc_cli_fc.EMCCLIFCDriver
- For iSCSI Driver, add the following option:
.. code-block:: ini
volume_driver = cinder.volume.drivers.emc.emc_cli_iscsi.EMCCLIISCSIDriver
Optional configurations
~~~~~~~~~~~~~~~~~~~~~~~
VNX pool names
--------------
Specify the list of pools to be managed, separated by commas. They should
already exist in VNX.
.. code-block:: ini
storage_vnx_pool_names = pool 1, pool 2
If this value is not specified, all pools of the array will be used.
**Initiator auto registration**
When ``initiator_auto_registration`` is set to ``True``, the driver will
automatically register initiators to all working target ports of the VNX array
during volume attaching (The driver will skip those initiators that have
already been registered) if the option ``io_port_list`` is not specified in
the ``cinder.conf`` file.
If the user wants to register the initiators with some specific ports but not
register with the other ports, this functionality should be disabled.
When a comma-separated list is given to ``io_port_list``, the driver will only
register the initiator to the ports specified in the list and only return
target port(s) which belong to the target ports in the ``io_port_list`` instead
of all target ports.
- Example for FC ports:
.. code-block:: ini
io_port_list = a-1,B-3
``a`` or ``B`` is *Storage Processor*, number ``1`` and ``3`` are
*Port ID*.
- Example for iSCSI ports:
.. code-block:: ini
io_port_list = a-1-0,B-3-0
``a`` or ``B`` is *Storage Processor*, the first numbers ``1`` and ``3`` are
*Port ID* and the second number ``0`` is *Virtual Port ID*
.. note::
- Rather than de-registered, the registered ports will be simply
bypassed whatever they are in ``io_port_list`` or not.
- The driver will raise an exception if ports in ``io_port_list``
do not exist in VNX during startup.
Force delete volumes in storage group
-------------------------------------
Some ``available`` volumes may remain in storage group on the VNX array due to
some OpenStack timeout issue. But the VNX array do not allow the user to delete
the volumes which are in storage group. Option
``force_delete_lun_in_storagegroup`` is introduced to allow the user to delete
the ``available`` volumes in this tricky situation.
When ``force_delete_lun_in_storagegroup`` is set to ``True`` in the back-end
section, the driver will move the volumes out of the storage groups and then
delete them if the user tries to delete the volumes that remain in the storage
group on the VNX array.
The default value of ``force_delete_lun_in_storagegroup`` is ``False``.
Over subscription in thin provisioning
--------------------------------------
Over subscription allows that the sum of all volume's capacity (provisioned
capacity) to be larger than the pool's total capacity.
``max_over_subscription_ratio`` in the back-end section is the ratio of
provisioned capacity over total capacity.
The default value of ``max_over_subscription_ratio`` is 20.0, which means the
provisioned capacity can not exceed the total capacity. If the value of this
ratio is set larger than 1.0, the provisioned capacity can exceed the total
capacity.
Storage group automatic deletion
--------------------------------
For volume attaching, the driver has a storage group on VNX for each compute
node hosting the vm instances which are going to consume VNX Block Storage
(using compute node's host name as storage group's name). All the volumes
attached to the VM instances in a Compute node will be put into the storage
group. If ``destroy_empty_storage_group`` is set to ``True``, the driver will
remove the empty storage group after its last volume is detached. For data
safety, it does not suggest to set ``destroy_empty_storage_group=True`` unless
the VNX is exclusively managed by one Block Storage node because consistent
``lock_path`` is required for operation synchronization for this behavior.
Initiator auto deregistration
-----------------------------
Enabling storage group automatic deletion is the precondition of this function.
If ``initiator_auto_deregistration`` is set to ``True`` is set, the driver will
deregister all the initiators of the host after its storage group is deleted.
FC SAN auto zoning
------------------
The EMC VNX FC driver supports FC SAN auto zoning when ``ZoneManager`` is
configured. Set ``zoning_mode`` to ``fabric`` in the ``[DEFAULT]`` section to
enable this feature. For ZoneManager configuration, refer to Block
Storage official guide.
