			Updates/additions to: -System Config PTP section -Guest Integration -Admin Tasks -Updates and Upgrades Additional examples for T-BC Incorporated patchset 3 review comments. Added Limitations section. Integrated patchset 5 comments. Remove PTP Instance Removal - moved to RNs. *Do not pick 100.019 alarm update to r6 Story: 2009130 Signed-off-by: Ron Stone <ronald.stone@windriver.com> Change-Id: Ibdf449fe1d7282302d9be6d90e1c1b6dd70456b4
		
			
				
	
	
		
			61 lines
		
	
	
		
			1.5 KiB
		
	
	
	
		
			ReStructuredText
		
	
	
	
	
	
			
		
		
	
	
			61 lines
		
	
	
		
			1.5 KiB
		
	
	
	
		
			ReStructuredText
		
	
	
	
	
	
| 
 | ||
| .. bdx1614099833159
 | ||
| .. _override-default-application-values:
 | ||
| 
 | ||
| ===================================
 | ||
| Override Default Application Values
 | ||
| ===================================
 | ||
| 
 | ||
| You can override default application values using the commands described in this section.
 | ||
| 
 | ||
| 
 | ||
| 
 | ||
| .. rubric:: |proc|
 | ||
| 
 | ||
| 
 | ||
| #.  View existing values.
 | ||
| 
 | ||
|     .. code-block:: none
 | ||
| 
 | ||
|         ~(keystone_admin)]$ system helm-override-show ptp-notification
 | ||
|         ptp-notification notification
 | ||
| 
 | ||
| #.  Create a yaml file and update the fields that require Helm overrides.
 | ||
| 
 | ||
|     .. code-block:: none
 | ||
| 
 | ||
|         cat ~/override.yaml
 | ||
|         ptptracking:
 | ||
|          device:
 | ||
|            holdover_seconds: 25
 | ||
|            poll_freq_seconds: 2
 | ||
| 
 | ||
| #.  Apply the values.
 | ||
| 
 | ||
|     Application values can be added by the user and applied, using the following commands.
 | ||
| 
 | ||
|     .. note::
 | ||
|         The application could be in the "uploaded" or "applied" state.
 | ||
| 
 | ||
|     .. code-block:: none
 | ||
| 
 | ||
|         ~(keystone_admin)]$ system helm-override-update ptp-notification ptp-notification notification -–values <override.yaml>
 | ||
| 
 | ||
|     .. code-block:: none
 | ||
| 
 | ||
|         ~(keystone_admin)]$ system application-apply ptp-notification
 | ||
| 
 | ||
|     where the values are:
 | ||
| 
 | ||
|     **simulated**
 | ||
|         value must be 'false' for a normal operation \(used only for troubleshooting\).
 | ||
| 
 | ||
|     **holdover_seconds**
 | ||
|         value is the holdover time provided by the |NIC| specification. The default is 15 seconds.
 | ||
| 
 | ||
|     **poll_freq_seconds**
 | ||
|         is the frequency that the tracking function monitors the ``ptp4l`` to
 | ||
|         derive the |PTP| sync state. The default is 2 seconds.
 | ||
| 
 | ||
| 
 |