- publishers are currently shown on collection and retrieval pages but is really related to pipeline. move it all to pipeline page and remove from other places. - pipeline doesn't do collection so drop the polling stuff because that's not part of pipeline. - fix headings to make each transformers and publisher under general 'Transformer' and 'Publisher' section - put rate of change transformer under it's own section similar to others - put deprecated publishers in own section for easier removal and to make deprecation more obvious. Change-Id: I2b2c2021a346062e4525bbb53bff4b8e528211c2
19 KiB
Data processing and pipelines
The mechanism by which data is processed is called a pipeline. Pipelines, at the configuration level, describe a coupling between sources of data and the corresponding sinks for transformation and publication of data. This functionality is handled by the notification agents.
A source is a producer of data: samples
or
events
. In effect, it is a set of notification handlers
emitting datapoints for a set of matching meters and event types.
Each source configuration encapsulates name matching and mapping to one or more sinks for publication.
A sink, on the other hand, is a consumer of data, providing logic for the transformation and publication of data emitted from related sources.
In effect, a sink describes a chain of handlers. The chain starts with zero or more transformers and ends with one or more publishers. The first transformer in the chain is passed data from the corresponding source, takes some action such as deriving rate of change, performing unit conversion, or aggregating, before publishing.
Pipeline configuration
The pipeline configuration is, by default stored in separate
configuration files called pipeline.yaml
and
event_pipeline.yaml
next to the
ceilometer.conf
file. The meter pipeline and event pipeline
configuration files can be set by the pipeline_cfg_file
and
event_pipeline_cfg_file
options listed in the Description
of configuration options for api table section in the OpenStack
Configuration Reference respectively. Multiple pipelines can be defined
in one pipeline configuration file.
The meter pipeline definition looks like:
---
sources:
- name: 'source name'
meters:
- 'meter filter'
sinks
- 'sink name'
sinks:
- name: 'sink name'
transformers: 'definition of transformers'
publishers:
- 'list of publishers'
There are several ways to define the list of meters for a pipeline
source. The list of valid meters can be found in telemetry-measurements
. There
is a possibility to define all the meters, or just included or excluded
meters, with which a source should operate:
- To include all meters, use the
*
wildcard symbol. It is highly advisable to select only the meters that you intend on using to avoid flooding the metering database with unused data. - To define the list of meters, use either of the following:
- To define the list of included meters, use the
meter_name
syntax. - To define the list of excluded meters, use the
!meter_name
syntax.
- To define the list of included meters, use the
Note
The OpenStack Telemetry service does not have any duplication check between pipelines, and if you add a meter to multiple pipelines then it is assumed the duplication is intentional and may be stored multiple times according to the specified sinks.
The above definition methods can be used in the following combinations:
- Use only the wildcard symbol.
- Use the list of included meters.
- Use the list of excluded meters.
- Use wildcard symbol with the list of excluded meters.
Note
At least one of the above variations should be included in the meters section. Included and excluded meters cannot co-exist in the same pipeline. Wildcard and included meters cannot co-exist in the same pipeline definition section.
The transformers section of a pipeline sink provides the possibility to add a list of transformer definitions. The available transformers are:
Name of transformer | Reference name for configuration |
---|---|
Accumulator | accumulator |
Aggregator | aggregator |
Arithmetic | arithmetic |
Rate of change | rate_of_change |
Unit conversion | unit_conversion |
Delta | delta |
The publishers section contains the list of publishers, where the samples data should be sent after the possible transformations.
Similarly, the event pipeline definition looks like:
---
sources:
- name: 'source name'
events:
- 'event filter'
sinks
- 'sink name'
sinks:
- name: 'sink name'
publishers:
- 'list of publishers'
The event filter uses the same filtering logic as the meter pipeline.
Transformers
The definition of transformers can contain the following fields:
- name
-
Name of the transformer.
- parameters
-
Parameters of the transformer.
The parameters section can contain transformer specific fields, like source and target fields with different subfields in case of the rate of change, which depends on the implementation of the transformer.
The following are supported transformers:
Rate of change transformer
Transformer that computes the change in value between two data points
in time. In the case of the transformer that creates the
cpu_util
meter, the definition looks like:
transformers:
- name: "rate_of_change"
parameters:
target:
name: "cpu_util"
unit: "%"
type: "gauge"
scale: "100.0 / (10**9 * (resource_metadata.cpu_number or 1))"
The rate of change transformer generates the cpu_util
meter from the sample values of the cpu
counter, which
represents cumulative CPU time in nanoseconds. The transformer
definition above defines a scale factor (for nanoseconds and multiple
CPUs), which is applied before the transformation derives a sequence of
gauge samples with unit %
, from sequential values of the
cpu
meter.