Volume number threshold
-----------------------
In VNX, there is a limitation on the number of pool volumes that can be created
in the system. When the limitation is reached, no more pool volumes can be
created even if there is remaining capacity in the storage pool. In other
words, if the scheduler dispatches a volume creation request to a back end that
has free capacity but reaches the volume limitation, the creation fails.
The default value of ``check_max_pool_luns_threshold`` is ``False``. When
``check_max_pool_luns_threshold=True``, the pool-based back end will check the
limit and will report 0 free capacity to the scheduler if the limit is reached.
So the scheduler will be able to skip this kind of pool-based back end that
runs out of the pool volume number.
iSCSI initiators
----------------
``iscsi_initiators`` is a dictionary of IP addresses of the iSCSI
initiator ports on OpenStack Compute and Block Storage nodes which want to
connect to VNX via iSCSI. If this option is configured, the driver will
leverage this information to find an accessible iSCSI target portal for the
initiator when attaching volume. Otherwise, the iSCSI target portal will be
chosen in a relative random way.
.. note::
This option is only valid for iSCSI driver.
Here is an example. VNX will connect ``host1`` with ``10.0.0.1`` and
``10.0.0.2``. And it will connect ``host2`` with ``10.0.0.3``.
The key name (``host1`` in the example) should be the output of
:command:`hostname` command.
.. code-block:: ini
iscsi_initiators = {"host1":["10.0.0.1", "10.0.0.2"],"host2":["10.0.0.3"]}
Default timeout
---------------
Specify the timeout in minutes for operations like LUN migration, LUN creation,
etc. For example, LUN migration is a typical long running operation, which
depends on the LUN size and the load of the array. An upper bound in the
specific deployment can be set to avoid unnecessary long wait.
The default value for this option is ``infinite``.
.. code-block:: ini
default_timeout = 10
Max LUNs per storage group
--------------------------
The ``max_luns_per_storage_group`` specify the maximum number of LUNs in a
storage group. Default value is 255. It is also the maximum value supported by
VNX.
Ignore pool full threshold
--------------------------
If ``ignore_pool_full_threshold`` is set to ``True``, driver will force LUN
creation even if the full threshold of pool is reached. Default to ``False``.
Extra spec options
~~~~~~~~~~~~~~~~~~
Extra specs are used in volume types created in Block Storage as the preferred
property of the volume.
The Block Storage scheduler will use extra specs to find the suitable back end
for the volume and the Block Storage driver will create the volume based on the
properties specified by the extra spec.
Use the following command to create a volume type:
.. code-block:: console
$ cinder type-create "demoVolumeType"
Use the following command to update the extra spec of a volume type:
.. code-block:: console
$ cinder type-key "demoVolumeType" set provisioning:type=thin
The following sections describe the VNX extra keys.
Provisioning type
-----------------
- Key: ``provisioning:type``
- Possible Values:
- ``thick``
Volume is fully provisioned.
Run the following commands to create a ``thick`` volume type:
.. code-block:: console
$ cinder type-create "ThickVolumeType"
$ cinder type-key "ThickVolumeType" set provisioning:type=thick thick_provisioning_support='<is> True'
- ``thin``
Volume is virtually provisioned.
Run the following commands to create a ``thin`` volume type:
.. code-block:: console
$ cinder type-create "ThinVolumeType"
$ cinder type-key "ThinVolumeType" set provisioning:type=thin thin_provisioning_support='<is> True'
- ``deduplicated``
Volume is ``thin`` and deduplication is enabled. The administrator shall
go to VNX to configure the system level deduplication settings. To
create a deduplicated volume, the VNX Deduplication license must be
activated on VNX, and specify ``deduplication_support=True`` to let Block
Storage scheduler find the proper volume back end.
Run the following commands to create a ``deduplicated`` volume type:
.. code-block:: console
$ cinder type-create "DeduplicatedVolumeType"
$ cinder type-key "DeduplicatedVolumeType" set provisioning:type=deduplicated deduplication_support='<is> True'
- ``compressed``
Volume is ``thin`` and compression is enabled. The administrator shall go
to the VNX to configure the system level compression settings. To create
a compressed volume, the VNX Compression license must be activated on
VNX, and use ``compression_support=True`` to let Block Storage scheduler
find a volume back end. VNX does not support creating snapshots on a
compressed volume.
