Dell EMC PowerMax iSCSI and FC drivers
|
||
======================================
|
||
|
||
The Dell EMC PowerMax drivers, ``PowerMaxISCSIDriver`` and
|
||
``PowerMaxFCDriver``, support the use of Dell EMC PowerMax and VMAX storage
|
||
arrays with the Cinder Block Storage project. They both provide equivalent
|
||
functions and differ only in support for their respective host attachment
|
||
methods.
|
||
|
||
The drivers perform volume operations by communicating with the back-end
|
||
PowerMax storage management software. They use the Requests HTTP library to
|
||
communicate with a Unisphere for PowerMax instance, using a RESTAPI interface
|
||
in the backend to perform PowerMax and VMAX storage operations.
|
||
|
||
.. _VMAX-Hybrid:
|
||
|
||
.. note::
|
||
|
||
DEPRECATION NOTICE: The VMAX Hybrid series will not be supported from the
|
||
``Z`` release of OpenStack. Also, any All Flash array
|
||
running HyperMaxOS 5977 will no longer be supported from the ``Z``
|
||
release onwards.
|
||
|
||
|
||
.. note::
|
||
|
||
While ``PowerMax`` will be used throughout this document, it will be used
|
||
to collectively categorize the following supported arrays, PowerMax 2000,
|
||
8000, VMAX All Flash 250F, 450F, 850F and 950F and VMAX-Hybrid_.
|
||
|
||
|
||
System requirements and licensing
|
||
=================================
|
||
|
||
The Dell EMC PowerMax Cinder driver supports the VMAX-Hybrid_ series,
|
||
VMAX All-Flash series and the PowerMax arrays.
|
||
|
||
The array operating system software, Solutions Enabler 9.2.2 series, and
|
||
Unisphere for PowerMax 9.2.2 series are required to run Dell EMC PowerMax
|
||
Cinder driver for the Wallaby release. Please refer to support-matrix-table_
|
||
for the support matrix of previous OpenStack versions.
|
||
|
||
Download Solutions Enabler and Unisphere from the Dell EMC's support web site
|
||
(login is required). See the `Dell EMC Solutions Enabler 9.2.2 Installation
|
||
and Configuration Guide` and `Dell EMC Unisphere for PowerMax Installation
|
||
Guide` at the `Dell EMC Support`_ site.
|
||
|
||
.. note::
|
||
|
||
At the time each OpenStack release, support-matrix-table_ was the
|
||
recommended PowerMax management software and OS combinations. Please
|
||
reach out your local PowerMax representative to see if these versions
|
||
are still valid.
|
||
|
||
|
||
.. _support-matrix-table:
|
||
|
||
.. table:: PowerMax Management software and OS for OpenStack release
|
||
|
||
+-----------+------------------------+-------------+
|
||
| OpenStack | Unisphere for PowerMax | PowerMax OS |
|
||
+===========+========================+=============+
|
||
| Xena | 9.2.2 | 5978.711 |
|
||
+-----------+------------------------+-------------+
|
||
| Wallaby | 9.2.1 | 5978.711 |
|
||
+-----------+------------------------+-------------+
|
||
| Victoria | 9.2.x | 5978.669 |
|
||
+-----------+------------------------+-------------+
|
||
| Ussuri | 9.1.x | 5978.479 |
|
||
+-----------+------------------------+-------------+
|
||
| Train | 9.1.x | 5978.444 |
|
||
+-----------+------------------------+-------------+
|
||
| Stein | 9.0.x | 5978.221 |
|
||
+-----------+------------------------+-------------+
|
||
|
||
.. note::
|
||
|
||
A Hybrid array can only run HyperMax OS 5977, and is still supported until
|
||
the ``Z`` release of OpenStack. Some functionality will not be available
|
||
in older versions of the OS. If in any doubt, please contact your local
|
||
PowerMax representative.
|
||
|
||
.. note::
|
||
|
||
Newer versions of Unisphere for PowerMax and PowerMax OS are not
|
||
retrospectively tested on older versions of OpenStack. If it is necessary
|
||
to upgrade, the older REST endpoints will be used. For example, in Ussuri,
|
||
if upgrading to Unisphere for PowerMax 9.2, the older ``91`` endpoints will
|
||
be used.
|
||
|
||
|
||
|
||
Required PowerMax software suites for OpenStack
|
||
-----------------------------------------------
|
||
|
||
The storage system requires a Unisphere for PowerMax (SMC) eLicense.
|
||
|
||
PowerMax
|
||
~~~~~~~~
|
||
There are two licenses for the PowerMax 2000 and 8000:
|
||
|
||
- Essentials software package
|
||
- Pro software package
|
||
|
||
The Dell EMC PowerMax cinder driver requires the Pro software package.
|
||
|
||
All Flash
|
||
~~~~~~~~~
|
||
For full functionality including SRDF for the VMAX All Flash, the FX package,
|
||
or the F package plus the SRDF a la carte add on is required.
|
||
|
||
Hybrid
|
||
~~~~~~
|
||
|
||
There are five Dell EMC Software Suites sold with the VMAX-Hybrid_ arrays:
|
||
|
||
- Base Suite
|
||
- Advanced Suite
|
||
- Local Replication Suite
|
||
- Remote Replication Suite
|
||
- Total Productivity Pack
|
||
|
||
The Dell EMC PowerMax Cinder driver requires the Advanced Suite and the Local
|
||
Replication Suite or the Total Productivity Pack (it includes the Advanced
|
||
Suite and the Local Replication Suite) for the VMAX Hybrid.
|
||
|
||
Using PowerMax Remote Replication functionality will also require the Remote
|
||
Replication Suite.
|
||
|
||
|
||
.. note::
|
||
|
||
Each are licensed separately. For further details on how to get the
|
||
relevant license(s), reference eLicensing Support below.
|
||
|
||
|
||
eLicensing support
|
||
------------------
|
||
|
||
To activate your entitlements and obtain your PowerMax license files, visit the
|
||
Service Center on `Dell EMC Support`_, as directed on your License
|
||
Authorization Code (LAC) letter emailed to you.
|
||
|
||
- For help with missing or incorrect entitlements after activation
|
||
(that is, expected functionality remains unavailable because it is not
|
||
licensed), contact your EMC account representative or authorized reseller.
|
||
|
||
- For help with any errors applying license files through Solutions Enabler,
|
||
contact the Dell EMC Customer Support Center.
|
||
|
||
- If you are missing a LAC letter or require further instructions on
|
||
activating your licenses through the Online Support site, contact EMC's
|
||
worldwide Licensing team at ``licensing@emc.com`` or call:
|
||
|
||
North America, Latin America, APJK, Australia, New Zealand: SVC4EMC
|
||
(800-782-4362) and follow the voice prompts.
|
||
|
||
EMEA: +353 (0) 21 4879862 and follow the voice prompts.
|
||
|
||
|
||
PowerMax for OpenStack Cinder customer support
|
||
----------------------------------------------
|
||
|
||
If you require help or assistance with PowerMax and Cinder please open a
|
||
Service Request (SR) through standard support channels at `Dell EMC Support`_.
|
||
When opening a SR please include the following information:
|
||
|
||
- Array Model & uCode level
|
||
- Unisphere for PowerMax version
|
||
- Solutions Enabler Version
|
||
- OpenStack host Operating System (Ubuntu, RHEL, etc.)