The definition for the disk I/O rate, which is also generated by the rate of change transformer:
transformers:
- name: "rate_of_change"
parameters:
source:
map_from:
name: "disk\\.(read|write)\\.(bytes|requests)"
unit: "(B|request)"
target:
map_to:
name: "disk.\\1.\\2.rate"
unit: "\\1/s"
type: "gauge"
Unit conversion transformer
Transformer to apply a unit conversion. It takes the volume of the
meter and multiplies it with the given scale
expression.
Also supports map_from
and map_to
like the
rate of change transformer.
Sample configuration:
transformers:
- name: "unit_conversion"
parameters:
target:
name: "disk.kilobytes"
unit: "KB"
scale: "volume * 1.0 / 1024.0"
With map_from
and map_to
:
transformers:
- name: "unit_conversion"
parameters:
source:
map_from:
name: "disk\\.(read|write)\\.bytes"
target:
map_to:
name: "disk.\\1.kilobytes"
scale: "volume * 1.0 / 1024.0"
unit: "KB"
Aggregator transformer
A transformer that sums up the incoming samples until enough samples have come in or a timeout has been reached.
Timeout can be specified with the retention_time
option.
If you want to flush the aggregation, after a set number of samples have
been aggregated, specify the size parameter.
The volume of the created sample is the sum of the volumes of samples
that came into the transformer. Samples can be aggregated by the
attributes project_id
, user_id
and
resource_metadata
. To aggregate by the chosen attributes,
specify them in the configuration and set which value of the attribute
to take for the new sample (first to take the first sample's attribute,
last to take the last sample's attribute, and drop to discard the
attribute).
To aggregate 60s worth of samples by resource_metadata
and keep the resource_metadata
of the latest received
sample:
transformers:
- name: "aggregator"
parameters:
retention_time: 60
resource_metadata: last
To aggregate each 15 samples by user_id
and
resource_metadata
and keep the user_id
of the
first received sample and drop the resource_metadata
:
transformers:
- name: "aggregator"
parameters:
size: 15
user_id: first
resource_metadata: drop
Accumulator transformer
This transformer simply caches the samples until enough samples have arrived and then flushes them all down the pipeline at once:
transformers:
- name: "accumulator"
parameters:
size: 15
Multi meter arithmetic transformer
This transformer enables us to perform arithmetic calculations over one or more meters and/or their metadata, for example:
memory_util = 100 * memory.usage / memory
A new sample is created with the properties described in the
target
section of the transformer's configuration. The
sample's volume is the result of the provided expression. The
calculation is performed on samples from the same resource.
Note
The calculation is limited to meters with the same interval.
Example configuration:
transformers:
- name: "arithmetic"
parameters:
target:
name: "memory_util"
unit: "%"
type: "gauge"
expr: "100 * $(memory.usage) / $(memory)"
To demonstrate the use of metadata, the following implementation of a novel meter shows average CPU time per core:
transformers:
- name: "arithmetic"
parameters:
target:
name: "avg_cpu_per_core"
unit: "ns"
type: "cumulative"
expr: "$(cpu) / ($(cpu).resource_metadata.cpu_number or 1)"
Note
Expression evaluation gracefully handles NaNs and exceptions. In such a case it does not create a new sample but only logs a warning.
Delta transformer
This transformer calculates the change between two sample datapoints of a resource. It can be configured to capture only the positive growth deltas.
Example configuration:
transformers:
- name: "delta"
parameters:
target:
name: "cpu.delta"
growth_only: True
Publishers
The Telemetry service provides several transport methods to transfer the data collected to an external system. The consumers of this data are widely different, like monitoring systems, for which data loss is acceptable and billing systems, which require reliable data transportation. Telemetry provides methods to fulfill the requirements of both kind of systems.
The publisher component makes it possible to save the data into persistent storage through the message bus or to send it to one or more external consumers. One chain can contain multiple publishers.
To solve this problem, the multi-publisher can be configured for each data point within the Telemetry service, allowing the same technical meter or event to be published multiple times to multiple destinations, each potentially using a different transport.
Publishers are specified in the publishers
section for
each pipeline that is defined in the pipeline.yaml
and the event_pipeline.yaml
files.
The following publisher types are supported:
gnocchi (default)
When the gnocchi publisher is enabled, measurement and resource information is pushed to gnocchi for time-series optimized storage. Gnocchi must be registered in the Identity service as Ceilometer discovers the exact path via the Identity service.
More details on how to enable and configure gnocchi can be found on its official documentation page.
panko
Event data in Ceilometer can be stored in panko which provides an
HTTP REST interface to query system events in OpenStack. To push data to
panko, set the publisher to direct://?dispatcher=panko
.
Beginning in panko's Pike release, the publisher can be set as
panko://
notifier
The notifier publisher can be specified in the form of
notifier://?option1=value1&option2=value2
. It emits
data over AMQP using oslo.messaging. Any consumer can then subscribe to
the published topic for additional processing.