Run the following commands to create a ``compressed`` volume type:
.. code-block:: console
$ cinder type-create "CompressedVolumeType"
$ cinder type-key "CompressedVolumeType" set provisioning:type=compressed compression_support='<is> True'
- Default: ``thick``
.. note::
``provisioning:type`` replaces the old spec key
``storagetype:provisioning``. The latter one will be obsoleted in the next
release. If both ``provisioning:type`` and ``storagetype:provisioning``
are set in the volume type, the value of ``provisioning:type`` will be
used.
Storage tiering support
-----------------------
- Key: ``storagetype:tiering``
- Possible values:
- ``StartHighThenAuto``
- ``Auto``
- ``HighestAvailable``
- ``LowestAvailable``
- ``NoMovement``
- Default: ``StartHighThenAuto``
VNX supports fully automated storage tiering which requires the FAST license
activated on the VNX. The OpenStack administrator can use the extra spec key
``storagetype:tiering`` to set the tiering policy of a volume and use the key
``fast_support='<is> True'`` to let Block Storage scheduler find a volume back
end which manages a VNX with FAST license activated. Here are the five
supported values for the extra spec key ``storagetype:tiering``:
Run the following commands to create a volume type with tiering policy:
.. code-block:: console
$ cinder type-create "ThinVolumeOnLowestAvaibleTier"
$ cinder type-key "CompressedVolumeOnLowestAvaibleTier" set provisioning:type=thin storagetype:tiering=Auto fast_support='<is> True'
.. note::
The tiering policy cannot be applied to a deduplicated volume. Tiering
policy of the deduplicated LUN align with the settings of the pool.
FAST cache support
------------------
- Key: ``fast_cache_enabled``
- Possible values:
- ``True``
- ``False``
- Default: ``False``
VNX has FAST Cache feature which requires the FAST Cache license activated on
the VNX. Volume will be created on the backend with FAST cache enabled when
``True`` is specified.
Snap-copy
---------
- Key: ``copytype:snap``
- Possible values:
- ``True``
- ``False``
- Default: ``False``
The VNX driver supports snap-copy, which extremely accelerates the process for
creating a copied volume.
By default, the driver will do a full data copy while creating a volume from a
snapshot or cloning a volume, which is time-consuming especially for large
volumes. When the snap-copy is used, the driver will simply create a snapshot
and mount it as a volume for the two types of operations which will be instant
even for large volumes.
To enable this functionality, the source volume should have
``copytype:snap=True`` in the extra specs of its volume type. Then the new
volume cloned from the source or copied from the snapshot for the source, will
be in fact a snap-copy instead of a full copy. If a full copy is needed,
retype/migration can be used to convert the snap-copy volume to a full-copy
volume which may be time-consuming.
.. code-block:: console
$ cinder type-create "SnapCopy"
$ cinder type-key "SnapCopy" set copytype:snap=True
User can determine whether the volume is a snap-copy volume or not by
showing its metadata. If the ``lun_type`` in metadata is ``smp``, the
volume is a snap-copy volume. Otherwise, it is a full-copy volume.
.. code-block:: console
$ cinder metadata-show <volume>
**Constraints**
- ``copytype:snap=True`` is not allowed in the volume type of a
consistency group.
- Clone and snapshot creation are not allowed on a copied volume
created through the snap-copy before it is converted to a full copy.
- The number of snap-copy volume created from a source volume is
limited to 255 at one point in time.
- The source volume which has snap-copy volume can not be deleted.
Pool name
---------
- Key: ``pool_name``
- Possible values: name of the storage pool managed by cinder
- Default: None
If the user wants to create a volume on a certain storage pool in a back end
that manages multiple pools, a volume type with a extra spec specified storage
pool should be created first, then the user can use this volume type to create
the volume.