|
||
- OpenStack version (Usurri, Train, etc.)
|
||
- PowerMax for Cinder driver version, this can be located in the comments in
|
||
the PowerMax driver file:
|
||
``{cinder_install_dir}/cinder/volume/drivers/dell_emc/powermax/fc.py``
|
||
- Cinder logs
|
||
- Detailed description of the issue you are encountering
|
||
|
||
|
||
Supported operations
|
||
====================
|
||
|
||
PowerMax drivers support these operations:
|
||
|
||
- Create, list, delete, attach, and detach volumes
|
||
- Create, list, and delete volume snapshots
|
||
- Copy an image to a volume
|
||
- Copy a volume to an image
|
||
- Clone a volume
|
||
- Extend a volume
|
||
- Retype a volume (Host and storage assisted volume migration)
|
||
- Create a volume from a snapshot
|
||
- Create and delete generic volume group
|
||
- Create and delete generic volume group snapshot
|
||
- Modify generic volume group (add and remove volumes)
|
||
- Create generic volume group from source
|
||
- Live Migration
|
||
- Volume replication SRDF/S, SRDF/A and SRDF Metro
|
||
- Quality of service (QoS)
|
||
- Manage and unmanage volumes and snapshots
|
||
- List Manageable Volumes/Snapshots
|
||
- Backup create, delete, list, restore and show
|
||
|
||
PowerMax drivers also support the following features:
|
||
|
||
- Dynamic masking view creation
|
||
- Dynamic determination of the target iSCSI IP address
|
||
- iSCSI multipath support
|
||
- Oversubscription
|
||
- Service Level support
|
||
- SnapVX support
|
||
- Compression support(All Flash and PowerMax)
|
||
- Deduplication support(PowerMax)
|
||
- CHAP Authentication
|
||
- Multi-attach support
|
||
- Volume Metadata in logs
|
||
- Encrypted Volume support
|
||
- Extending attached volume
|
||
- Replicated volume retype support
|
||
- Retyping attached(in-use) volume
|
||
- Unisphere High Availability(HA) support
|
||
- Online device expansion of a metro device
|
||
- Rapid TDEV deallocation of deletes
|
||
- Multiple replication devices
|
||
- PowerMax array and storage group tagging
|
||
- Short host name and port group templates
|
||
- Snap id support
|
||
- Seamless Live Migration from SMI-S support
|
||
- Port group & port performance load balancing
|
||
|
||
.. note::
|
||
|
||
In certain cases, when creating a volume from a source snapshot or
|
||
source volume, subsequent operations using the volumes may fail due to
|
||
a missing snap_name exception. A manual refresh on the connected
|
||
Unisphere instance or waiting until another operation automatically
|
||
refreshes the connected Unisphere instance, will alleviate this issue.
|
||
|
||
PowerMax naming conventions
|
||
===========================
|
||
|
||
.. note::
|
||
|
||
``shortHostName`` will be altered using the following formula, if its length
|
||
exceeds 16 characters. This is because the storage group and masking view
|
||
names cannot exceed 64 characters:
|
||
|
||
.. code-block:: text
|
||
|
||
if len(shortHostName) > 16:
|
||
1. Perform md5 hash on the shortHostName
|
||
2. Convert output of 1. to hex
|
||
3. Take last 6 characters of shortHostName and append output of 2.
|
||
4. If the length of output of 3. exceeds 16 characters, join the
|
||
first 8 characters and last 8 characters.
|
||
|
||
.. note::
|
||
|
||
``portgroup_name`` will be altered using the following formula, if its
|
||
length exceeds 12 characters. This is because the storage group and masking
|
||
view names cannot exceed 64 characters:
|
||
|
||
.. code-block:: text
|
||
|
||
if len(portgroup_name) > 12:
|
||
1. Perform md5 hash on the portgroup_name
|
||
2. Convert output of 1. to hex
|
||
3. Take last 6 characters of portgroup_name and append output of 2.
|
||
4. If the length of output of 3. exceeds 12 characters, join the
|
||
first 6 characters and last 6 characters.
|
||
|
||
|
||
Masking view names
|
||
------------------
|
||
|
||
Masking views are dynamically created by the PowerMax FC and iSCSI drivers
|
||
using the following naming conventions. ``[protocol]`` is either ``I`` for
|
||
volumes attached over iSCSI or ``F`` for volumes attached over Fibre Channel.
|
||
|
||
.. code-block:: text
|
||
|
||
OS-[shortHostName]-[protocol]-[portgroup_name]-MV
|
||
|
||
Initiator group names
|
||
---------------------
|
||
|
||
For each host that is attached to PowerMax volumes using the drivers, an
|
||
initiator group is created or re-used (per attachment type). All initiators
|
||
of the appropriate type known for that host are included in the group. At
|
||
each new attach volume operation, the PowerMax driver retrieves the initiators
|
||
(either WWNNs or IQNs) from OpenStack and adds or updates the contents of the
|
||
Initiator Group as required. Names are of the following format. ``[protocol]``
|
||
is either ``I`` for volumes attached over iSCSI or ``F`` for volumes attached
|
||
over Fibre Channel.
|
||
|
||
.. code-block:: console
|
||
|
||
OS-[shortHostName]-[protocol]-IG
|
||
|
||
.. note::
|
||
|
||
Hosts attaching to OpenStack managed PowerMax storage cannot also attach to
|
||
storage on the same PowerMax that are not managed by OpenStack.
|
||
|
||
FA port groups
|
||
--------------
|
||
|
||
PowerMax array FA ports to be used in a new masking view are retrieved from the
|
||
port group provided as the extra spec on the volume type, or chosen from the
|
||
list provided in the Dell EMC configuration file.
|
||
|
||
Storage group names
|
||
-------------------
|
||
|
||
As volumes are attached to a host, they are either added to an existing
|
||
storage group (if it exists) or a new storage group is created and the volume
|
||
is then added. Storage groups contain volumes created from a pool, attached
|
||
to a single host, over a single connection type (iSCSI or FC). ``[protocol]``
|
||
is either ``I`` for volumes attached over iSCSI or ``F`` for volumes attached
|
||
over Fibre Channel. PowerMax Cinder driver utilizes cascaded storage groups -
|
||
a ``parent`` storage group which is associated with the masking view, which
|
||
contains ``child`` storage groups for each configured
|
||
SRP/slo/workload/compression-enabled or disabled/replication-enabled or
|
||
disabled combination.
|
||
|
||
PowerMax, VMAX All Flash and VMAX-Hybrid_
|
||
|
||
Parent storage group:
|
||
|
||
.. code-block:: text
|
||
|
||
OS-[shortHostName]-[protocol]-[portgroup_name]-SG
|
||
|
||
Child storage groups:
|
||
|
||
.. code-block:: text
|
||
|
||
OS-[shortHostName]-[SRP]-[ServiceLevel/Workload]-[portgroup_name]-CD-RE
|
||
|
||
.. note::
|
||
|
||
CD and RE are only set if compression is explicitly disabled or replication
|
||
explicitly enabled. See the compression `11. All Flash compression support`_
|
||
and replication `Volume replication support`_ sections below.
|
||
|
||
.. note::
|
||
|
||
For VMAX All Flash with PowerMax OS (5978) or greater, workload if set will
|
||
be ignored and set to NONE.
