 cbc821d750
			
		
	
	cbc821d750
	
	
	
		
			
			Change-Id: I703a61da792e59fdd19dfcaef5376b7f2f2ca975 Signed-off-by: Keane Lim <keane.lim@windriver.com>
		
			
				
	
	
		
			45 lines
		
	
	
		
			1.7 KiB
		
	
	
	
		
			ReStructuredText
		
	
	
	
	
	
			
		
		
	
	
			45 lines
		
	
	
		
			1.7 KiB
		
	
	
	
		
			ReStructuredText
		
	
	
	
	
	
| 
 | |
| .. xps1552678558589
 | |
| .. _replace-osds-and-journal-disks:
 | |
| 
 | |
| ==============================
 | |
| Replace OSDs and Journal Disks
 | |
| ==============================
 | |
| 
 | |
| You can replace failed storage devices on storage nodes.
 | |
| 
 | |
| .. rubric:: |context|
 | |
| 
 | |
| For best results, ensure the replacement disk is the same size as others in
 | |
| the same peer group. Do not substitute a smaller disk than the original.
 | |
| 
 | |
| .. note::
 | |
|     Due to a limitation in **udev**, the device path of a disk connected through
 | |
|     a SAS controller changes when the disk is replaced. Therefore, in the
 | |
|     general procedure below, you must lock, delete, and re-install the node.
 | |
|     However, for standard, |AIO-SX|, and |AIO-DX| systems, use the following
 | |
|     alternative procedures to replace |OSDs| without reinstalling the host:
 | |
| 
 | |
|     -   :ref:`Replace OSDs on a Standard System
 | |
|         <replace-osds-on-a-standard-system-f3b1e376304c>`
 | |
| 
 | |
|     -   :ref:`Replace OSDs on an AIO-DX System
 | |
|         <replace-osds-on-an-aio-dx-system-319b0bc2f7e6>`
 | |
| 
 | |
|     -   :ref:`Replace OSDs on an AIO-SX Multi-Disk System
 | |
|         <replace-osds-on-an-aio-sx-multi-disk-system-b4ddd1c1257c>`
 | |
| 
 | |
|     -   :ref:`Replace ODSs on an AIO-SX Single Disk System without Backup
 | |
|         <replace-osds-on-an-aio-sx-single-disk-system-without-backup-951eefebd1f2>`
 | |
| 
 | |
|     -   :ref:`Replace OSDs on an AIO-SX Single Disk System with Backup
 | |
|         <replace-osds-on-an-aio-sx-single-disk-system-with-backup-770c9324f372>`
 | |
| 
 | |
| .. rubric:: |proc|
 | |
| 
 | |
| Follow the procedure located at |node-doc|: :ref:`Change
 | |
| Hardware Components for a Storage Host <changing-hardware-components-for-a-storage-host>`.
 | |
| 
 | |
| The replacement disk is automatically formatted and updated with data when the
 | |
| storage host is unlocked.
 |