Support for HPE Synergy compute module (dsR8) - draft

Create .rest files and fix link in table.

Signed-off-by: Elisamara Aoki Goncalves <elisamaraaoki.goncalves@windriver.com>
Change-Id: I2ab179aa3716c9e74876ee9e084b7f7b0ceec36c
This commit is contained in:
Elisamara Aoki Goncalves 2023-03-30 15:55:14 -03:00
parent cf558baf2c
commit 9410dd0488
5 changed files with 92 additions and 24 deletions

View File

@ -0,0 +1,2 @@
.. note-begin
.. note-end

View File

@ -0,0 +1,5 @@
.. hpe-begin
.. hpe-end
.. hard-drive-begin
.. hard-drive-end

View File

@ -66,7 +66,17 @@ host types are:
- Socket 1: Remaining memory
* - Primary disk
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
.. only:: starlingx
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
.. only:: partner
.. include:: /_includes/prepare-servers-for-installation-91baad307173.rest
:start-after: primary-disk-begin
:end-before: primary-disk-end
* - Additional disks
- * 1 or more 500 GB (min. 10K RPM) for Ceph |OSD|
@ -187,7 +197,17 @@ host types are:
* - Minimum memory
- 64 GB
* - Primary disk
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
.. only:: starlingx
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
.. only:: partner
.. include:: /_includes/prepare-servers-for-installation-91baad307173.rest
:start-after: primary-disk-begin
:end-before: primary-disk-end
* - Additional disks
- * 1 or more 500 GB (min. 10K RPM) for Ceph |OSD|
@ -255,6 +275,7 @@ configuration.
Minimum hardware requirements
-----------------------------
The recommended minimum hardware requirements for bare metal servers for various
host types are:
@ -274,7 +295,17 @@ host types are:
- 64 GB
- 32 GB
* - Primary disk
- 500 GB SSD or |NVMe| (see Configure |NVMe| Drive as Primary Disk)
.. only:: starlingx
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
.. only:: partner
.. include:: /_includes/prepare-servers-for-installation-91baad307173.rest
:start-after: primary-disk-begin
:end-before: primary-disk-end
- 120 GB (Minimum 10k RPM)
* - Additional disks
- * 1 or more 500 GB (min. 10K RPM) for Ceph |OSD|
@ -368,7 +399,16 @@ host types are:
- 64 GB
- 32 GB
* - Primary disk
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
.. only:: starlingx
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
.. only:: partner
.. include:: /_includes/prepare-servers-for-installation-91baad307173.rest
:start-after: primary-disk-begin
:end-before: primary-disk-end
- 120 GB (min. 10k RPM)
- 120 GB (min. 10k RPM)
* - Additional disks

View File

@ -44,5 +44,11 @@ persistent volume claim or container-ephemeral storage.
| | /dev/sdc | | | | | | | AIO-SX:superscript:`1:` (replication = 2) ; AIO-DX (replication = 2) |
+--------------+----------+-----------+-----------+-----------+-----------------------------------------------+-----------------------------+-------------------+-------------------------------------------------------------------------+
.. only:: partner
.. include:: /_includes/controller-disk-configurations-for-all-in-one-systems.rest
:start-after: note-begin
:end-before: note-end
.. [#fntarg1] |AIO|-Simplex Ceph replication is disk-based.

View File

@ -6,8 +6,16 @@
Hard Drive Options
==================
For hard drive storage, |prod| supports high-performance |SSD| and |NVMe|
drives as well as rotational disks.
.. only:: starlingx
For hard drive storage, |prod| supports high-performance |SSD| and |NVMe|
drives as well as rotational disks.
.. only:: partner
.. include:: /_includes/hard-drive-options.rest
:start-after: hpe-begin
:end-before: hpe-end
To increase system performance, you can use a |SSD| or a |NVMe| drive on |prod|
hosts in place of any rotational drive. |SSD| provides faster read-write access
@ -26,3 +34,10 @@ adapters is required.
To use an |NVMe| drive as a root drive, you must enable |UEFI| support in the
host BIOS. In addition, when installing the host, you must perform extra steps
to assign the drive as the boot device.
.. only:: partner
.. include:: /_includes/hard-drive-options.rest
:start-after: hard-drive-begin
:end-before: hard-drive-end