Support for HPE Synergy compute module (dsR8) - draft

Create .rest files and fix link in table.

Signed-off-by: Elisamara Aoki Goncalves <elisamaraaoki.goncalves@windriver.com>
Change-Id: I2ab179aa3716c9e74876ee9e084b7f7b0ceec36c
This commit is contained in:
Elisamara Aoki Goncalves 2023-03-30 15:55:14 -03:00
parent cf558baf2c
commit 9410dd0488
5 changed files with 92 additions and 24 deletions

View File

@ -0,0 +1,2 @@
.. note-begin
.. note-end

View File

@ -0,0 +1,5 @@
.. hpe-begin
.. hpe-end
.. hard-drive-begin
.. hard-drive-end

View File

@ -21,7 +21,7 @@ host types are:
.. end-min-hw-reqs-common-intro
..
..
.. Simplex
..
@ -48,7 +48,7 @@ host types are:
default, configurable)
Application: Remaining cores
* - Minimum memory
- 64 GB
@ -57,16 +57,26 @@ host types are:
* Platform:
- Socket 0: 7GB (by default, configurable)
- Socket 1: 1GB (by default, configurable)
* Application:
- Socket 0: Remaining memory
- Socket 1: Remaining memory
* - Primary disk
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
.. only:: starlingx
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
.. only:: partner
.. include:: /_includes/prepare-servers-for-installation-91baad307173.rest
:start-after: primary-disk-begin
:end-before: primary-disk-end
* - Additional disks
- * 1 or more 500 GB (min. 10K RPM) for Ceph |OSD|
@ -99,7 +109,7 @@ host types are:
* - USB Interface
- 1 (Only required if used for initial installation of controller-0)
* - Boot Order
- HD, PXE, USB
@ -107,7 +117,7 @@ host types are:
- BIOS or |UEFI|
.. note::
.. note::
|UEFI Secure Boot and |UEFI| |PXE| boot over IPv6 are not
supported. On systems with an IPv6 management network, you can use
@ -122,7 +132,7 @@ host types are:
* VT for directed I/O enabled
* CPU power and performance policy set to performance
* |min-proc-idle-power| CPU C state control disabled
* Plug & play |BMC| detection disabled
@ -149,7 +159,7 @@ Prepare bare metal servers
.. end-prepare-servers
..
..
.. Duplex
..
@ -187,7 +197,17 @@ host types are:
* - Minimum memory
- 64 GB
* - Primary disk
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
.. only:: starlingx
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
.. only:: partner
.. include:: /_includes/prepare-servers-for-installation-91baad307173.rest
:start-after: primary-disk-begin
:end-before: primary-disk-end
* - Additional disks
- * 1 or more 500 GB (min. 10K RPM) for Ceph |OSD|
@ -231,7 +251,7 @@ Prepare bare metal servers
.. end-prepare-servers-dx
..
..
.. Standard with storage
..
@ -255,6 +275,7 @@ configuration.
Minimum hardware requirements
-----------------------------
The recommended minimum hardware requirements for bare metal servers for various
host types are:
@ -274,7 +295,17 @@ host types are:
- 64 GB
- 32 GB
* - Primary disk
- 500 GB SSD or |NVMe| (see Configure |NVMe| Drive as Primary Disk)
.. only:: starlingx
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
.. only:: partner
.. include:: /_includes/prepare-servers-for-installation-91baad307173.rest
:start-after: primary-disk-begin
:end-before: primary-disk-end
- 120 GB (Minimum 10k RPM)
* - Additional disks
- * 1 or more 500 GB (min. 10K RPM) for Ceph |OSD|
@ -322,7 +353,7 @@ Prepare bare metal servers
.. end-prepare-servers-std
..
..
.. Dedicated storage
..
@ -360,7 +391,7 @@ host types are:
- 2-9
- 2-100
* - Minimum processor class
- Dual-CPU Intel® Xeon® E5 26xx family (SandyBridge) 8 cores/socket
- Dual-CPU Intel® Xeon® E5 26xx family (SandyBridge) 8 cores/socket
- (Same as controller node)
- (Same as controller node)
* - Minimum memory
@ -368,7 +399,16 @@ host types are:
- 64 GB
- 32 GB
* - Primary disk
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
.. only:: starlingx
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
.. only:: partner
.. include:: /_includes/prepare-servers-for-installation-91baad307173.rest
:start-after: primary-disk-begin
:end-before: primary-disk-end
- 120 GB (min. 10k RPM)
- 120 GB (min. 10k RPM)
* - Additional disks
@ -389,15 +429,15 @@ host types are:
* Data: 1 or more x 10GE
* - Bios settings
- * Hyper-Threading technology enabled
* Virtualization technology enabled
* VT for directed I/O enabled
* CPU power and performance policy set to performance
* CPU C state control disabled
* Plug & play |BMC| detection disabled
- (Same as controller node)
- (Same as controller node)

View File

@ -44,5 +44,11 @@ persistent volume claim or container-ephemeral storage.
| | /dev/sdc | | | | | | | AIO-SX:superscript:`1:` (replication = 2) ; AIO-DX (replication = 2) |
+--------------+----------+-----------+-----------+-----------+-----------------------------------------------+-----------------------------+-------------------+-------------------------------------------------------------------------+
.. only:: partner
.. include:: /_includes/controller-disk-configurations-for-all-in-one-systems.rest
:start-after: note-begin
:end-before: note-end
.. [#fntarg1] |AIO|-Simplex Ceph replication is disk-based.

View File

@ -6,8 +6,16 @@
Hard Drive Options
==================
For hard drive storage, |prod| supports high-performance |SSD| and |NVMe|
drives as well as rotational disks.
.. only:: starlingx
For hard drive storage, |prod| supports high-performance |SSD| and |NVMe|
drives as well as rotational disks.
.. only:: partner
.. include:: /_includes/hard-drive-options.rest
:start-after: hpe-begin
:end-before: hpe-end
To increase system performance, you can use a |SSD| or a |NVMe| drive on |prod|
hosts in place of any rotational drive. |SSD| provides faster read-write access
@ -26,3 +34,10 @@ adapters is required.
To use an |NVMe| drive as a root drive, you must enable |UEFI| support in the
host BIOS. In addition, when installing the host, you must perform extra steps
to assign the drive as the boot device.
.. only:: partner
.. include:: /_includes/hard-drive-options.rest
:start-after: hard-drive-begin
:end-before: hard-drive-end