300 Series Alarm Messages
|
|
=========================
|
|
|
|
The system inventory and maintenance service reports system changes with
|
|
different degrees of severity. Use the reported alarms to monitor the
|
|
overall health of the system.
|
|
|
|
.. include:: /_includes/x00-series-alarm-messages.rest
|
|
|
|
.. _300-series-alarm-messages-table-zrd-tg5-v5:
|
|
|
|
.. list-table::
|
|
:widths: 6 25
|
|
:header-rows: 0
|
|
|
|
* - **Alarm ID: 300.001**
|
|
- 'Data' Port failed.
|
|
* - Entity Instance
|
|
- host=<hostname>.port=<port-uuid>
|
|
* - Degrade Affecting Severity:
|
|
- None
|
|
* - Severity:
|
|
- M\*
|
|
* - Proposed Repair Action
|
|
- Check cabling and far-end port configuration and status on adjacent
|
|
equipment.
|
|
|
|
-----
|
|
|
|
.. list-table::
|
|
:widths: 6 25
|
|
:header-rows: 0
|
|
|
|
* - **Alarm ID: 300.002**
|
|
- 'Data' Interface degraded.
|
|
|
|
or
|
|
|
|
'Data' Interface failed.
|
|
* - Entity Instance
|
|
- host=<hostname>.interface=<if-uuid>
|
|
* - Degrade Affecting Severity:
|
|
- Critical
|
|
* - Severity:
|
|
- C/M\*
|
|
* - Proposed Repair Action
|
|
- Check cabling and far-end port configuration and status on adjacent
|
|
equipment. |