|
||
|
||
.. _my-table:
|
||
|
||
.. table:: Replication storage group naming conventions
|
||
|
||
+----------------------------+---------------------------------+--------------------------------+--------------------+
|
||
| Default storage group | Attached child storage group | Management Group | Replication Type |
|
||
+============================+=================================+================================+====================+
|
||
| OS-[SRP]-[SL]-[WL]-SG | OS-[HOST]-[SRP]-[SL/WL]-[PG] | N/A | None |
|
||
+----------------------------+---------------------------------+--------------------------------+--------------------+
|
||
| OS-[SRP]-[SL]-[WL]-RE-SG | OS-[HOST]-[SRP]-[SL/WL]-[PG]-RE | N/A | Synchronous |
|
||
+----------------------------+---------------------------------+--------------------------------+--------------------+
|
||
| OS-[SRP]-[SL]-[WL]-RA-SG | OS-[HOST]-[SRP]-[SL/WL]-[PG]-RA | OS-[RDFG]-Asynchronous-rdf-sg | Asynchronous |
|
||
+----------------------------+---------------------------------+--------------------------------+--------------------+
|
||
| OS-[SRP]-[SL]-[WL]-RM-SG | OS-[HOST]-[SRP]-[SL/WL]-[PG]-RM | OS-[RDFG]-Metro-rdf-sg | Metro |
|
||
+----------------------------+---------------------------------+--------------------------------+--------------------+
|
||
|
||
|
||
PowerMax driver integration
|
||
===========================
|
||
|
||
1. Prerequisites
|
||
----------------
|
||
|
||
#. Download Solutions Enabler from `Dell EMC Support`_ and install it.
|
||
|
||
You can install Solutions Enabler on a non-OpenStack host. Supported
|
||
platforms include different flavors of Windows, Red Hat, and SUSE Linux.
|
||
Solutions Enabler can be installed on a physical server, or as a Virtual
|
||
Appliance (a VMware ESX server VM). Additionally, starting with HYPERMAX
|
||
OS Q3 2015, you can manage VMAX3 arrays using the Embedded Management
|
||
(eManagement) container application. See the ``Dell EMC Solutions Enabler
|
||
9.2.1 Installation and Configuration Guide`` on `Dell EMC Support`_ for
|
||
more details.
|
||
|
||
.. note::
|
||
|
||
You must discover storage arrays before you can use the PowerMax drivers.
|
||
Follow instructions in ``Dell EMC Solutions Enabler 9.2.1 Installation
|
||
and Configuration Guide`` on `Dell EMC Support`_ for more details.
|
||
|
||
#. Download Unisphere from `Dell EMC Support`_ and install it.
|
||
|
||
Unisphere can be installed in local, remote, or embedded configurations
|
||
- i.e., on the same server running Solutions Enabler; on a server
|
||
connected to the Solutions Enabler server; or using the eManagement
|
||
container application (containing Solutions Enabler and Unisphere for
|
||
PowerMax). See ``Dell EMC Solutions Enabler 9.2.1 Installation and
|
||
Configuration Guide`` at `Dell EMC Support`_.
|
||
|
||
|
||
2. FC zoning with PowerMax
|
||
--------------------------
|
||
|
||
Zone Manager is required when there is a fabric between the host and array.
|
||
This is necessary for larger configurations where pre-zoning would be too
|
||
complex and open-zoning would raise security concerns.
|
||
|
||
3. iSCSI with PowerMax
|
||
----------------------
|
||
|
||
- Make sure the ``open-iscsi`` package (or distro equivalent) is installed
|
||
on all Compute nodes.
|
||
|
||
.. note::
|
||
|
||
You can only ping the PowerMax iSCSI target ports when there is a valid
|
||
masking view. An attach operation creates this masking view.
|
||
|
||
|
||
|
||
4. Configure block storage in cinder.conf
|
||
-----------------------------------------
|
||
|
||
.. config-table::
|
||
:config-target: PowerMax
|
||
|
||
cinder.volume.drivers.dell_emc.powermax.common
|
||
|
||
|
||
.. note::
|
||
|
||
``san_api_port`` is ``8443`` by default but can be changed if
|
||
necessary. For the purposes of this documentation the default is
|
||
assumed so the tag will not appear in any of the ``cinder.conf``
|
||
extracts below.
|
||
|
||
|
||
.. note::
|
||
|
||
PowerMax ``PortGroups`` must be pre-configured to expose volumes managed
|
||
by the array. Port groups can be supplied in ``cinder.conf``, or
|
||
can be specified as an extra spec ``storagetype:portgroupname`` on a
|
||
volume type. If a port group is set on a volume type as an extra
|
||
specification it takes precedence over any port groups set in
|
||
``cinder.conf``. For more information on port and port group selection
|
||
please see the section ``port group & port load balancing``.
|
||
|
||
.. note::
|
||
|
||
PowerMax ``SRP`` cannot be changed once configured and in-use. SRP renaming
|
||
on the PowerMax array is not supported.
|
||
|
||
.. note::
|
||
|
||
Service Level can be added to ``cinder.conf`` when the backend is the
|
||
default case and there is no associated volume type. This not a recommended
|
||
configuration as it is too restrictive. Workload is ``NONE`` for PowerMax
|
||
and any All Flash with PowerMax OS (5978) or greater.
|
||
|
||
+--------------------+----------------------------+----------+----------+
|
||
| PowerMax parameter | cinder.conf parameter | Default | Required |
|
||
+====================+============================+==========+==========+
|
||
| ``ServiceLevel`` | ``powermax_service_level`` | ``None`` | No |
|
||
+--------------------+----------------------------+----------+----------+
|
||
|
||
|
||
To configure PowerMax block storage, add the following entries to
|
||
``/etc/cinder/cinder.conf``:
|
||
|
||
.. code-block:: ini
|
||
|
||
enabled_backends = CONF_GROUP_ISCSI, CONF_GROUP_FC
|
||
|
||
[CONF_GROUP_ISCSI]
|
||
volume_driver = cinder.volume.drivers.dell_emc.powermax.iscsi.PowerMaxISCSIDriver
|
||
volume_backend_name = POWERMAX_ISCSI
|
||
powermax_port_groups = [OS-ISCSI-PG]
|
||
san_ip = 10.10.10.10
|
||
san_login = my_username
|
||
san_password = my_password
|
||
powermax_array = 000123456789
|
||
powermax_srp = SRP_1
|
||
|
||
|
||
[CONF_GROUP_FC]
|
||
volume_driver = cinder.volume.drivers.dell_emc.powermax.fc.PowerMaxFCDriver
|
||
volume_backend_name = POWERMAX_FC
|
||
powermax_port_groups = [OS-FC-PG]
|
||
san_ip = 10.10.10.10
|
||
san_login = my_username
|
||
san_password = my_password
|
||
powermax_array = 000123456789
|
||
powermax_srp = SRP_1
|
||
|
||
In this example, two back-end configuration groups are enabled:
|
||
``CONF_GROUP_ISCSI`` and ``CONF_GROUP_FC``. Each configuration group has a
|
||
section describing unique parameters for connections, drivers and the
|
||
``volume_backend_name``.
