.. oim1582827207220
 | 
						|
.. _configure-the-internal-ceph-storage-backend:
 | 
						|
 | 
						|
===========================================
 | 
						|
Configure the Internal Ceph Storage Backend
 | 
						|
===========================================
 | 
						|
 | 
						|
This section provides steps to configure the internal Ceph storage backend.
 | 
						|
Depending on the system type, |prod| can be configured with an internal
 | 
						|
Ceph storage backend on controller nodes or on dedicated storage nodes.
 | 
						|
 | 
						|
.. rubric:: |prereq|
 | 
						|
 | 
						|
Unlock all controllers before you run the following commands to configure
 | 
						|
the internal Ceph storage backend.
 | 
						|
 | 
						|
.. rubric:: |proc|
 | 
						|
 | 
						|
 | 
						|
.. _configuring-the-internal-ceph-storage-backend-steps-xdm-tmz-vkb:
 | 
						|
 | 
						|
#.  Run the following command:
 | 
						|
 | 
						|
    .. code-block:: none
 | 
						|
 | 
						|
        ~(keystone_admin)$ system storage-backend-add ceph --confirmed
 | 
						|
 | 
						|
    .. note::
 | 
						|
        The default network used to deploy Ceph services on is the management
 | 
						|
        network and this should be sufficient for most systems. The
 | 
						|
        cluster-host network should only be considered for systems that are
 | 
						|
        using a 1Gb management |NIC|.
 | 
						|
 | 
						|
        For cluster-host network, use the following command:
 | 
						|
 | 
						|
        .. code-block:: none
 | 
						|
 | 
						|
            ~(keystone_admin)]$ system storage-backend-add --network cluster-host ceph --confirmed
 | 
						|
 | 
						|
#.  Wait for Ceph storage to be configured. Run the following command to
 | 
						|
    check if Ceph storage is configured:
 | 
						|
 | 
						|
    .. code-block:: none
 | 
						|
 | 
						|
        ~(keystone_admin)$ system storage-backend-list
 | 
						|
 | 
						|
#.  On a Standard configuration with Controller Storage, that is, where
 | 
						|
    Ceph |OSDs| are to be configured on the controller nodes, configure the
 | 
						|
    third Ceph monitor instance on a worker node, using the following
 | 
						|
    command:
 | 
						|
 | 
						|
    .. code-block:: none
 | 
						|
 | 
						|
        ~(keystone_admin)$ system ceph-mon-add <worker_node>
 | 
						|
 | 
						|
    .. note::
 | 
						|
        For Standard configuration with dedicated Storage, that is, where
 | 
						|
        Ceph |OSDs| are to be configured on dedicated Storage nodes, the
 | 
						|
        third Ceph monitor instance is configured by default on the first
 | 
						|
        storage node.
 | 
						|
 | 
						|
    .. note::
 | 
						|
        CephFS support requires Metadata servers \(MDS\) to be deployed. When
 | 
						|
        CephFS is configured, an MDS is deployed automatically along with each
 | 
						|
        node that has been configured to run a Ceph Monitor.
 | 
						|
 | 
						|
#.  Configure Ceph |OSDs|. For more information, see :ref:`Provision
 | 
						|
    Storage on a Controller or Storage Host Using Horizon
 | 
						|
    <provision-storage-on-a-controller-or-storage-host-using-horizon>`.
 | 
						|
 | 
						|
 |