Baremetal Environment
---------------------
|project| can be used in an all baremetal environment. One machine will be
used for Undercloud, the others will be used for your Overcloud.
Minimum System Requirements
^^^^^^^^^^^^^^^^^^^^^^^^^^^
To deploy a minimal TripleO cloud with |project| you need the following baremetal
machines:
* 1 Undercloud
* 1 Overcloud Controller
* 1 Overcloud Compute
For each additional Overcloud role, such as Block Storage or Object Storage,
you need an additional baremetal machine.
..
<REMOVE WHEN HA IS AVAILABLE>
For minimal **HA (high availability)** deployment you need at least 3 Overcloud
Controller machines and 2 Overcloud Compute machines.
The baremetal machines must meet the following minimum specifications:
* 8 core CPU
* 12 GB memory
* 60 GB free disk space
Larger systems are recommended for production deployments, however.
For instance, the undercloud needs a bit more capacity, especially regarding RAM (minimum of 16G is advised)
and is pretty intense for the I/O - fast disks (SSD, SAS) are strongly advised.
Please also note the undercloud needs space in order to store twice the "overcloud-full" image (one time
in its glance, one time in /var/lib subdirectories for PXE/TFTP).
TripleO is supporting only the following operating systems:
* RHEL 7 x86_64
* CentOS 7 x86_64
Please also ensure your node clock is set to UTC in order to prevent any issue
when the OS hwclock syncs to the BIOS clock before applying timezone offset,
causing files to have a future-dated timestamp.
Preparing the Baremetal Environment
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
Networking
^^^^^^^^^^
The overcloud nodes will be deployed from the undercloud machine and therefore the machines need to have have their network settings modified to allow for the overcloud nodes to be PXE boot'ed using the undercloud machine. As such, the setup requires that:
* All overcloud machines in the setup must support IPMI
* A management provisioning network is setup for all of the overcloud machines.
One NIC from every machine needs to be in the same broadcast domain of the
provisioning network. In the tested environment, this required setting up a new
VLAN on the switch. Note that you should use the same NIC on each of the
overcloud machines ( for example: use the second NIC on each overcloud
machine). This is because during installation we will need to refer to that NIC
using a single name across all overcloud machines e.g. em2
* The provisioning network NIC should not be the same NIC that you are using
for remote connectivity to the undercloud machine. During the undercloud
installation, a openvswitch bridge will be created for Neutron and the
provisioning NIC will be bridged to the openvswitch bridge. As such,
connectivity would be lost if the provisioning NIC was also used for remote
connectivity to the undercloud machine.
* The overcloud machines can PXE boot off the NIC that is on the private VLAN.
In the tested environment, this required disabling network booting in the BIOS
for all NICs other than the one we wanted to boot and then ensuring that the
chosen NIC is at the top of the boot order (ahead of the local hard disk drive
and CD/DVD drives).
* For each overcloud machine you have: the MAC address of the NIC that will PXE
boot on the provisioning network the IPMI information for the machine (i.e. IP
address of the IPMI NIC, IPMI username and password)
Refer to the following diagram for more information
.. image:: ../_images/TripleO_Network_Diagram_.jpg
Setting Up The Undercloud Machine
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
#. Select a machine within the baremetal environment on which to install the
undercloud.
#. Install RHEL 7.1 x86_64 or CentOS 7 x86_64 on this machine.
#. If needed, create a non-root user with sudo access to use for installing the
Undercloud::
sudo useradd stack
sudo passwd stack # specify a password
echo "stack ALL=(root) NOPASSWD:ALL" | sudo tee -a /etc/sudoers.d/stack
sudo chmod 0440 /etc/sudoers.d/stack
.. admonition:: RHEL
:class: rhel
If using RHEL, register the Undercloud for package installations/updates.
.. admonition:: RHEL Portal Registration
:class: portal
Register the host machine using Subscription Management::
sudo subscription-manager register --username="[your username]" --password="[your password]"
# Find this with `subscription-manager list --available`
sudo subscription-manager attach --pool="[pool id]"
# Verify repositories are available
sudo subscription-manager repos --list
# Enable repositories needed
sudo subscription-manager repos --enable=rhel-7-server-rpms \
--enable=rhel-7-server-optional-rpms --enable=rhel-7-server-extras-rpms \
--enable=rhel-7-server-openstack-6.0-rpms
.. admonition:: RHEL Satellite Registration
:class: satellite
To register the host machine to a Satellite, the following repos must
be synchronized on the Satellite and enabled for registered systems::
rhel-7-server-rpms
rhel-7-server-optional-rpms
rhel-7-server-extras-rpms
rhel-7-server-openstack-6.0-rpms
See the `Red Hat Satellite User Guide`_ for how to configure the system to
register with a Satellite server. It is suggested to use an activation
key that automatically enables the above repos for registered systems.
