This specification supports a new version of VNF lifecycle management APIs complying with ETSI NFV SOL v3. It adds a new version of APIs involved in starting VNF and terminating VNF. Change-Id: I6310d864970ff72f1677f653d743861036e79d4b Implements: blueprint support-nfv-solv3-start-and-terminate-vnf
24 KiB
Support NFV SOL_v3 starting and terminating
https://blueprints.launchpad.net/tacker/+spec/support-nfv-solv3-start-and-terminate-vnf
This specification supports a new version of VNF lifecycle management APIs complying with ETSI NFV SOL v3. It adds a new version of APIs involved in starting VNF and terminating VNF.
Problem description
ETSI specifications within the NFV Architecture Framework1 describe the main aspects of NFV development and usage based on the industry needs, feedback from SDN/NFV vendors and telecom operators. These specifications include the REST API and data model architecture which is used by NFV users and developers in related products.
Support of key ETSI NFV specifications will significantly reduce efforts for Tacker integration into Telecom production networks and also will simplify further development and support of future standards. In Wallaby release, VNF lifecycle management operations defined in ETSI NFV SOL002 v2.6.12 and SOL003 v2.6.13 are supported. However, NFV continues to develop new specifications, it should comply with multiple versions of ETSI NFV SOL specification. Tacker will support VNF lifecycle management operations defined in ETSI NFV SOL002 v3.3.14 and SOL003 v3.3.15.
Proposed change
Since the VNF lifecycle management interface version specified in ETSI NFV SOL v3 is "2.0.0", the API major version included in URI shall be set to "v2". Supporting v2 APIs involves changing the data type of some attributes and adding or removing attributes. To avoid impact on the existing implementation, APIs corresponding to "v2" should be implemented as a process independent of that of "v1".
The following are sample APIs supported by this interface.
- Create VNF Identifier
- Instantiate VNF
- Terminate VNF
- Delete VNF Identifier
1) Flow of creation of a VNF instance resource
- seqdiag {
-
Client -> "tacker-server" [label = "POST /vnflcm/v2/vnf_instances"]; "tacker-server" ->> "tacker-server" [label = "Create VNF instance resource"]; Client <-- "tacker-server" [label = "Response 201 Created"];
}
- Client sends a Create VNF request with the API major version included in URI is "v2".
- The VNFM creates a VNF instance resource and the associated VNF instance identifier.
- The VNFM returns a "201 Created" response.
If necessary, VNFM performs the package acquisition process as described in the SPEC support-sol003-vnfm-operations, and the notification process as described in the SPEC support-notification-api-based-on-etsi-nfv-sol.
2) Flow of Instantiation of a VNF instance
- seqdiag {
-
Client; NFVO; tacker-server; tacker-conductor; MgmtDriver; VnfLcmDriver;
- Client -> "tacker-server"
-
[label = "POST /vnflcm/v2/vnf_instances/{vnfInstanceId}/instantiate"];
Client <-- "tacker-server" [label = "Response 202 Accepted"]; "tacker-server" -> "tacker-conductor" [label = "trriger asynchronous task"]; NFVO <- "tacker-conductor" [label = "POST /grants"]; NFVO --> "tacker-conductor" [label = "201 Created"]; "tacker-conductor" -> "VnfLcmDriver" [label = "execute VnfLcmDriver"]; "tacker-conductor" <-- "VnfLcmDriver" [label = ""]; "tacker-conductor" -> "MgmtDriver" [label = "execute MgmtDriver"]; "tacker-conductor" <-- "MgmtDriver" [label = ""];
}
- Client sends an Instantiate VNF request with the API major version included in URI is "v2".
- The VNFM returns a "202 Accepted" response.
- VNFM and NFVO exchange granting information.
- The VNFM calls MgmtDriver and VnfLcmDriver.
If necessary, VNFM performs the notification process as described in the SPEC support-notification-api-based-on-etsi-nfv-sol.
