Files
whoami-rajat 1a8ea0eac4 Skip sparse copy during volume reimage
When rebuilding a volume backed instance, while copying the new
image to the existing volume, we preserve sparseness.
This could be problematic since we don't write the zero blocks of
the new image and the data in the old image can still persist
leading to a data leak scenario.

To prevent this, we are using `-S 0`[1][2] option with the `qemu-img convert`
command to write all the zero bytes into the volume.

In the testing done, this doesn't seem to be a problem with known 'raw'
images but good to handle the case anyway.

Following is the testing performed with 3 images:

1. CIRROS QCOW2 to RAW
======================

Volume size: 1 GiB
Image size (raw): 112 MiB

CREATE VOLUME FROM IMAGE (without -S 0)

LVS (10.94% allocated)
  volume-91ea43ef-684c-402f-896e-63e45e5f4fff stack-volumes-lvmdriver-1 Vwi-a-tz-- 1.00g stack-volumes-lvmdriver-1-pool 10.94

REBUILD (with -S 0)

LVS (10.94% allocated)
  volume-91ea43ef-684c-402f-896e-63e45e5f4fff stack-volumes-lvmdriver-1 Vwi-aotz-- 1.00g stack-volumes-lvmdriver-1-pool 10.94

Conclusion:
Same space is consumed on the disk with and without preserving sparseness.

2. DEBIAN QCOW2 to RAW
======================

Volume size: 3 GiB
Image size (raw): 2 GiB

CREATE VOLUME FROM IMAGE (without -S 0)

LVS (66.67% allocated)
  volume-edc42b6a-df5d-420e-85d3-b3e52bcb735e stack-volumes-lvmdriver-1 Vwi-a-tz-- 3.00g stack-volumes-lvmdriver-1-pool 66.67

REBUILD (with -S 0)

LVS (66.67% allocated)
  volume-edc42b6a-df5d-420e-85d3-b3e52bcb735e stack-volumes-lvmdriver-1 Vwi-aotz-- 3.00g stack-volumes-lvmdriver-1-pool 66.67

Conclusion:
Same space is consumed on the disk with and without preserving sparseness.

3. FEDORA QCOW2 TO RAW
======================

CREATE VOLUME FROM IMAGE (without -S 0)

Volume size: 6 GiB
Image size (raw): 5 GiB

LVS (83.33% allocated)
  volume-efa1a227-a30d-4385-867a-db22a3e80ad7 stack-volumes-lvmdriver-1 Vwi-a-tz-- 6.00g stack-volumes-lvmdriver-1-pool 83.33

REBUILD (with -S 0)

LVS (83.33% allocated)
  volume-efa1a227-a30d-4385-867a-db22a3e80ad7 stack-volumes-lvmdriver-1 Vwi-aotz-- 6.00g stack-volumes-lvmdriver-1-pool 83.33

Conclusion:
Same space is consumed on the disk with and without preserving sparseness.

Another testing was done to check if the `-S 0` option actually
works in OpenStack setup.
Note that we are converting qcow2 to qcow2 image which won't
happen in a real world deployment and only for test purposes.

DEBIAN QCOW2 TO QCOW2
=====================

CREATE VOLUME FROM IMAGE (without -S 0)

LVS (52.61% allocated)
  volume-de581f84-e722-4f4a-94fb-10f767069f50 stack-volumes-lvmdriver-1 Vwi-a-tz-- 3.00g stack-volumes-lvmdriver-1-pool 52.61

REBUILD (with -S 0)

LVS (66.68% allocated)
  volume-de581f84-e722-4f4a-94fb-10f767069f50 stack-volumes-lvmdriver-1 Vwi-aotz-- 3.00g stack-volumes-lvmdriver-1-pool 66.68

Conclusion:
We can see that the space allocation increased hence we are not preserving sparseness when using the -S 0 option.

[1] https://qemu-project.gitlab.io/qemu/tools/qemu-img.html#cmdoption-qemu-img-common-opts-S
[2] abf635ddfe/qemu-img.c (L182-L186)