|
||
|
||
|
||
5. SSL support
|
||
--------------
|
||
|
||
#. Get the CA certificate of the Unisphere server. This pulls the CA cert file
|
||
and saves it as ``.pem`` file:
|
||
|
||
.. code-block:: console
|
||
|
||
# openssl s_client -showcerts \
|
||
-connect my_unisphere_host:8443 \
|
||
</dev/null 2>/dev/null \
|
||
| openssl x509 -outform PEM > my_unisphere_host.pem
|
||
|
||
Where ``my_unisphere_host`` is the hostname of the unisphere instance and
|
||
``my_unisphere_host.pem`` is the name of the ``.pem`` file.
|
||
|
||
#. Add this path to ``cinder.conf`` under the PowerMax backend stanza and set
|
||
SSL verify to ``True``
|
||
|
||
.. code-block:: console
|
||
|
||
driver_ssl_cert_verify = True
|
||
driver_ssl_cert_path = /path/to/my_unisphere_host.pem
|
||
|
||
``OR`` follow the steps 3-6 below if you would like to add the CA cert to
|
||
the system certificate bundle instead of specifying the path to cert:
|
||
|
||
#. OPTIONAL: Copy the ``.pem`` cert to the system certificate
|
||
directory and convert to ``.crt``:
|
||
|
||
.. code-block:: console
|
||
|
||
# cp my_unisphere_host.pem /usr/share/ca-certificates/ca_cert.crt
|
||
|
||
#. OPTIONAL: Update CA certificate database with the following command. Ensure
|
||
you select to enable the cert from step 3 when prompted:
|
||
|
||
.. code-block:: console
|
||
|
||
# sudo dpkg-reconfigure ca-certificates
|
||
|
||
#. OPTIONAL: Set a system environment variable to tell the Requests library to
|
||
use the system cert bundle instead of the default Certifi bundle:
|
||
|
||
.. code-block:: console
|
||
|
||
# export REQUESTS_CA_BUNDLE = /etc/ssl/certs/ca-certificates.crt
|
||
|
||
#. OPTIONAL: Set cert verification to ``True`` under the PowerMax backend
|
||
stanza in ``cinder.conf``:
|
||
|
||
.. code-block:: console
|
||
|
||
# driver_ssl_cert_verify = True
|
||
|
||
#. Ensure ``driver_ssl_cert_verify`` is set to ``True`` in ``cinder.conf``
|
||
backend stanzas if steps 3-6 are followed, otherwise ensure both
|
||
``driver_ssl_cert_path`` and ``driver_ssl_cert_verify`` are set in
|
||
``cinder.conf`` backend stanzas.
|
||
|
||
|
||
6. Create volume types
|
||
----------------------
|
||
|
||
Once ``cinder.conf`` has been updated, `Openstack CLI`_ commands need to be
|
||
issued in order to create and associate OpenStack volume types with the
|
||
declared ``volume_backend_names``.
|
||
|
||
Additionally, each volume type will need an associated ``pool_name`` - an
|
||
extra specification indicating the service level/ workload combination to
|
||
be used for that volume type.
|
||
|
||
|
||
.. note::
|
||
|
||
The ``pool_name`` is an additional property which has to be set and is of
|
||
the format: ``<ServiceLevel>+<SRP>+<Array ID>``. This can be obtained from
|
||
the output of the ``cinder get-pools--detail``. Workload is NONE for
|
||
PowerMax or any All Flash with PowerMax OS (5978) or greater.
|
||
|
||
|
||
There is also the option to assign a port group to a volume type by
|
||
setting the ``storagetype:portgroupname`` extra specification.
|
||
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume type create POWERMAX_ISCSI_SILVER
|
||
$ openstack volume type set --property volume_backend_name=ISCSI_backend \
|
||
--property pool_name=Silver+SRP_1+000123456789 \
|
||
--property storagetype:portgroupname=OS-PG2 \
|
||
POWERMAX_ISCSI_SILVER
|
||
$ openstack volume type create POWERMAX_FC_DIAMOND
|
||
$ openstack volume type set --property volume_backend_name=FC_backend \
|
||
--property pool_name=Gold+SRP_1+000123456789 \
|
||
--property storagetype:portgroupname=OS-PG1 \
|
||
POWERMAX_FC_GOLD
|
||
|
||
|
||
By issuing these commands, the Block Storage volume type
|
||
``POWERMAX_ISCSI_SILVER`` is associated with the ``ISCSI_backend``, a Silver
|
||
Service Level.
|
||
|
||
The type ``POWERMAX_FC_DIAMOND`` is associated with the ``FC_backend``, a
|
||
Diamond Service Level.
|
||
|
||
The ``ServiceLevel`` manages the underlying storage to provide expected
|
||
performance. Setting the ``ServiceLevel`` to ``None`` means that non-FAST
|
||
managed storage groups will be created instead (storage groups not
|
||
associated with any service level).
|
||
|
||
.. code-block:: console
|
||
|
||
openstack volume type set --property pool_name=None+SRP_1+000123456789
|
||
|
||
.. note::
|
||
|
||
PowerMax and VMAX-Hybrid_ support ``Diamond``, ``Platinum``, ``Gold``,
|
||
``Silver``, ``Bronze``, ``Optimized``, and ``None`` service
|
||
levels. VMAX All Flash running HyperMax OS (5977) supports ``Diamond``
|
||
and ``None``. VMAX-Hybrid_ and All Flash support ``DSS_REP``, ``DSS``,
|
||
``OLTP_REP``, ``OLTP``, and ``None`` workloads, the latter up until
|
||
ucode 5977. Please refer to Stein PowerMax online documentation if you
|
||
wish to use ``workload``. There is no support for workloads in PowerMax
|
||
OS (5978) or greater. These will be silently ignored if set for VMAX
|
||
All-Flash arrays which have been upgraded to PowerMax OS (5988).
|
||
|
||
|
||
7. Interval and retries
|
||
-----------------------
|
||
|
||
By default, ``interval`` and ``retries`` are ``3`` seconds and ``200`` retries
|
||
respectively. These determine how long (``interval``) and how many times
|
||
(``retries``) a user is willing to wait for a single Rest call,
|
||
``3*200=600seconds``. Depending on usage, these may need to be overridden by
|
||
the user in ``cinder.conf``. For example, if performance is a factor, then the
|
||
``interval`` should be decreased to check the job status more frequently, and
|
||
if multiple concurrent provisioning requests are issued then ``retries``
|
||
should be increased so calls will not timeout prematurely.
|
||
|
||
In the example below, the driver checks every 3 seconds for the status of the
|
||
job. It will continue checking for 200 retries before it times out.
|
||
|
||
Add the following lines to the PowerMax backend in ``cinder.conf``:
|
||
|
||
.. code-block:: console
|
||
|
||
[CONF_GROUP_ISCSI]
|
||
volume_driver = cinder.volume.drivers.dell_emc.powermax.iscsi.PowerMaxISCSIDriver
|
||
volume_backend_name = POWERMAX_ISCSI
|
||
powermax_port_groups = [OS-ISCSI-PG]
|
||
san_ip = 10.10.10.10
|
||
san_login = my_username
|
||
san_password = my_password
|
||
powermax_array = 000123456789
|
||
powermax_srp = SRP_1
|
||
interval = 1
|
||
retries = 700
|
||
|
||
8. CHAP authentication support
|
||
------------------------------
|
||
|
||
This supports one-way initiator CHAP authentication functionality into the
|
||
PowerMax backend. With CHAP one-way authentication, the storage array
|
||
challenges the host during the initial link negotiation process and expects
|
||
to receive a valid credential and CHAP secret in response. When challenged,
|
||
the host transmits a CHAP credential and CHAP secret to the storage array.
