100 Series Alarm Messages

The system inventory and maintenance service reports system changes with different degrees of severity. Use the reported alarms to monitor the overall health of the system.

Alarm ID: 100.101

Platform CPU threshold exceeded; threshold x%, actual y%. CRITICAL @ 95%

MAJOR @ 90%

Entity Instance host=<hostname>
Degrade Affecting Severity: Critical
Severity: C/M*
Proposed Repair Action Monitor and if condition persists, contact next level of support.

Alarm ID: 100.103

Memory threshold exceeded; threshold x%, actual y% .

CRITICAL @ 90%

MAJOR @ 80%

Entity Instance host=<hostname>
Degrade Affecting Severity: Critical
Severity: C/M
Proposed Repair Action Monitor and if condition persists, contact next level of support; may require additional memory on Host.

Alarm ID: 100.104

host=<hostname>.filesystem=<mount-dir> File System threshold exceeded; threshold x%, actual y%.

CRITICAL @ 90%

MAJOR @ 80%

OR

host=<hostname>.volumegroup=<volumegroup-name> Monitor and if condition persists, consider adding additional physical volumes to the volume group.

Entity Instance

host=<hostname>.filesystem=<mount-dir>

OR

host=<hostname>.volumegroup=<volumegroup-name>

Degrade Affecting Severity: Critical
Severity: C*/M
Proposed Repair Action Reduce usage or resize filesystem.

Alarm ID: 100.105 <fs_name> filesystem is not added on both controllers and/or does not have the same size: <hostname>.
Entity Instance fs_name=<image-conversion>
Degrade Affecting Severity: None
Severity: C/M*

Proposed Repair Action

Add image-conversion filesystem on both controllers.

Consult the System Administration Manual for more details.

If problem persists, contact next level of support.


Alarm ID: 100.106 'OAM' Port failed.
Entity Instance host=<hostname>.port=<port-name>
Degrade Affecting Severity: Major
Severity: M*
Proposed Repair Action Check cabling and far-end port configuration and status on adjacent equipment.

Alarm ID: 100.107

'OAM' Interface degraded.

or

'OAM' Interface failed.

Entity Instance host=<hostname>.interface=<if-name>
Degrade Affecting Severity: Major
Severity: C or M*
Proposed Repair Action Check cabling and far-end port configuration and status on adjacent equipment.

Alarm ID: 100.108 'MGMT' Port failed.
Entity Instance host=<hostname>.port=<port-name>
Degrade Affecting Severity: Major
Severity: M*
Proposed Repair Action Check cabling and far-end port configuration and status on adjacent equipment.

Alarm ID: 100.109

'OAM' Interface degraded.

or

'OAM' Interface failed.

Entity Instance host=<hostname>.interface=<if-name>
Degrade Affecting Severity: Major
Severity: C or M*
Proposed Repair Action Check cabling and far-end port configuration and status on adjacent equipment.

Alarm ID: 100.110 'CLUSTER-HOST' Port failed.
Entity Instance host=<hostname>.port=<port-name>
Degrade Affecting Severity: Major
Severity: C or M*
Proposed Repair Action Check cabling and far-end port configuration and status on adjacent equipment.

Alarm ID: 100.111

'CLUSTER-HOST' Interface degraded.

OR

'CLUSTER-HOST' Interface failed.

Entity Instance host=<hostname>.interface=<if-name>
Degrade Affecting Severity: Major
Severity: C or M*
Proposed Repair Action Check cabling and far-end port configuration and status on adjacent equipment.

Alarm ID: 100.112 'DATA-VRS' Port down.
Entity Instance host=<hostname>.port=<port-name>
Degrade Affecting Severity: Major
Severity: M
Proposed Repair Action Check cabling and far-end port configuration and status on adjacent equipment.

Alarm ID: 100.113

'DATA-VRS' Interface degraded.

or

'DATA-VRS' Interface down.

Entity Instance host=<hostname>.interface=<if-name>
Degrade Affecting Severity: Major
Severity: C or M*
Proposed Repair Action Check cabling and far-end port configuration and status on adjacent equipment.

Alarm ID: 100.114

NTP configuration does not contain any valid or reachable NTP servers. The alarm is raised regardless of NTP enabled/disabled status.

NTP address <IP address> is not a valid or a reachable NTP server.

Connectivity to external PTP Clock Synchronization is lost.

Entity Instance

host=<hostname>.ntp

host=<hostname>.ntp=<IP address>

Degrade Affecting Severity: None
Severity: M or m
Proposed Repair Action Monitor and if condition persists, contact next level of support.

Alarm ID: 100.118 Controller cannot establish connection with remote logging server.
Entity Instance host=<hostname>
Degrade Affecting Severity: None
Severity: m
Proposed Repair Action Ensure Remote Log Server IP is reachable from Controller through OAM interface; otherwise contact next level of support.

Alarm ID: 100.119

Major: PTP configuration or out-of-tolerance time-stamping conditions.

Minor: PTP out-of-tolerance time-stamping condition.

Entity Instance

host=<hostname>.ptp OR host=<hostname>.ptp=no-lock

OR

host=<hostname>.ptp=<interface>.unsupported=hardware-timestamping

OR

host=<hostname>.ptp=<interface>.unsupported=software-timestamping

OR

host=<hostname>.ptp=<interface>.unsupported=legacy-timestamping

OR

host=<hostname>.ptp=out-of-tolerance

Degrade Affecting Severity: None
Severity: M or m
Proposed Repair Action Monitor and, if condition persists, contact next level of support.