Ceilometer Redis plugin
=======================
Ceilometer Redis Plugin aims to install Redis to MOS environment and provide a coordination mechanism for
`Ceilometer agents <https://ceilometer.readthedocs.org/en/latest/architecture.html>`_ and Alarm Evaluator
through the `tooz library <http://docs.openstack.org/developer/tooz/>`_ with a `Redis backend <http://redis.io>`_
The plugin supports coordination for the following Ceilometer services: central agent, notification agent
and alarm-evaluator. Each of these services are running on every controller after the plugin
is installed. All of them are joined into the corresponding coordination group (one coordination group
per each service). It differs from the default configuration when there should be only one central agent
and alarm-evaluator per cloud. The plugin also configures redis-server under pacemaker to monitor its process.
The plugin configures `redis-sentinel <http://redis.io/topics/sentinel>`_ to monitor the state of the redis
cluster, to elect new master during failovers, to forward ceilometer services to new elected redis master,
to organize sync between redis nodes.
Central agent
-------------
Ceilometer Central agent is responsible for polling all OpenStack resources except Nova's (Nova resources,
i.e. vms, are polled by a Compute agent). Without coordination enabled, only one Central agent should be running
per cloud. The reason is that all the central agents have the same set of OpenStack resources to poll every
configurable time interval. If coordination is not enabled, each OpenStack resource will be polled as many times
as many instances of Central agents are running in a cloud.
Thus, coordination provides a disjoint set of OpenStack resources to poll for every Central agent running on the
cloud to avoid polling one resource several times.
Alarm evaluator
---------------
Ceilometer alarm evaluator service is responsible for Ceilometer alarm evaluation.
By default, in MOS there is only one alarm evaluator per cloud. The reason is the same as for a central agent.
If there are several alarm evaluators and no coordination enabled, all of them will evaluate the same set of alarms
every configurable time interval. The alarm sets for evaluators should be disjoint. So, coordination is responsible
for providing the set of alarms to evaluate to each alarm-evaluator in the cloud.
Notification agent
------------------
Before Liberty, there was no need to coordinate Ceilometer notification agents. But starting from Liberty, samples
transformations started to be handled not by compute/central agents as it was before, but by a notification agent.
Some of Ceilometer transformers have a local cache where it is stored the data from previously processed samples.
For example, "cpu_util" metric are obtained from two consecutive Samples with "cpu" metric: one is subtracted from
another and divided to an amount of cpu (this information is stored in Sample's metadata).
Thus, it should be guaranteed that all the Samples which should be transformed by one transformer, will go to the
same notification agent. If some of the samples go to another, the cache cannot be shared and some data will be lost.
To handle this process properly, IPC queues was introduced - inter process communication queues in message bus
(RabbitMQ). With coordination enabled, each notification agent has two set of listeners: for main queues and for IPC
queues. All notification agents listen to _all_ the main queues (where we have all messages from OpenStack services
and polling-based messages from central/compute agents) and re-publish messages to _all_ IPC queues. Coordination
starts to work at this point: every notification agent in the cloud has it's own set of IPC queues to listen to. Thus,
we can be sure that local cache on each notification agent contains all the previous data required for transformation.
Requirements
------------
======================= ================
Requirement Version/Comment
======================= ================
Fuel 7.0, 8.0
tooz <0.14.0,>=0.13.1
======================= ================
.. _limitations:
Limitations
-----------
* The plugin works correctly only on clouds with odd numbers of controllers.
This requirement is mandatory because Redis needs an odd number of nodes to
choose the master successfully.
* In MOS 8.0, there are no transformers configured by default. The plugin doesn't add any of them into
ceilometer's pipeline.yaml. Thus, you need to configure it manually if you want to use transformers.
If you don't need this feature, it is recommended to disable coordination for the notification agents.
.. include:: installation.rst
.. include:: guide.rst