|
||
The storage array looks for this credential and CHAP secret which stored in
|
||
the host initiator's initiator group (IG) information in the ACLX database.
|
||
Once a positive authentication occurs, the storage array sends an acceptance
|
||
message to the host. However, if the storage array fails to find any record
|
||
of the credential/secret pair, it sends a rejection message, and the link is
|
||
closed.
|
||
|
||
Assumptions, restrictions and prerequisites
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
#. The host initiator IQN is required along with the credentials the host
|
||
initiator will use to log into the storage array with. The same credentials
|
||
should be used in a multi node system if connecting to the same array.
|
||
|
||
#. Enable one-way CHAP authentication for the iSCSI initiator on the storage
|
||
array using ``SYMCLI``. Template and example shown below. For the purpose of
|
||
this setup, the credential/secret used would be ``my_username/my_password``
|
||
with iSCSI initiator of ``iqn.1991-05.com.company.lcseb130``
|
||
|
||
.. code-block:: console
|
||
|
||
# symaccess -sid <SymmID> -iscsi <iscsi> \
|
||
{enable chap | disable chap | set chap} \
|
||
-cred <Credential> -secret <Secret>
|
||
|
||
# symaccess -sid 128 \
|
||
-iscsi iqn.1991-05.com.company.lcseb130 \
|
||
set chap -cred my_username -secret my_password
|
||
|
||
|
||
|
||
Settings and configuration
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
#. Set the configuration in the PowerMax backend group in ``cinder.conf`` using
|
||
the following parameters and restart cinder.
|
||
|
||
+-----------------------+-------------------------+-------------------+
|
||
| Configuration options | Value required for CHAP | Required for CHAP |
|
||
+=======================+=========================+===================+
|
||
| ``use_chap_auth`` | ``True`` | Yes |
|
||
+-----------------------+-------------------------+-------------------+
|
||
| ``chap_username`` | ``my_username`` | Yes |
|
||
+-----------------------+-------------------------+-------------------+
|
||
| ``chap_password`` | ``my_password`` | Yes |
|
||
+-----------------------+-------------------------+-------------------+
|
||
|
||
.. code-block:: ini
|
||
|
||
[POWERMAX_ISCSI]
|
||
volume_driver = cinder.volume.drivers.dell_emc.powermax.iscsi.PowerMaxISCSIDriver
|
||
volume_backend_name = POWERMAX_ISCSI
|
||
san_ip = 10.10.10.10
|
||
san_login = my_u4v_username
|
||
san_password = my_u4v_password
|
||
powermax_srp = SRP_1
|
||
powermax_array = 000123456789
|
||
powermax_port_groups = [OS-ISCSI-PG]
|
||
use_chap_auth = True
|
||
chap_username = my_username
|
||
chap_password = my_password
|
||
|
||
|
||
Usage
|
||
~~~~~
|
||
|
||
#. Using ``SYMCLI``, enable CHAP authentication for a host initiator as
|
||
described above, but do not set ``use_chap_auth``, ``chap_username`` or
|
||
``chap_password`` in ``cinder.conf``. Create a bootable volume.
|
||
|
||
.. code-block:: console
|
||
|
||
openstack volume create --size 1 \
|
||
--image <image_name> \
|
||
--type <volume_type> \
|
||
test
|
||
|
||
#. Boot instance named ``test_server`` using the volume created above:
|
||
|
||
.. code-block:: console
|
||
|
||
openstack server create --volume test \
|
||
--flavor m1.small \
|
||
--nic net-id=private \
|
||
test_server
|
||
|
||
#. Verify the volume operation succeeds but the boot instance fails as
|
||
CHAP authentication fails.
|
||
|
||
#. Update ``cinder.conf`` with ``use_chap_auth`` set to true and
|
||
``chap_username`` and ``chap_password`` set with the correct credentials.
|
||
|
||
#. Rerun ``openstack server create``
|
||
|
||
#. Verify that the boot instance operation ran correctly and the volume is
|
||
accessible.
|
||
|
||
#. Verify that both the volume and boot instance operations ran successfully
|
||
and the user is able to access the volume.
|
||
|
||
|
||
|
||
9. QoS (Quality of Service) support
|
||
-----------------------------------
|
||
|
||
Quality of service (QoS) has traditionally been associated with network
|
||
bandwidth usage. Network administrators set limitations on certain networks
|
||
in terms of bandwidth usage for clients. This enables them to provide a
|
||
tiered level of service based on cost. The Nova/Cinder QoS offer similar
|
||
functionality based on volume type setting limits on host storage bandwidth
|
||
per service offering. Each volume type is tied to specific QoS attributes
|
||
some of which are unique to each storage vendor. In the hypervisor, the QoS
|
||
limits the following:
|
||
|
||
- Limit by throughput - Total bytes/sec, read bytes/sec, write bytes/sec
|
||
- Limit by IOPS - Total IOPS/sec, read IOPS/sec, write IOPS/sec
|
||
|
||
QoS enforcement in Cinder is done either at the hyper-visor (front-end),
|
||
the storage subsystem (back-end), or both. This section focuses on QoS
|
||
limits that are enforced by either the PowerMax backend and the hyper-visor
|
||
front end interchangeably or just back end (Vendor Specific). The PowerMax
|
||
driver offers support for Total bytes/sec limit in throughput and Total
|
||
IOPS/sec limit of IOPS.
|
||
|
||
The PowerMax driver supports the following attributes that are front
|
||
end/back end agnostic
|
||
|
||
- ``total_iops_sec`` - Maximum IOPs (in I/Os per second). Valid values range
|
||
from 100 IO/Sec to 100000 IO/sec.
|
||
- ``total_bytes_sec`` - Maximum bandwidth (throughput) in bytes per second.
|
||
Valid values range from 1048576 bytes (1MB) to 104857600000 bytes (100,000MB)
|
||
|
||
The PowerMax driver offers the following attribute that is vendor specific to
|
||
the PowerMax and dependent on the ``total_iops_sec`` and/or ``total_bytes_sec``
|
||
being set.
|
||
|
||
- ``Dynamic Distribution`` - Enables/Disables dynamic distribution of host I/O
|
||
limits. Possible values are:
|
||
|
||
- ``Always`` - Enables full dynamic distribution mode. When enabled, the
|
||
configured host I/O limits will be dynamically distributed across the
|
||
configured ports, thereby allowing the limits on each individual port to
|
||
adjust to fluctuating demand.
|
||
- ``OnFailure`` - Enables port failure capability. When enabled, the fraction
|
||
of configured host I/O limits available to a configured port will adjust
|
||
based on the number of ports currently online.
|
||
- ``Never`` - Disables this feature (Default).