3) Flow of Termination of a VNF instance
- seqdiag {
-
Client; NFVO; tacker-server; tacker-conductor; MgmtDriver; VnfLcmDriver;
- Client -> "tacker-server"
-
[label = "POST /vnflcm/v2/vnf_instances/{vnfInstanceId}/terminate"];
Client <-- "tacker-server" [label = "Response 202 Accepted"]; "tacker-server" -> "tacker-conductor" [label = "trriger asynchronous task"]; NFVO <- "tacker-conductor" [label = "POST /grants"]; NFVO --> "tacker-conductor" [label = "201 Created"]; "tacker-conductor" -> "MgmtDriver" [label = "execute MgmtDriver"]; "tacker-conductor" <-- "MgmtDriver" [label = ""]; "tacker-conductor" -> "VnfLcmDriver" [label = "execute VnfLcmDriver"]; "tacker-conductor" <-- "VnfLcmDriver" [label = ""];
}
- Client sends a Terminate VNF request with the API major version included in URI is "v2".
- The VNFM returns a "202 Accepted" response.
- VNFM and NFVO exchange granting information.
- The VNFM calls MgmtDriver and VnfLcmDriver.
If necessary, VNFM performs the notification process as described in the SPEC support-notification-api-based-on-etsi-nfv-sol.
4) Flow of deletion of a VNF instance resource
- seqdiag {
-
- Client -> "tacker-server"
-
[label = "DELETE /vnflcm/v2/vnf_instances/{vnfInstanceId}"];
- "tacker-server" ->> "tacker-server"
-
[label = "Delete VNF instance resource"];
Client <-- "tacker-server" [label = "Response 204 No Content"];
}
- Client sends a Delete VNF request with the API major version included in URI is "v2".
- The VNFM deletes the "VNF instance resource" and the associated VNF instance identifier.
- The VNFM returns a "204 No Content" response with an empty payload body.
If necessary, VNFM performs the notification process as described in the SPEC support-notification-api-based-on-etsi-nfv-sol.
Data model impact
In this SPEC with ETSI NFV SOL002 v3.3.1 [4] and SOL003 v3.3.1 [5], all defined attributes should be supported in API validation. Also, all data models in the response should be implemented in the Database to enable flexible change of logic in VNF lifecycle management.
From the above point of view, there are two motivations to change Database tables.
The first one is from supporting new attributes in v2 API. According to the SOL v3, new attributes were added from v2 API. However, the data model does not need to be changed because all new attributes are described in the current JSON data type.
The second one is from supporting all attributes defined in SOL documents. In v1 API, limited attributes are supported in API validation and stored in the Database. Database tables need to be changed to store additional supported attributes.
Below shows the Database tables for v2 API. As reference information, the difference with v1 API is also shown.
Note
Since Tacker manages a separate database for each major version, the design or the change of them does not affect each other.