.. _Red Hat Satellite User Guide: https://access.redhat.com/documentation/en-US/Red_Hat_Satellite/
Validations
^^^^^^^^^^^
You can run the ``prep`` validations to verify the hardware. Later in
the process, the validations will be run by the undercloud processes.
Refer to the Ansible section for running directly the validations
over baremetal nodes `validations_no_undercloud`_.
Configuration Files
^^^^^^^^^^^^^^^^^^^
.. _instackenv:
instackenv.json
^^^^^^^^^^^^^^^
Create a JSON file describing your Overcloud baremetal nodes, call it
``instackenv.json`` and place in your home directory. The file should contain
a JSON object with the only field ``nodes`` containing list of node
descriptions.
Each node description should contains required fields:
* ``pm_type`` - driver for Ironic nodes, see `Ironic Hardware Types`_
for details
* ``pm_addr`` - node BMC IP address (hypervisor address in case of virtual
environment)
* ``pm_user``, ``pm_password`` - node BMC credentials
Some fields are optional if you're going to use introspection later:
* ``ports`` - list of baremetal port objects, a map specifying the following
keys: address, physical_network (optional) and local_link_connection
(optional). Optional for bare metal. Example::
"ports": [
{
"address": "52:54:00:87:c8:2f",
"physical_network": "physical-network",
"local_link_connection": {
"switch_info": "switch",
"port_id": "gi1/0/11",
"switch_id": "a6:18:66:33:cb:48"
}
}
]
* ``cpu`` - number of CPU's in system
* ``arch`` - CPU architecture (common values are ``i386`` and ``x86_64``)
* ``memory`` - memory size in MiB
* ``disk`` - hard driver size in GiB
It is also possible (but optional) to set Ironic node capabilities directly
in the JSON file. This can be useful for assigning node profiles or setting
boot options at registration time:
* ``capabilities`` - Ironic node capabilities. For example::
"capabilities": "profile:compute,boot_option:local"
There are also two additional and optional fields that can be used to help a
user identifying machines inside ``instackenv.json`` file:
* ``name`` - name associated to the node, it will appear in the ``Name``
column while listing nodes
* ``_comment`` to associate a comment to the node (like position, long
description and so on). Note that this field will not be considered by
Ironic during the import
Also if you're working in a diverse environment with multiple architectures
and/or platforms within an architecture you may find it necessary to include a
platform field:
* ``platform`` - String paired with images to fine tune image selection
For example::
{
"nodes": [
{
"name": "node-a",
"pm_type": "ipmi",
"ports": [
{
"address": "fa:16:3e:2a:0e:36",
"physical_network": "ctlplane"
}
],
"cpu": "2",
"memory": "4096",
"disk": "40",
"arch": "x86_64",
"pm_user": "admin",
"pm_password": "password",
"pm_addr": "10.0.0.8",
"_comment": "Room 1 - Rack A - Unit 22/24"
},
{
"name": "node-b",
"pm_type": "ipmi",
"ports": [
{
"address": "fa:16:3e:da:39:c9",
"physical_network": "ctlplane"
}
],
"cpu": "2",
"memory": "4096",
"disk": "40",
"arch": "x86_64",
"pm_user": "admin",
"pm_password": "password",
"pm_addr": "10.0.0.15",
"_comment": "Room 1 - Rack A - Unit 26/28"
},
{
"name": "node-n",
"pm_type": "ipmi",
"ports": [
{
"address": "fa:16:3e:51:9b:68",
"physical_network": "leaf1"
}
],
"cpu": "2",
"memory": "4096",
"disk": "40",
"arch": "x86_64",
"pm_user": "admin",
"pm_password": "password",
"pm_addr": "10.0.0.16",
"_comment": "Room 1 - Rack B - Unit 10/12"
}
]
}
.. note::
You don't need to create this file, if you plan on using
:doc:`../provisioning/node_discovery`.
Ironic Hardware Types
^^^^^^^^^^^^^^^^^^^^^
Ironic *hardware types* provide various level of support for different
hardware. Hardware types, introduced in the Ocata cycle, are a new generation
of Ironic *drivers*. Previously, the word *drivers* was used to refer to what
is now called *classic drivers*. See `Ironic drivers documentation`_ for a full
explanation of similarities and differences between the two types.
Hardware types are enabled in the ``undercloud.conf`` using the
``enabled_hardware_types`` configuration option. Classic drivers are enabled
using the ``enabled_drivers`` option. It has been deprecated since the Queens
release and should no longer be used. See the `hardware types migration guide`_
for information on how to migrate existing nodes.