|
||
|
||
USE CASE 1 - Default values
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
Prerequisites - PowerMax
|
||
|
||
- Host I/O Limit (MB/Sec) - No Limit
|
||
- Host I/O Limit (IO/Sec) - No Limit
|
||
- Set Dynamic Distribution - N/A
|
||
|
||
.. table:: **Prerequisites - Block Storage (Cinder) back-end (storage group)**
|
||
|
||
+-----------------------+-----------------------+
|
||
| Key | Value |
|
||
+=======================+=======================+
|
||
| ``total_iops_sec`` | ``500`` |
|
||
+-----------------------+-----------------------+
|
||
| ``total_bytes_sec`` | ``104857600`` (100MB) |
|
||
+-----------------------+-----------------------+
|
||
| ``DistributionType`` | ``Always`` |
|
||
+-----------------------+-----------------------+
|
||
|
||
#. Create QoS Specs with the prerequisite values above:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume qos create --consumer back-end \
|
||
--property total_iops_sec=500 \
|
||
--property total_bytes_sec=104857600 \
|
||
--property DistributionType=Always \
|
||
my_qos
|
||
|
||
#. Associate QoS specs with specified volume type:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume qos associate my_qos my_volume_type
|
||
|
||
#. Create volume with the volume type indicated above:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume create --size 1 --type my_volume_type my_volume
|
||
|
||
**Outcome - PowerMax (storage group)**
|
||
|
||
- Host I/O Limit (MB/Sec) - ``100``
|
||
- Host I/O Limit (IO/Sec) - ``500``
|
||
- Set Dynamic Distribution - ``Always``
|
||
|
||
**Outcome - Block Storage (Cinder)**
|
||
|
||
Volume is created against volume type and QoS is enforced with the parameters
|
||
above.
|
||
|
||
USE CASE 2 - Pre-set limits
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
Prerequisites - PowerMax
|
||
|
||
- Host I/O Limit (MB/Sec) - ``2000``
|
||
- Host I/O Limit (IO/Sec) - ``2000``
|
||
- Set Dynamic Distribution - ``Never``
|
||
|
||
.. table:: **Prerequisites - Block Storage (Cinder) back-end (storage group)**
|
||
|
||
+-----------------------+-----------------------+
|
||
| Key | Value |
|
||
+=======================+=======================+
|
||
| ``total_iops_sec`` | ``500`` |
|
||
+-----------------------+-----------------------+
|
||
| ``total_bytes_sec`` | ``104857600`` (100MB) |
|
||
+-----------------------+-----------------------+
|
||
| ``DistributionType`` | ``Always`` |
|
||
+-----------------------+-----------------------+
|
||
|
||
#. Create QoS specifications with the prerequisite values above. The consumer
|
||
in this use case is both for front-end and back-end:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume qos create --consumer back-end \
|
||
--property total_iops_sec=500 \
|
||
--property total_bytes_sec=104857600 \
|
||
--property DistributionType=Always \
|
||
my_qos
|
||
|
||
#. Associate QoS specifications with specified volume type:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume qos associate my_qos my_volume_type
|
||
|
||
#. Create volume with the volume type indicated above:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume create --size 1 --type my_volume_type my_volume
|
||
|
||
#. Attach the volume created in step 3 to an instance
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack server add volume my_instance my_volume
|
||
|
||
**Outcome - PowerMax (storage group)**
|
||
|
||
- Host I/O Limit (MB/Sec) - ``100``
|
||
- Host I/O Limit (IO/Sec) - ``500``
|
||
- Set Dynamic Distribution - ``Always``
|
||
|
||
**Outcome - Block Storage (Cinder)**
|
||
|
||
Volume is created against volume type and QoS is enforced with the parameters
|
||
above.
|
||
|
||
**Outcome - Hypervisor (Nova)**
|
||
|
||
``Libvirt`` includes an extra ``xml`` flag within the ``<disk>`` section called
|
||
``iotune`` that is responsible for rate limitation. To confirm that, first get
|
||
the ``OS-EXT-SRV-ATTR:instance_name`` value of the server instance,
|
||
for example ``instance-00000003``.
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack server show <serverid>
|
||
|
||
+-------------------------------------+-----------------------------------------------------------------+
|
||
| Field | Value |
|
||
+-------------------------------------+-----------------------------------------------------------------+
|
||
| OS-DCF:diskConfig | AUTO |
|
||
| OS-EXT-AZ:availability_zone | nova |
|
||
| OS-EXT-SRV-ATTR:host | myhost |
|
||
| OS-EXT-SRV-ATTR:hypervisor_hostname | myhost |
|
||
| OS-EXT-SRV-ATTR:instance_name | instance-00000003 |
|
||
| OS-EXT-STS:power_state | Running |
|
||
| OS-EXT-STS:task_state | None |
|
||
| OS-EXT-STS:vm_state | active |
|
||
| OS-SRV-USG:launched_at | 2017-11-02T08:15:42.000000 |
|
||
| OS-SRV-USG:terminated_at | None |
|
||
| accessIPv4 | |
|
||
| accessIPv6 | |
|
||
| addresses | private=fd21:99c2:73f3:0:f816:3eff:febe:30ed, 10.0.0.3 |
|
||
| config_drive | |
|
||
| created | 2017-11-02T08:15:34Z |
|
||
| flavor | m1.tiny (1) |
|
||
| hostId | e7b8312581f9fbb8508587d45c0b6fb4dc86102c632ed1f3a6a49d42 |
|
||
| id | 0ef0ff4c-dbda-4dc7-b8ed-45d2fc2f31db |
|
||
| image | cirros-0.3.5-x86_64-disk (b7c220f5-2408-4296-9e58-fc5a41cb7e9d) |
|
||
| key_name | myhostname |
|
||
| name | myhosthame |
|
||
| progress | 0 |
|
||
| project_id | bae4b97a0d8b42c28a5add483981e5db |
|
||
| properties | |
|
||
| security_groups | name='default' |
|
||
| status | ACTIVE |
|
||
| updated | 2017-11-02T08:15:42Z |
|
||
| user_id | 7bccf456740546799a7e20457f13c38b |
|
||
| volumes_attached | |
|
||
+-------------------------------------+-----------------------------------------------------------------+
|
||
|
||
We then run the following command using the ``OS-EXT-SRV-ATTR:instance_name``
|
||
retrieved above.
|
||
|
||
.. code-block:: console
|
||
|
||
$ virsh dumpxml instance-00000003 | grep -1 "total_bytes_sec\|total_iops_sec"
|
||
|
||
The output of the command contains the XML below. It is found between the
|
||
``<disk>`` start and end tag.