Closes-Bug: #2045431

Change-Id: I5be7eaba68a5b8e1c43f0d95486b5c79c14e1b95
2023-12-26 13:08:58 +05:30

407 lines
16 KiB
Python

# Copyright (c) 2017 VMware, Inc.
# All Rights Reserved.
#
# Licensed under the Apache License, Version 2.0 (the "License"); you may
# not use this file except in compliance with the License. You may obtain
# a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
# License for the specific language governing permissions and limitations
# under the License.
"""
VMware VStorageObject driver
Volume driver based on VMware VStorageObject aka First Class Disk (FCD). This
driver requires a minimum vCenter version of 6.5.
"""
from oslo_log import log as logging
from oslo_utils import units
from oslo_utils import versionutils
from oslo_vmware import image_transfer
from oslo_vmware.objects import datastore
from oslo_vmware import vim_util
from cinder.common import constants
from cinder import exception
from cinder.i18n import _
from cinder import interface
from cinder.volume.drivers.vmware import datastore as hub
from cinder.volume.drivers.vmware import vmdk
from cinder.volume.drivers.vmware import volumeops as vops
from cinder.volume import volume_utils
LOG = logging.getLogger(__name__)
@interface.volumedriver
class VMwareVStorageObjectDriver(vmdk.VMwareVcVmdkDriver):
"""Volume driver based on VMware VStorageObject"""
# 1.0 - initial version based on vSphere 6.5 vStorageObject APIs
# 1.1 - support for vStorageObject snapshot APIs
# 1.2 - support for SPBM storage policies
# 1.3 - support for retype
VERSION = '1.3.0'
# ThirdPartySystems wiki page
CI_WIKI_NAME = "VMware_CI"
# minimum supported vCenter version
MIN_SUPPORTED_VC_VERSION = '6.5'
STORAGE_TYPE = constants.VSTORAGE
def do_setup(self, context):
"""Any initialization the volume driver needs to do while starting.
:param context: The admin context.
"""
super(VMwareVStorageObjectDriver, self).do_setup(context)
self.volumeops.set_vmx_version('vmx-13')
vc_67_compatible = versionutils.is_compatible(
'6.7.0', self._vc_version, same_major=False)
self._use_fcd_snapshot = vc_67_compatible
self._storage_policy_enabled = vc_67_compatible
def get_volume_stats(self, refresh=False):
"""Collects volume backend stats.
:param refresh: Whether to discard any cached values and force a full
refresh of stats.
:returns: dict of appropriate values.
"""
stats = super(VMwareVStorageObjectDriver, self).get_volume_stats(
refresh=refresh)
stats['storage_protocol'] = self.STORAGE_TYPE
return stats
def _select_ds_fcd(self, volume):
req = {}
req[hub.DatastoreSelector.SIZE_BYTES] = volume.size * units.Gi
if self._storage_policy_enabled:
req[hub.DatastoreSelector.PROFILE_NAME] = (
self._get_storage_profile(volume))
(_host_ref, _resource_pool, summary) = self._select_datastore(req)
return summary.datastore
def _get_temp_image_folder(self, size_bytes, preallocated=False):
req = {}
req[hub.DatastoreSelector.SIZE_BYTES] = size_bytes
if preallocated:
req[hub.DatastoreSelector.HARD_AFFINITY_DS_TYPE] = (
hub.DatastoreType.get_all_types() -
{hub.DatastoreType.VSAN, hub.DatastoreType.VVOL})
(host_ref, _resource_pool, summary) = self._select_datastore(req)
folder_path = vmdk.TMP_IMAGES_DATASTORE_FOLDER_PATH
dc_ref = self.volumeops.get_dc(host_ref)
self.volumeops.create_datastore_folder(
summary.name, folder_path, dc_ref)
return (dc_ref, summary, folder_path)
def _get_disk_type(self, volume):
extra_spec_disk_type = super(
VMwareVStorageObjectDriver, self)._get_disk_type(volume)
return vops.VirtualDiskType.get_virtual_disk_type(extra_spec_disk_type)
def _get_storage_profile_id(self, volume):
if self._storage_policy_enabled:
return super(
VMwareVStorageObjectDriver, self)._get_storage_profile_id(
volume)
def create_volume(self, volume):
"""Create a new volume on the backend.
:param volume: Volume object containing specifics to create.
:returns: (Optional) dict of database updates for the new volume.
"""
disk_type = self._get_disk_type(volume)
ds_ref = self._select_ds_fcd(volume)
profile_id = self._get_storage_profile_id(volume)
fcd_loc = self.volumeops.create_fcd(
volume.name, volume.size * units.Ki, ds_ref, disk_type,
profile_id=profile_id)
return {'provider_location': fcd_loc.provider_location()}
def _delete_fcd(self, provider_loc):
fcd_loc = vops.FcdLocation.from_provider_location(provider_loc)
self.volumeops.delete_fcd(fcd_loc)
def delete_volume(self, volume):
"""Delete a volume from the backend.
:param volume: The volume to delete.
"""
