Description of IBM FlashSystem volume driver configuration options
Configuration option = Default value Description
[DEFAULT]
flashsystem_connection_protocol = FC (String) Connection protocol should be FC. (Default is FC.)
flashsystem_iscsi_portid = 0 (Integer) Default iSCSI Port ID of FlashSystem. (Default port is 0.)
flashsystem_multihostmap_enabled = True (Boolean) Allows vdisk to multi host mapping. (Default is True)
flashsystem_multipath_enabled = False (Boolean) DEPRECATED: This option no longer has any affect. It is deprecated and will be removed in the next release.