VnfInstance
v1 API (vnf_instances) v2 API (VnfInstanceV2) Changes from v1 API Data type id id Data type changed varchar(36) NOT NULL -> varchar(255) NOT NULL vnf_instance_name vnfInstanceName Renamed <no_changed> vnf_instance_description vnfInstanceDescription Renamed and Data type changed varchar(1024) DEFAULT NULL -> text DEFAULT NULL vnfd_id vnfdId Renamed and Data type changed varchar(36) NOT NULL -> varchar(255) NOT NULL vnf_provider vnfProvider Renamed <no_changed> vnf_product_name vnfProductName Renamed <no_changed> vnf_software_version vnfSoftwareVersion Renamed <no_changed> vnfd_version vnfdVersion Renamed <no_changed> vnfConfigurableProperties Added json DEFAULT NULL vim_connection_info vimConnectionInfo Renamed <no_changed> instantiation_state instantiationState Data type changed varchar(255) NOT NULL -> enum('NOT_INSTANTIATED','INSTANTIATED') NOT NULL instantiatedVnfInfo Added
instantiatedVnfInfo field corresponding to vnf_instantiated_info in v1 API is merged in VnfInstanceV2 table and json data is stored directly.json DEFAULT NULL vnf_metadata metadata Renamed <no_changed> extensions Added json DEFAULT NULL task_state Deleted tenant_id Deleted vnf_pkg_id Deleted created_at Deleted updated_at Deleted deleted_at Deleted deleted Deleted VnfLcmOpOcc
v1 API (vnf_lcm_op_occs) v2 API (VnfLcmOpOccV2) Changes from v1 API Data type id id Data type changed varchar(36) NOT NULL -> varchar(255) NOT NULL operation_state operationState Renamed and Data type changed varchar(16) DEFAULT NULL -> enum('STARTING','PROCESSING','COMPLETED','FAILED_TEMP','FAILED','ROLLING_BACK','ROLLED_BACK') NOT NULL state_entered_time stateEnteredTime Renamed <no_changed> start_time startTime Renamed <no_changed> vnf_instance_id vnfInstanceId Renamed and Data type changed varchar(36) NOT NULL -> varchar(255) NOT NULL grant_id grantId Data type changed varchar(36) NOT NULL -> varchar(255) NOT NULL operation operation Data type changed varchar(16) DEFAULT NULL -> enum('INSTANTIATE','SCALE','SCALE_TO_LEVEL','CHANGE_FLAVOUR','TERMINATE','HEAL','OPERATE','CHANGE_EXT_CONN','MODIFY_INFO','CREATE_SNAPSHOT','REVERT_TO_SNAPSHOT','CHANGE_VNFPKG') NOT NULL is_automatic_invocation isAutomaticInvocation Renamed <no_changed> operation_params operationParams Renamed <no_changed> is_cancel_pending isCancelPending Renamed <no_changed> cancelMode Added enum('GRACEFUL','FORCEFUL') DEFAULT NULL error error <no_changed> <no_changed> resource_changes resourceChanges Renamed <no_changed> changed_info changedInfo Renamed <no_changed> changed_ext_connectivity changedExtConnectivity Renamed <no_changed> modificationsTriggeredByVnfPkgChange Added
New field defined SOL003 v3.3.16 "F.2.1 FEAT02: VNF Software modification".json DEFAULT NULL vnfSnapshotInfoId Added
New field defined SOL003 v3.3.17 "F.2.4 FEAT15: VNF snapshotting".varchar(255) DEFAULT NULL error_point Deleted created_at Deleted updated_at Deleted deleted_at Deleted deleted Deleted
REST API impact
All defined attributes should be supported in API validation. The "_link" attribute is the only exception because not all operations in VNF lifecycle management interface are implemented. Some links to not implemented operations should be filtered.
- Name: Create VNF Identifier
Description: Creates a new VNF instance resource
Method type: POST
URL for the resource: /vnflcm/v2/vnf_instances
Request:Data type Cardinality Description CreateVnfRequest 1 The VNF creation parameters. Attribute name Data type Cardinality Supported in API v2 (Xena) Supported in API v1 (Wallaby) vnfdId Identifier 1 Yes Yes vnfInstanceName String 0..1 Yes Yes vnfInstanceDescription String 0..1 Yes Yes metadata KeyValuePairs 0..1 Yes Yes Response:Data type Cardinality Response Codes Description VnfInstance 1 Success: 201 A VNF Instance identifier was created successfully. ProblemDetails 1 Error: 422 The content type of the payload body is supported and the payload body of a request contains syntactically correct data but the data cannot be processed. ProblemDetails See clause 6.4 of8 Error: 4xx, 5xx Any common error response code as defined in clause 6.4 of ETSI GS NFV-SOL 0139 may be returned. Attribute name Data type Cardinality Supported in API v2 (Xena) Supported in API v1 (Wallaby) Description