if not volume.provider_location:
LOG.warning("FCD provider location is empty for volume %s",
volume.id)
else:
self._delete_fcd(volume.provider_location)
def initialize_connection(self, volume, connector, initiator_data=None):
"""Allow connection to connector and return connection info.
:param volume: The volume to be attached.
:param connector: Dictionary containing information about what is being
connected to.
:param initiator_data: (Optional) A dictionary of driver_initiator_data
objects with key-value pairs that have been
saved for this initiator by a driver in previous
initialize_connection calls.
:returns: A dictionary of connection information.
"""
fcd_loc = vops.FcdLocation.from_provider_location(
volume.provider_location)
connection_info = {'driver_volume_type': self.STORAGE_TYPE}
connection_info['data'] = {
'id': fcd_loc.fcd_id,
'ds_ref_val': fcd_loc.ds_ref_val,
'adapter_type': self._get_adapter_type(volume)
}
LOG.debug("Connection info for volume %(name)s: %(connection_info)s.",
{'name': volume.name, 'connection_info': connection_info})
return connection_info
def _validate_container_format(self, container_format, image_id):
if container_format and container_format != 'bare':
msg = _("Container format: %s is unsupported, only 'bare' "
"is supported.") % container_format
LOG.error(msg)
raise exception.ImageUnacceptable(image_id=image_id, reason=msg)
def copy_image_to_volume(self, context, volume, image_service, image_id,
disable_sparse=False):
"""Fetch the image from image_service and write it to the volume.
:param context: Security/policy info for the request.
:param volume: The volume to create.
:param image_service: The image service to use.
:param image_id: The image identifier.
:param disable_sparse: Enable or disable sparse copy. Default=False.
This parameter is ignored by VMware driver.
:returns: Model updates.
"""
metadata = image_service.show(context, image_id)
self._validate_disk_format(metadata['disk_format'])
self._validate_container_format(
metadata.get('container_format'), image_id)
properties = metadata['properties'] or {}
disk_type = properties.get('vmware_disktype',
vmdk.ImageDiskType.PREALLOCATED)
vmdk.ImageDiskType.validate(disk_type)
size_bytes = metadata['size']
dc_ref, summary, folder_path = self._get_temp_image_folder(
volume.size * units.Gi)
disk_name = volume.id
if disk_type in [vmdk.ImageDiskType.SPARSE,
vmdk.ImageDiskType.STREAM_OPTIMIZED]:
vmdk_path = self._create_virtual_disk_from_sparse_image(
context, image_service, image_id, size_bytes, dc_ref,
summary.name, folder_path, disk_name)
else:
vmdk_path = self._create_virtual_disk_from_preallocated_image(
context, image_service, image_id, size_bytes, dc_ref,
summary.name, folder_path, disk_name,
vops.VirtualDiskAdapterType.LSI_LOGIC)
ds_path = datastore.DatastorePath.parse(
vmdk_path.get_descriptor_ds_file_path())
dc_path = self.volumeops.get_inventory_path(dc_ref)
vmdk_url = datastore.DatastoreURL(
'https', self.configuration.vmware_host_ip, ds_path.rel_path,
dc_path, ds_path.datastore)
fcd_loc = self.volumeops.register_disk(
str(vmdk_url), volume.name, summary.datastore)
profile_id = self._get_storage_profile_id(volume)
if profile_id:
self.volumeops.update_fcd_policy(fcd_loc, profile_id)
return {'provider_location': fcd_loc.provider_location()}
def copy_volume_to_image(self, context, volume, image_service, image_meta):
"""Copy the volume to the specified image.
:param context: Security/policy info for the request.
:param volume: The volume to copy.
:param image_service: The image service to use.
:param image_meta: Information about the image.
:returns: Model updates.
"""
self._validate_disk_format(image_meta['disk_format'])
fcd_loc = vops.FcdLocation.from_provider_location(
volume.provider_location)
hosts = self.volumeops.get_connected_hosts(fcd_loc.ds_ref())
host = vim_util.get_moref(hosts[0], 'HostSystem')
LOG.debug("Selected host: %(host)s for downloading fcd: %(fcd_loc)s.",
{'host': host, 'fcd_loc': fcd_loc})
attached = False
try:
create_params = {vmdk.CREATE_PARAM_DISK_LESS: True}
backing = self._create_backing(volume, host, create_params)
self.volumeops.attach_fcd(backing, fcd_loc)
attached = True
vmdk_file_path = self.volumeops.get_vmdk_path(backing)
conf = self.configuration
# retrieve store information from extra-specs
store_id = volume.volume_type.extra_specs.get(
'image_service:store_id')