Run the following commands to create the volume type:
.. code-block:: console
$ cinder type-create "HighPerf"
$ cinder type-key "HighPerf" set pool_name=Pool_02_SASFLASH volume_backend_name=vnx_41
Advanced features
~~~~~~~~~~~~~~~~~
Read-only volumes
-----------------
OpenStack supports read-only volumes. The following command can be used
to set a volume as read-only.
.. code-block:: console
$ cinder readonly-mode-update <volume> True
After a volume is marked as read-only, the driver will forward the
information when a hypervisor is attaching the volume and the hypervisor
will make sure the volume is read-only.
Efficient non-disruptive volume backup
--------------------------------------
The default implementation in Block Storage for non-disruptive volume backup is
not efficient since a cloned volume will be created during backup.
The approach of efficient backup is to create a snapshot for the volume and
connect this snapshot (a mount point in VNX) to the Block Storage host for
volume backup. This eliminates migration time involved in volume clone.
**Constraints**
- Backup creation for a snap-copy volume is not allowed if the volume
status is ``in-use`` since snapshot cannot be taken from this volume.
Best practice
~~~~~~~~~~~~~
.. _multipath-setup:
Multipath setup
---------------
Enabling multipath volume access is recommended for robust data access.
The major configuration includes:
#. Install ``multipath-tools``, ``sysfsutils`` and ``sg3-utils`` on the
nodes hosting Nova-Compute and Cinder-Volume services. Check
the operating system manual for the system distribution for specific
installation steps. For Red Hat based distributions, they should be
``device-mapper-multipath``, ``sysfsutils`` and ``sg3_utils``.
#. Specify ``use_multipath_for_image_xfer=true`` in the ``cinder.conf`` file
for each FC/iSCSI back end.
#. Specify ``iscsi_use_multipath=True`` in ``libvirt`` section of the
``nova.conf`` file. This option is valid for both iSCSI and FC driver.
For multipath-tools, here is an EMC recommended sample of
``/etc/multipath.conf`` file.
``user_friendly_names`` is not specified in the configuration and thus
it will take the default value ``no``. It is not recommended to set it
to ``yes`` because it may fail operations such as VM live migration.
.. code-block:: none
blacklist {
# Skip the files under /dev that are definitely not FC/iSCSI devices
# Different system may need different customization
devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*"
devnode "^hd[a-z][0-9]*"
devnode "^cciss!c[0-9]d[0-9]*[p[0-9]*]"
# Skip LUNZ device from VNX
device {
vendor "DGC"
product "LUNZ"
}
}
defaults {
user_friendly_names no
flush_on_last_del yes
}
devices {
# Device attributed for EMC CLARiiON and VNX series ALUA
device {
vendor "DGC"
product ".*"
product_blacklist "LUNZ"
path_grouping_policy group_by_prio
path_selector "round-robin 0"
path_checker emc_clariion
features "1 queue_if_no_path"
hardware_handler "1 alua"
prio alua
failback immediate
}
}
.. note::
When multipath is used in OpenStack, multipath faulty devices may
come out in Nova-Compute nodes due to different issues (`Bug
1336683 <https://bugs.launchpad.net/nova/+bug/1336683>`__ is a
typical example).
A solution to completely avoid faulty devices has not been found yet.
``faulty_device_cleanup.py`` mitigates this issue when VNX iSCSI storage is
used. Cloud administrators can deploy the script in all Nova-Compute nodes and
use a CRON job to run the script on each Nova-Compute node periodically so that
faulty devices will not stay too long. Refer to: `VNX faulty device
cleanup <https://github.com/emc-openstack/vnx-faulty-device-cleanup>`__ for
detailed usage and the script.
Restrictions and limitations
~~~~~~~~~~~~~~~~~~~~~~~~~~~~
iSCSI port cache
----------------
EMC VNX iSCSI driver caches the iSCSI ports information, so that the user
should restart the ``cinder-volume`` service or wait for seconds (which is
configured by ``periodic_interval`` in the ``cinder.conf`` file) before any
volume attachment operation after changing the iSCSI port configurations.
Otherwise the attachment may fail because the old iSCSI port configurations
were used.