id Identifier 1 Yes Yes vnfInstanceName String 0..1 Yes Yes vnfInstanceDescription String 0..1 Yes Yes vnfdId Identifier 1 Yes Yes vnfProvider String 1 Yes Yes vnfProductName String 1 Yes Yes vnfSoftwareVersion Version 1 Yes Yes vnfdVersion Version 1 Yes Yes vnfConfigurableProperties KeyValuePairs 0..1 Yes No vimConnectionInfo map(VimConnectionInfo) 0..N Yes Yes In API v2, the Data type is changed from VimConnectionInfo to map(VimConnectionInfo). instantiationState Enum 1 Yes Yes metadata KeyValuePairs 0..1 Yes No extensions KeyValuePairs 0..1 Yes No _links Structure (inlined) 1 Yes Yes >self Link 1 Yes Yes >indicators Link 0..1 No No >instantiate Link 0..1 Yes Yes >terminate Link 0..1 Yes Yes >scale Link 0..1 Yes Yes >scaleToLevel Link 0..1 No No >changeFlavour Link 0..1 No No >heal Link 0..1 Yes Yes >operate Link 0..1 No No >changeExtConn Link 0..1 Yes Yes >createSnapshot Link 0..1 No New attribute in API v2. >revertToSnapshot Link 0..1 No New attribute in API v2. - Name: Instantiate VNF task
Description: This task resource represents the "Instantiate VNF" operation. The client can use this resource to instantiate a VNF instance.
Method type: POST
URL for the resource: /vnflcm/v2/vnf_instances/{vnfInstanceId}/instantiate
Resource URI variables for this resource:Name Definition vnfInstanceId The identifier of the VNF instance to be instantiated. Request:Data type Cardinality Description InstantiateVnfRequest 1 Parameters passed to instantiate task. Attribute name Data type Cardinality Supported in API v2 (Xena) Supported in API v1 (Wallaby) Description flavourId IdentifierInVnfd 1 Yes Yes instantiationLevelId IdentifierInVnfd 0..1 Yes Yes extVirtualLinks ExtVirtualLinkData 0..N Yes Yes extManagedVirtualLinks ExtManagedVirtualLinkData 0..N Yes Yes vimConnectionInfo map(VimConnectionInfo) 0..N Yes Yes In API v2, the Data type is changed from VimConnectionInfo to map(VimConnectionInfo). localizationLanguage String 0..1 Yes No additionalParams KeyValuePairs 0..1 Yes Yes extensions KeyValuePairs 0..1 Yes No vnfConfigurableProperties KeyValuePairs 0..1 Yes No Response:Data type Cardinality Response Codes Description n/a Success: 202 The request was accepted for processing, but the processing has not been completed. ProblemDetails 1 Error: 409 The operation cannot be executed currently, due to a conflict with the state of the resource. ProblemDetails See clause 6.4 of10 Error: 4xx, 5xx Any common error response code as defined in clause 6.4 of ETSI GS NFV-SOL 01311 may be returned. - Name: Terminate VNF task
Description: This task resource represents the "Terminate VNF" operation. The client can use this resource to terminate a VNF instance.
Method type: POST
URL for the resource: /vnflcm/v2/vnf_instances/{vnfInstanceId}/terminate
Resource URI variables for this resource:Name Description vnfInstanceId The identifier of the VNF instance to be terminated. Request:Data type Cardinality Description TerminateVnfRequest 1 Parameters passed to Terminate VNF task. Attribute name Data type Cardinality Supported in API v2 (Xena) Supported in API v1 (Wallaby) terminationType Enum (inlined) 1 Yes Yes gracefulTerminationTimeout Integer 0..1 Yes Yes additionalParams KeyValuePairs 0..1 Yes Yes Response:Data type Cardinality Response Codes Description n/a Success: 202 The request was accepted for processing, but the processing has not been completed. ProblemDetails See clause 6.4 of12 Error: 4xx, 5xx Any common error response code as defined in clause 6.4 of ETSI GS NFV-SOL 01313 may be returned. - Name: Delete VNF Instance
Description: Request to delete VNF instance resource by its id
Method type: DELETE
URL for the resource: /vnflcm/v2/vnf_instances/{vnfInstanceId}
Resource URI variables for this resource:Name Description vnfInstanceId Identifier of the VNF instance. Response:Data type Cardinality Response Codes Description n/a Success: 204 The VNF instance resource and the associated VNF identifier were deleted successfully. ProblemDetails 1 Error: 409 The operation cannot be executed currently, due to a conflict with the state of the resource. ProblemDetails See clause 6.4 of14 Error: 4xx, 5xx Any common error response code as defined in clause 6.4 of ETSI GS NFV-SOL 01315 may be returned.