Both hardware types and classic drivers can be equally used in the
``pm_addr`` field of the ``instackenv.json``.
See https://docs.openstack.org/ironic/latest/admin/drivers.html for the most
up-to-date information about Ironic hardware types and hardware
interfaces, but note that this page always targets Ironic git master, not the
release we use.
Generic Hardware Types
~~~~~~~~~~~~~~~~~~~~~~~
* This most generic hardware type is ipmi_. It uses the `ipmitool`_ utility
to manage a bare metal node, and supports a vast variety of hardware.
.. admonition:: Stable Branch
:class: stable
This hardware type is supported starting with the Pike release. For older
releases use the functionally equivalent ``pxe_ipmitool`` driver.
.. admonition:: Virtual
:class: virtual
When combined with :doc:`virtualbmc`, this hardware type can be used for
developing and testing TripleO in a virtual environment as well.
.. admonition:: Stable Branch
:class: stable
Prior to the Ocata release, a special ``pxe_ssh`` driver was used for
testing Ironic in the virtual environment. This driver connects to the
hypervisor to conduct management operations on virtual nodes. In case
of this driver, ``pm_addr`` is a hypervisor address, ``pm_user`` is
a SSH user name for accessing hypervisor, ``pm_password`` is a private
SSH key for accessing hypervisor. Note that private key must not be
encrypted.
.. warning::
The ``pxe_ssh`` driver is deprecated and ``pxe_ipmitool`` +
:doc:`virtualbmc` should be used instead.
* Another generic hardware type is redfish_. It provides support for the
quite new `Redfish standard`_, which aims to replace IPMI eventually as
a generic protocol for managing hardware. In addition to the ``pm_*`` fields
mentioned above, this hardware type also requires setting ``pm_system_id``
to the full identifier of the node in the controller (e.g.
``/redfish/v1/Systems/42``).
.. admonition:: Stable Branch
:class: stable
Redfish support was introduced in the Pike release.
The following generic hardware types are not enabled by default:
* The snmp_ hardware type supports controlling PDUs for power management.
It requires boot device to be manually configured on the nodes.
* Finally, the ``manual-management`` hardware type (not enabled by default)
skips power and boot device management completely. It requires manual power
and boot operations to be done at the right moments, so it's not recommended
for a generic production.
.. admonition:: Stable Branch
:class: stable
The functional analog of this hardware type before the Queens release
was the ``fake_pxe`` driver.
Vendor Hardware Types
~~~~~~~~~~~~~~~~~~~~~
TripleO also supports vendor-specific hardware types for some types
of hardware:
* ilo_ targets HPE Proliant Gen 8 and Gen 9 systems.
.. admonition:: Stable Branch
:class: stable
Use the ``pxe_ilo`` classic driver before the Queens release.
* idrac_ targets DELL 12G and newer systems.
.. admonition:: Stable Branch
:class: stable
Use the ``pxe_drac`` classic driver before the Queens release.
The following hardware types are supported but not enabled by default:
* irmc_ targets FUJITSU PRIMERGY servers.
* cisco-ucs-managed_ targets UCS Manager managed Cisco UCS B/C series servers.
* cisco-ucs-standalone_ targets standalone Cisco UCS C series servers.
.. note::
Contact a specific vendor team if you have problems with any of these
drivers, as the TripleO team often cannot assist with them.
.. _Ironic drivers documentation: https://docs.openstack.org/ironic/latest/install/enabling-drivers.html
.. _hardware types migration guide: https://docs.openstack.org/ironic/latest/admin/upgrade-to-hardware-types.html
.. _ipmitool: http://sourceforge.net/projects/ipmitool/
.. _Redfish standard: https://www.dmtf.org/standards/redfish
.. _ipmi: https://docs.openstack.org/ironic/latest/admin/drivers/ipmitool.html
.. _redfish: https://docs.openstack.org/ironic/latest/admin/drivers/redfish.html
.. _snmp: https://docs.openstack.org/ironic/latest/admin/drivers/snmp.html
.. _ilo: https://docs.openstack.org/ironic/latest/admin/drivers/ilo.html
.. _idrac: https://docs.openstack.org/ironic/latest/admin/drivers/idrac.html
.. _irmc: https://docs.openstack.org/ironic/latest/admin/drivers/irmc.html
.. _cisco-ucs-managed: https://docs.openstack.org/ironic/latest/admin/drivers/ucs.html
.. _cisco-ucs-standalone: https://docs.openstack.org/ironic/latest/admin/drivers/cimc.html
.. _validations_no_undercloud: ../../validations/ansible.html