|
||
|
||
.. code-block:: xml
|
||
|
||
<iotune>
|
||
<total_bytes_sec>104857600</total_bytes_sec>
|
||
<total_iops_sec>500</total_iops_sec>
|
||
</iotune>
|
||
|
||
|
||
USE CASE 3 - Pre-set limits
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
Prerequisites - PowerMax
|
||
|
||
- Host I/O Limit (MB/Sec) - ``100``
|
||
- Host I/O Limit (IO/Sec) - ``500``
|
||
- Set Dynamic Distribution - ``Always``
|
||
|
||
.. table:: **Prerequisites - Block Storage (Cinder) back end (storage group)**
|
||
|
||
+-----------------------+-----------------------+
|
||
| Key | Value |
|
||
+=======================+=======================+
|
||
| ``total_iops_sec`` | ``500`` |
|
||
+-----------------------+-----------------------+
|
||
| ``total_bytes_sec`` | ``104857600`` (100MB) |
|
||
+-----------------------+-----------------------+
|
||
| ``DistributionType`` | ``OnFailure`` |
|
||
+-----------------------+-----------------------+
|
||
|
||
#. Create QoS specifications with the prerequisite values above:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume qos create --consumer back-end \
|
||
--property total_iops_sec=500 \
|
||
--property total_bytes_sec=104857600 \
|
||
--property DistributionType=OnFailure \
|
||
my_qos
|
||
|
||
#. Associate QoS specifications with specified volume type:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume qos associate my_qos my_volume_type
|
||
|
||
#. Create volume with the volume type indicated above:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume create --size 1 --type my_volume_type my_volume
|
||
|
||
**Outcome - PowerMax (storage group)**
|
||
|
||
- Host I/O Limit (MB/Sec) - ``100``
|
||
- Host I/O Limit (IO/Sec) - ``500``
|
||
- Set Dynamic Distribution - ``OnFailure``
|
||
|
||
**Outcome - Block Storage (Cinder)**
|
||
|
||
Volume is created against volume type and QOS is enforced with the parameters
|
||
above.
|
||
|
||
|
||
USE CASE 4 - Default values
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
Prerequisites - PowerMax
|
||
|
||
- Host I/O Limit (MB/Sec) - ``No Limit``
|
||
- Host I/O Limit (IO/Sec) - ``No Limit``
|
||
- Set Dynamic Distribution - ``N/A``
|
||
|
||
.. table:: **Prerequisites - Block Storage (Cinder) back end (storage group)**
|
||
|
||
+-----------------------+---------------+
|
||
| Key | Value |
|
||
+=======================+===============+
|
||
| ``DistributionType`` | ``Always`` |
|
||
+-----------------------+---------------+
|
||
|
||
#. Create QoS specifications with the prerequisite values above:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume qos create --consumer back-end \
|
||
--property DistributionType=Always \
|
||
my_qos
|
||
|
||
#. Associate QoS specifications with specified volume type:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume qos associate my_qos my_volume_type
|
||
|
||
|
||
#. Create volume with the volume type indicated above:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume create --size 1 --type my_volume_type my_volume
|
||
|
||
**Outcome - PowerMax (storage group)**
|
||
|
||
- Host I/O Limit (MB/Sec) - ``No Limit``
|
||
- Host I/O Limit (IO/Sec) - ``No Limit``
|
||
- Set Dynamic Distribution - ``N/A``
|
||
|
||
**Outcome - Block Storage (Cinder)**
|
||
|
||
Volume is created against volume type and there is no QoS change.
|
||
|
||
10. Multi-pathing support
|
||
-------------------------
|
||
|
||
- Install ``open-iscsi`` on all nodes on your system if on an iSCSI setup.
|
||
- Do not install EMC PowerPath as they cannot co-exist with native multi-path
|
||
software
|
||
- Multi-path tools must be installed on all Nova compute nodes
|
||
|
||
On Ubuntu:
|
||
|
||
.. code-block:: console
|
||
|
||
# apt-get install multipath-tools #multipath modules
|
||
# apt-get install sysfsutils sg3-utils #file system utilities
|
||
# apt-get install scsitools #SCSI tools
|
||
|
||
On openSUSE and SUSE Linux Enterprise Server:
|
||
|
||
.. code-block:: console
|
||
|
||
# zipper install multipath-tools #multipath modules
|
||
# zipper install sysfsutils sg3-utils #file system utilities
|
||
# zipper install scsitools #SCSI tools
|
||
|
||
On Red Hat Enterprise Linux and CentOS:
|
||
|
||
.. code-block:: console
|
||
|
||
# yum install iscsi-initiator-utils #ensure iSCSI is installed
|
||
# yum install device-mapper-multipath #multipath modules
|
||
# yum install sysfsutils sg3-utils #file system utilities
|
||
|
||
|
||
Multipath configuration file
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
The multi-path configuration file may be edited for better management and
|
||
performance. Log in as a privileged user and make the following changes to
|
||
``/etc/multipath.conf`` on the Compute (Nova) node(s).
|
||
|
||
.. code-block:: vim
|
||
|
||
devices {
|
||
# Device attributed for EMC PowerMax
|
||
device {
|
||
vendor "EMC"
|
||
product "SYMMETRIX"
|
||
path_grouping_policy multibus
|
||
getuid_callout "/lib/udev/scsi_id --page=pre-spc3-83 --whitelisted --device=/dev/%n"
|
||
path_selector "round-robin 0"
|
||
path_checker tur
|
||
features "0"
|
||
hardware_handler "0"
|
||
prio const
|
||
rr_weight uniform
|
||
no_path_retry 6
|
||
rr_min_io 1000
|
||
rr_min_io_rq 1
|
||
}
|
||
}
|
||
|
||
You may need to reboot the host after installing the MPIO tools or restart
|
||
iSCSI and multi-path services.
|
||
|
||
On Ubuntu iSCSI:
|
||
|
||
.. code-block:: console
|
||
|
||
# service open-iscsi restart
|
||
# service multipath-tools restart
|
||
|
||
On Ubuntu FC
|
||
|
||
.. code-block:: console
|
||
|
||
# service multipath-tools restart
|
||
|
||
|
||
On openSUSE, SUSE Linux Enterprise Server, Red Hat Enterprise Linux, and
|
||
CentOS iSCSI:
|
||
|
||
.. code-block:: console
|
||
|
||
# systemctl restart open-iscsi
|
||
# systemctl restart multipath-tools
|
||
|
||
|
||
On openSUSE, SUSE Linux Enterprise Server, Red Hat Enterprise Linux, and
|
||
CentOS FC:
|
||
|
||
.. code-block:: console
|
||
|
||
# systemctl restart multipath-tools
|
||
|
||
|
||
.. code-block:: console
|
||
|
||
$ lsblk
|
||
NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINT
|
||
sda 8:0 0 1G 0 disk
|
||
..360000970000196701868533030303235 (dm-6) 252:6 0 1G 0 mpath
|
||
sdb 8:16 0 1G 0 disk
|
||
..360000970000196701868533030303235 (dm-6) 252:6 0 1G 0 mpath
|
||
vda 253:0 0 1T 0 disk
|
||
|
||
OpenStack configurations
|
||
~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
On Compute (Nova) node, add the following flag in the ``[libvirt]`` section of
|
||
``nova.conf`` and ``nova-cpu.conf``:
|
||
|
||
.. code-block:: ini
|
||
|
||
volume_use_multipath = True
|
||
|
||
On Cinder controller node, multi-path for image transfer can be enabled in
|
||
``cinder.conf`` for each backend section or in ``[backend_defaults]`` section
|
||
as a common configuration for all backends.
|
||
|
||
.. code-block:: ini
|
||
|
||
use_multipath_for_image_xfer = True
|
||
|
||
Restart ``nova-compute`` and ``cinder-volume`` services after the change.
|
||
|
||
Verify you have multiple initiators available on the compute node for I/O
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
#. Create a 3GB PowerMax volume.