No extending for volume with snapshots
--------------------------------------
VNX does not support extending the thick volume which has a snapshot. If the
user tries to extend a volume which has a snapshot, the status of the volume
would change to ``error_extending``.
Limitations for deploying cinder on computer node
-------------------------------------------------
It is not recommended to deploy the driver on a compute node if ``cinder
upload-to-image --force True`` is used against an in-use volume. Otherwise,
``cinder upload-to-image --force True`` will terminate the data access of the
vm instance to the volume.
Storage group with host names in VNX
------------------------------------
When the driver notices that there is no existing storage group that has the
host name as the storage group name, it will create the storage group and also
add the compute node's or Block Storage node's registered initiators into the
storage group.
If the driver notices that the storage group already exists, it will assume
that the registered initiators have also been put into it and skip the
operations above for better performance.
It is recommended that the storage administrator does not create the storage
group manually and instead relies on the driver for the preparation. If the
storage administrator needs to create the storage group manually for some
special requirements, the correct registered initiators should be put into the
storage group as well (otherwise the following volume attaching operations will
fail).
EMC storage-assisted volume migration
-------------------------------------
EMC VNX driver supports storage-assisted volume migration, when the user starts
migrating with ``cinder migrate --force-host-copy False <volume_id> <host>`` or
``cinder migrate <volume_id> <host>``, cinder will try to leverage the VNX's
native volume migration functionality.
In following scenarios, VNX storage-assisted volume migration will not be
triggered:
1. Volume migration between back ends with different storage protocol,
for example, FC and iSCSI.
2. Volume is to be migrated across arrays.
Appendix
~~~~~~~~
.. _authenticate-by-security-file:
Authenticate by security file
-----------------------------
VNX credentials are necessary when the driver connects to the VNX system.
Credentials in ``global``, ``local`` and ``ldap`` scopes are supported. There
are two approaches to provide the credentials.
The recommended one is using the Navisphere CLI security file to provide the
credentials which can get rid of providing the plain text credentials in the
configuration file. Following is the instruction on how to do this.
#. Find out the Linux user id of the ``cinder-volume`` processes. Assuming the
``cinder-volume`` service is running by the account ``cinder``.
#. Run ``su`` as root user.
#. In ``/etc/passwd`` file, change
``cinder:x:113:120::/var/lib/cinder:/bin/false``
to ``cinder:x:113:120::/var/lib/cinder:/bin/bash`` (This temporary change is
to make step 4 work.)
#. Save the credentials on behalf of ``cinder`` user to a security file
(assuming the array credentials are ``admin/admin`` in ``global`` scope). In
the command below, the ``-secfilepath`` switch is used to specify the
location to save the security file.
.. code-block:: console
# su -l cinder -c '/opt/Navisphere/bin/naviseccli \
-AddUserSecurity -user admin -password admin -scope 0 -secfilepath <location>'
#. Change ``cinder:x:113:120::/var/lib/cinder:/bin/bash`` back to
``cinder:x:113:120::/var/lib/cinder:/bin/false`` in ``/etc/passwd`` file.
#. Remove the credentials options ``san_login``, ``san_password`` and
``storage_vnx_authentication_type`` from ``cinder.conf`` file. (normally
it is ``/etc/cinder/cinder.conf`` file). Add option
``storage_vnx_security_file_dir`` and set its value to the directory path of
your security file generated in the above step. Omit this option if
``-secfilepath`` is not used in the above step.
#. Restart the ``cinder-volume`` service to validate the change.
.. _register-fc-port-with-vnx:
Register FC port with VNX
-------------------------
This configuration is only required when ``initiator_auto_registration=False``.
To access VNX storage, the Compute nodes should be registered on VNX first if
initiator auto registration is not enabled.
To perform ``Copy Image to Volume`` and ``Copy Volume to Image`` operations,
the nodes running the ``cinder-volume`` service (Block Storage nodes) must be
registered with the VNX as well.
The steps mentioned below are for the compute nodes. Follow the same
steps for the Block Storage nodes also (The steps can be skipped if initiator
auto registration is enabled).