Note
Prior to Ocata, the collector would consume this publisher but has since been deprecated and therefore not required.
The following customization options are available:
per_meter_topic
-
The value of this parameter is 1. It is used for publishing the samples on additional
metering_topic.sample_name
topic queue besides the defaultmetering_topic
queue. policy
-
Used for configuring the behavior for the case, when the publisher fails to send the samples, where the possible predefined values are:
- default
-
Used for waiting and blocking until the samples have been sent.
- drop
-
Used for dropping the samples which are failed to be sent.
- queue
-
Used for creating an in-memory queue and retrying to send the samples on the queue in the next samples publishing period (the queue length can be configured with
max_queue_length
, where 1024 is the default value).
topic
-
The topic name of the queue to publish to. Setting this will override the default topic defined by
metering_topic
andevent_topic
options. This option can be used to support multiple consumers.
udp
This publisher can be specified in the form of
udp://<host>:<port>/
. It emits metering data
over UDP.
file
The file publisher can be specified in the form of
file://path?option1=value1&option2=value2
. This
publisher records metering data into a file.
Note
If a file name and location is not specified, the file
publisher does not log any meters, instead it logs a warning message in
the configured log file for Telemetry.
The following options are available for the file
publisher:
max_bytes
-
When this option is greater than zero, it will cause a rollover. When the specified size is about to be exceeded, the file is closed and a new file is silently opened for output. If its value is zero, rollover never occurs.
backup_count
-
If this value is non-zero, an extension will be appended to the filename of the old log, as '.1', '.2', and so forth until the specified value is reached. The file that is written and contains the newest data is always the one that is specified without any extensions.
http
The Telemetry service supports sending samples to an external HTTP
target. The samples are sent without any modification. To set this
option as the notification agents' target, set http://
as a
publisher endpoint in the pipeline definition files. The HTTP target
should be set along with the publisher declaration. For example,
addtional configuration options can be passed in:
http://localhost:80/?option1=value1&option2=value2
The following options are availble:
timeout
-
The number of seconds before HTTP request times out.
max_retries
-
The number of times to retry a request before failing.
batch
-
If false, the publisher will send each sample and event individually, whether or not the notification agent is configured to process in batches.
poolsize
-
The maximum number of open connections the publisher will maintain. Increasing value may improve performance but will also increase memory and socket consumption requirements.
The default publisher is gnocchi
, without any additional
options specified. A sample publishers
section in the
/etc/ceilometer/pipeline.yaml
looks like the following:
publishers:
- gnocchi://
- panko://
- udp://10.0.0.2:1234
- notifier://?policy=drop&max_queue_length=512&topic=custom_target
- direct://?dispatcher=http
Deprecated publishers
The following publishers are deprecated as of Ocata and may be removed in subsequent releases.
direct
This publisher can be specified in the form of
direct://?dispatcher=http
. The dispatcher's options
include: database
, file
, http
,
and gnocchi
. It emits data in the configured dispatcher
directly, default configuration (the form is direct://
) is
database dispatcher. In the Mitaka release, this method can only emit
data to the database dispatcher, and the form is
direct://
.
kafka
Note
We recommened you use oslo.messaging if possible as it provides consistent OpenStack API.
The kafka
publisher can be specified in the form of:
kafka://kafka_broker_ip: kafka_broker_port?topic=kafka_topic &option1=value1
.
This publisher sends metering data to a kafka broker. The kafka
publisher offers similar options as notifier
publisher.
Note
If the topic parameter is missing, this publisher brings out metering
data under a topic name, ceilometer
. When the port number
is not specified, this publisher uses 9092 as the broker's port.
database
Note
This functionality was replaced by gnocchi
and
panko
publishers.
When the database dispatcher is configured as a data store, you have
the option to set a time_to_live
option (ttl) for samples.
By default the ttl value for samples is set to -1, which means that they
are kept in the database forever.
The time to live value is specified in seconds. Each sample has a
time stamp, and the ttl
value indicates that a sample will
be deleted from the database when the number of seconds has elapsed
since that sample reading was stamped. For example, if the time to live
is set to 600, all samples older than 600 seconds will be purged from
the database.
Certain databases support native TTL expiration. In cases where this
is not possible, a command-line script, which you can use for this
purpose is ceilometer-expirer
. You can run it in a cron
job, which helps to keep your database in a consistent state.
The level of support differs in case of the configured back end:
Database | TTL value support | Note |
---|---|---|
MongoDB | Yes | MongoDB has native TTL support for deleting samples that are older than the configured ttl value. |
SQL-based back ends | Yes | ceilometer-expirer has to be used for deleting samples
and its related data from the database. |
HBase | No | Telemetry's HBase support does not include native TTL nor
ceilometer-expirer support. |
DB2 NoSQL | No | DB2 NoSQL does not have native TTL nor
ceilometer-expirer support. |