Security impact
None
Notifications impact
None
Other end user impact
CLI options may be changed to switch between v1 API and v2 API.
Performance Impact
None
Other deployer impact
None
Developer impact
- python-tackerclient needs to support a new attribute to set API version.
Implementation
Assignee(s)
Hirofumi Noguchi <hirofumi.noguchi.rs@hco.ntt.co.jp>
Work Items
- Add new version API endpoints to Tacker-server.
- Add new unit and functional tests.
- Update the Tacker's API documentation.
Dependencies
None
Testing
Unit and functional test cases will be added for VNF lifecycle management of VNF instances.
Documentation Impact
Complete user guide will be added to explain how to invoke VNF lifecycle management of VNF instances with examples.
References
https://www.etsi.org/technologies-clusters/technologies/NFV↩︎
https://www.etsi.org/deliver/etsi_gs/NFV-SOL/001_099/002/02.06.01_60/gs_nfv-sol002v020601p.pdf (Chapter 5: VNF Lifecycle Management interface)↩︎
https://www.etsi.org/deliver/etsi_gs/NFV-SOL/001_099/003/02.06.01_60/gs_nfv-sol003v020601p.pdf (Chapter 5: VNF Lifecycle Management interface)↩︎
https://www.etsi.org/deliver/etsi_gs/NFV-SOL/001_099/002/03.03.01_60/gs_nfv-sol002v030301p.pdf (Chapter 5: VNF Lifecycle Management interface)↩︎
https://www.etsi.org/deliver/etsi_gs/NFV-SOL/001_099/003/03.03.01_60/gs_nfv-sol003v030301p.pdf (Chapter 5: VNF Lifecycle Management interface)↩︎
https://www.etsi.org/deliver/etsi_gs/NFV-SOL/001_099/003/03.03.01_60/gs_nfv-sol003v030301p.pdf (Chapter 5: VNF Lifecycle Management interface)↩︎
https://www.etsi.org/deliver/etsi_gs/NFV-SOL/001_099/003/03.03.01_60/gs_nfv-sol003v030301p.pdf (Chapter 5: VNF Lifecycle Management interface)↩︎
https://www.etsi.org/deliver/etsi_gs/NFV-SOL/001_099/013/03.04.01_60/gs_nfv-sol013v030401p.pdf↩︎
https://www.etsi.org/deliver/etsi_gs/NFV-SOL/001_099/013/03.04.01_60/gs_nfv-sol013v030401p.pdf↩︎
https://www.etsi.org/deliver/etsi_gs/NFV-SOL/001_099/013/03.04.01_60/gs_nfv-sol013v030401p.pdf↩︎
https://www.etsi.org/deliver/etsi_gs/NFV-SOL/001_099/013/03.04.01_60/gs_nfv-sol013v030401p.pdf↩︎
https://www.etsi.org/deliver/etsi_gs/NFV-SOL/001_099/013/03.04.01_60/gs_nfv-sol013v030401p.pdf↩︎
https://www.etsi.org/deliver/etsi_gs/NFV-SOL/001_099/013/03.04.01_60/gs_nfv-sol013v030401p.pdf↩︎
https://www.etsi.org/deliver/etsi_gs/NFV-SOL/001_099/013/03.04.01_60/gs_nfv-sol013v030401p.pdf↩︎