#. Assume ``20:00:00:24:FF:48:BA:C2:21:00:00:24:FF:48:BA:C2`` is the WWN of a
FC initiator port name of the compute node whose host name and IP are
``myhost1`` and ``10.10.61.1``. Register
``20:00:00:24:FF:48:BA:C2:21:00:00:24:FF:48:BA:C2`` in Unisphere:
#. Log in to :guilabel:`Unisphere`, go to
:menuselection:`FNM0000000000 > Hosts > Initiators`.
#. Refresh and wait until the initiator
``20:00:00:24:FF:48:BA:C2:21:00:00:24:FF:48:BA:C2`` with SP Port ``A-1``
appears.
#. Click the :guilabel:`Register` button, select :guilabel:`CLARiiON/VNX`
and enter the host name (which is the output of the :command:`hostname`
command) and IP address:
- Hostname: ``myhost1``
- IP: ``10.10.61.1``
- Click :guilabel:`Register`.
#. Then host ``10.10.61.1`` will appear under
:menuselection:`Hosts > Host List` as well.
#. Register the ``wwn`` with more ports if needed.
.. _register-iscsi-port-with-vnx:
Register iSCSI port with VNX
----------------------------
This configuration is only required when ``initiator_auto_registration=False``.
To access VNX storage, the compute nodes should be registered on VNX first if
initiator auto registration is not enabled.
To perform ``Copy Image to Volume`` and ``Copy Volume to Image`` operations,
the nodes running the ``cinder-volume`` service (Block Storage nodes) must be
registered with the VNX as well.
The steps mentioned below are for the compute nodes. Follow the
same steps for the Block Storage nodes also (The steps can be skipped if
initiator auto registration is enabled).
#. On the compute node with IP address ``10.10.61.1`` and host name ``myhost1``,
execute the following commands (assuming ``10.10.61.35`` is the iSCSI
target):
#. Start the iSCSI initiator service on the node:
.. code-block:: console
# /etc/init.d/open-iscsi start
#. Discover the iSCSI target portals on VNX:
.. code-block:: console
# iscsiadm -m discovery -t st -p 10.10.61.35
#. Change directory to ``/etc/iscsi`` :
.. code-block:: console
# cd /etc/iscsi
#. Find out the ``iqn`` of the node:
.. code-block:: console
# more initiatorname.iscsi
#. Log in to :guilabel:`VNX` from the compute node using the target
corresponding to the SPA port:
.. code-block:: console
# iscsiadm -m node -T iqn.1992-04.com.emc:cx.apm01234567890.a0 -p 10.10.61.35 -l
#. Assume ``iqn.1993-08.org.debian:01:1a2b3c4d5f6g`` is the initiator name of
the compute node. Register ``iqn.1993-08.org.debian:01:1a2b3c4d5f6g`` in
Unisphere:
#. Log in to :guilabel:`Unisphere`, go to
:menuselection:`FNM0000000000 > Hosts > Initiators`.
#. Refresh and wait until the initiator
``iqn.1993-08.org.debian:01:1a2b3c4d5f6g`` with SP Port ``A-8v0`` appears.
#. Click the :guilabel:`Register` button, select :guilabel:`CLARiiON/VNX`
and enter the host name
(which is the output of the :command:`hostname` command) and IP address:
- Hostname: ``myhost1``
- IP: ``10.10.61.1``
- Click :guilabel:`Register`.
#. Then host ``10.10.61.1`` will appear under
:menuselection:`Hosts > Host List` as well.
#. Log out :guilabel:`iSCSI` on the node:
.. code-block:: console
# iscsiadm -m node -u
#. Log in to :guilabel:`VNX` from the compute node using the target
corresponding to the SPB port:
.. code-block:: console
# iscsiadm -m node -T iqn.1992-04.com.emc:cx.apm01234567890.b8 -p 10.10.61.36 -l
#. In ``Unisphere``, register the initiator with the SPB port.
#. Log out :guilabel:`iSCSI` on the node:
.. code-block:: console
# iscsiadm -m node -u
#. Register the ``iqn`` with more ports if needed.