# TODO (whoami-rajat): Remove store_id and base_image_ref
# parameters when oslo.vmware calls volume_utils wrapper of
# upload_volume instead of image_utils.upload_volume
image_transfer.upload_image(
context,
conf.vmware_image_transfer_timeout_secs,
image_service,
image_meta['id'],
volume.project_id,
session=self.session,
host=conf.vmware_host_ip,
port=conf.vmware_host_port,
vm=backing,
vmdk_file_path=vmdk_file_path,
vmdk_size=volume.size * units.Gi,
image_name=image_meta['name'],
store_id=store_id,
base_image_ref=volume_utils.get_base_image_ref(volume))
finally:
if attached:
self.volumeops.detach_fcd(backing, fcd_loc)
backing = self.volumeops.get_backing_by_uuid(volume.id)
if backing:
self._delete_temp_backing(backing)
def extend_volume(self, volume, new_size):
"""Extend the size of a volume.
:param volume: The volume to extend.
:param new_size: The new desired size of the volume.
"""
fcd_loc = vops.FcdLocation.from_provider_location(
volume.provider_location)
self.volumeops.extend_fcd(fcd_loc, new_size * units.Ki)
def _clone_fcd(self, provider_loc, name, dest_ds_ref,
disk_type=vops.VirtualDiskType.THIN,
profile_id=None):
fcd_loc = vops.FcdLocation.from_provider_location(provider_loc)
return self.volumeops.clone_fcd(
name, fcd_loc, dest_ds_ref, disk_type, profile_id=profile_id)
def create_snapshot(self, snapshot):
"""Creates a snapshot.
:param snapshot: Information for the snapshot to be created.
"""
if self._use_fcd_snapshot:
fcd_loc = vops.FcdLocation.from_provider_location(
snapshot.volume.provider_location)
description = "snapshot-%s" % snapshot.id
fcd_snap_loc = self.volumeops.create_fcd_snapshot(
fcd_loc, description=description)
return {'provider_location': fcd_snap_loc.provider_location()}
ds_ref = self._select_ds_fcd(snapshot.volume)
cloned_fcd_loc = self._clone_fcd(
snapshot.volume.provider_location, snapshot.name, ds_ref)
return {'provider_location': cloned_fcd_loc.provider_location()}
def delete_snapshot(self, snapshot):
"""Deletes a snapshot.
:param snapshot: The snapshot to delete.
"""
if not snapshot.provider_location:
LOG.debug("FCD snapshot location is empty.")
return
fcd_snap_loc = vops.FcdSnapshotLocation.from_provider_location(
snapshot.provider_location)
if fcd_snap_loc:
self.volumeops.delete_fcd_snapshot(fcd_snap_loc)
else:
self._delete_fcd(snapshot.provider_location)
def _extend_if_needed(self, fcd_loc, cur_size, new_size):
if new_size > cur_size:
self.volumeops.extend_fcd(fcd_loc, new_size * units.Ki)
def _create_volume_from_fcd(self, provider_loc, cur_size, volume):
ds_ref = self._select_ds_fcd(volume)
disk_type = self._get_disk_type(volume)
profile_id = self._get_storage_profile_id(volume)
cloned_fcd_loc = self._clone_fcd(
provider_loc, volume.name, ds_ref, disk_type=disk_type,
profile_id=profile_id)
self._extend_if_needed(cloned_fcd_loc, cur_size, volume.size)
return {'provider_location': cloned_fcd_loc.provider_location()}
def create_volume_from_snapshot(self, volume, snapshot):
"""Creates a volume from a snapshot.
:param volume: The volume to be created.
:param snapshot: The snapshot from which to create the volume.
:returns: A dict of database updates for the new volume.
"""
fcd_snap_loc = vops.FcdSnapshotLocation.from_provider_location(
snapshot.provider_location)
if fcd_snap_loc:
profile_id = self._get_storage_profile_id(volume)
fcd_loc = self.volumeops.create_fcd_from_snapshot(
fcd_snap_loc, volume.name, profile_id=profile_id)
self._extend_if_needed(fcd_loc, snapshot.volume_size, volume.size)
return {'provider_location': fcd_loc.provider_location()}
else:
return self._create_volume_from_fcd(snapshot.provider_location,
snapshot.volume.size, volume)
def create_cloned_volume(self, volume, src_vref):
"""Creates a clone of the specified volume.
:param volume: New Volume object
:param src_vref: Source Volume object
"""
return self._create_volume_from_fcd(
src_vref.provider_location, src_vref.size, volume)
def retype(self, context, volume, new_type, diff, host):
if not self._storage_policy_enabled:
return True
profile = self._get_storage_profile(volume)
new_profile = self._get_extra_spec_storage_profile(new_type['id'])
if profile == new_profile:
LOG.debug("Storage profile matches between new type and old type.")
return True
if self._in_use(volume):
LOG.warning("Cannot change storage profile of attached FCD.")
return False
fcd_loc = vops.FcdLocation.from_provider_location(
volume.provider_location)
new_profile_id = self.ds_sel.get_profile_id(new_profile)
self.volumeops.update_fcd_policy(fcd_loc, new_profile_id.uniqueId)