|
||
#. Create an instance from image out of native LVM storage or from PowerMax
|
||
storage, for example, from a bootable volume
|
||
#. Attach the 3GB volume to the new instance:
|
||
|
||
.. code-block:: console
|
||
|
||
# multipath -ll
|
||
mpath102 (360000970000196700531533030383039) dm-3 EMC,SYMMETRIX
|
||
size=3G features='1 queue_if_no_path' hwhandler='0' wp=rw
|
||
'-+- policy='round-robin 0' prio=1 status=active
|
||
33:0:0:1 sdb 8:16 active ready running
|
||
'- 34:0:0:1 sdc 8:32 active ready running
|
||
|
||
#. Use the ``lsblk`` command to see the multi-path device:
|
||
|
||
.. code-block:: console
|
||
|
||
# lsblk
|
||
NAME MAJ:MIN RM SIZE RO TYPE
|
||
sdb 8:0 0 3G 0 disk
|
||
..360000970000196700531533030383039 (dm-6) 252:6 0 3G 0 mpath
|
||
sdc 8:16 0 3G 0 disk
|
||
..360000970000196700531533030383039 (dm-6) 252:6 0 3G 0 mpath
|
||
vda
|
||
|
||
|
||
11. All Flash compression support
|
||
---------------------------------
|
||
|
||
On an All Flash array, the creation of any storage group has a compressed
|
||
attribute by default. Setting compression on a storage group does not mean
|
||
that all the devices will be immediately compressed. It means that for all
|
||
incoming writes compression will be considered. Setting compression ``off`` on
|
||
a storage group does not mean that all the devices will be uncompressed.
|
||
It means all the writes to compressed tracks will make these tracks
|
||
uncompressed.
|
||
|
||
.. note::
|
||
|
||
This feature is only applicable for All Flash arrays, 250F, 450F, 850F
|
||
and 950F and PowerMax 2000 and 8000. It was first introduced Solutions
|
||
Enabler 8.3.0.11 or later and is enabled by default when associated with
|
||
a Service Level. This means volumes added to any newly created storage
|
||
groups will be compressed.
|
||
|
||
Use case 1 - Compression disabled create, attach, detach, and delete volume
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
#. Create a new volume type called ``POWERMAX_COMPRESSION_DISABLED``.
|
||
#. Set an extra spec ``volume_backend_name``.
|
||
#. Set a new extra spec ``storagetype:disablecompression = True``.
|
||
#. Create a new volume.
|
||
#. Check in Unisphere or SYMCLI to see if the volume
|
||
exists in storage group ``OS-<srp>-<servicelevel>-<workload>-CD-SG``, and
|
||
compression is disabled on that storage group.
|
||
#. Attach the volume to an instance. Check in Unisphere or SYMCLI to see if the
|
||
volume exists in storage group
|
||
``OS-<shorthostname>-<srp>-<servicelevel/workload>-<portgroup>-CD``, and
|
||
compression is disabled on that storage group.
|
||
#. Detach volume from instance. Check in Unisphere or symcli to see if the
|
||
volume exists in storage group ``OS-<srp>-<servicelevel>-<workload>-CD-SG``,
|
||
and compression is disabled on that storage group.
|
||
#. Delete the volume. If this was the last volume in the
|
||
``OS-<srp>-<servicelevel>-<workload>-CD-SG`` storage group,
|
||
it should also be deleted.
|
||
|
||
|
||
Use case 2 - Retype from compression disabled to compression enabled
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
#. Repeat steps 1-4 of Use case 1.
|
||
#. Create a new volume type. For example ``POWERMAX_COMPRESSION_ENABLED``.
|
||
#. Set extra spec ``volume_backend_name`` as before.
|
||
#. Set the new extra spec's compression as
|
||
``storagetype:disablecompression = False`` or DO NOT set this extra spec.
|
||
#. Retype from volume type ``POWERMAX_COMPRESSION_DISABLED`` to
|
||
``POWERMAX_COMPRESSION_ENABLED``.
|
||
#. Check in Unisphere or symcli to see if the volume exists in storage group
|
||
``OS-<srp>-<servicelevel>-<workload>-SG``, and compression is enabled on
|
||
that storage group.
|
||
|
||
.. note::
|
||
If extra spec ``storagetype:disablecompression`` is set on a VMAX-Hybrid_,
|
||
it is ignored because compression is not an available feature on a
|
||
VMAX-Hybrid_.
|
||
|
||
|
||
12. Oversubscription support
|
||
----------------------------
|
||
|
||
Please refer to the official OpenStack `over-subscription documentation`_ for
|
||
further information on using over-subscription with PowerMax.
|
||
|
||
|
||
13. Live migration support
|
||
--------------------------
|
||
|
||
**Non-live migration** (sometimes referred to simply as 'migration'). The
|
||
instance is shut down for a period of time to be moved to another hyper-visor.
|
||
In this case, the instance recognizes that it was rebooted.
|
||
|
||
**Live migration** (or 'true live migration'). Almost no instance downtime.
|
||
Useful when the instances must be kept running during the migration. The
|
||
different types of live migration are:
|
||
|
||
- **Shared storage-based live migration** Both hyper-visors have access to
|
||
shared storage.
|
||
|
||
- **Block live migration** No shared storage is required. Incompatible with
|
||
read-only devices such as CD-ROMs and Configuration Drive (config_drive).
|
||
|
||
- **Volume-backed live migration** Instances are backed by volumes rather than
|
||
ephemeral disk. For PowerMax volume-backed live migration, shared storage
|
||
is required.
|
||
|
||
The PowerMax driver supports shared volume-backed live migration.
|
||
|
||
Architecture
|
||
~~~~~~~~~~~~
|
||
|
||
In PowerMax, A volume cannot belong to two or more FAST storage groups at the
|
||
same time. To get around this limitation we leverage both cascaded storage
|
||
groups and a temporary non-FAST storage group.
|
||
|
||
A volume can remain 'live' if moved between masking views that have the same
|
||
initiator group and port groups which preserves the host path.
|
||
|
||
During live migration, the following steps are performed by the PowerMax driver
|
||
on the volume:
|
||
|
||
#. Within the originating masking view, the volume is moved from the FAST
|
||
storage group to the non-FAST storage group within the parent storage
|
||
group.
|
||
#. The volume is added to the FAST storage group within the destination
|
||
parent storage group of the destination masking view. At this point the
|
||
volume belongs to two storage groups.
|
||
#. One of two things happen:
|
||
|
||
- If the connection to the destination instance is successful, the volume
|
||
is removed from the non-FAST storage group in the originating masking
|
||
view, deleting the storage group if it contains no other volumes.
|
||
- If the connection to the destination instance fails, the volume is
|
||
removed from the destination storage group, deleting the storage group,
|
||
if empty. The volume is reverted back to the original storage group.
|
||
|
||
|
||
Live migration configuration
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
Please refer to the official OpenStack documentation on
|
||
`configuring migrations`_ and `live migration usage`_ for more information.
|
||
|
||
.. note::
|
||
|
||
OpenStack Oslo uses an open standard for messaging middleware known as
|
||
``AMQP``. This messaging middleware (the RPC messaging system) enables the
|
||
OpenStack services that run on multiple servers to talk to each other.
|
||
By default, the RPC messaging client is set to timeout after 60 seconds,
|
||
meaning if any operation you perform takes longer than 60 seconds to
|
||
complete the operation will timeout and fail with the ERROR message
|
||
``Messaging Timeout: Timed out waiting for a reply to message ID``
|
||
``[message_id]``
|
||
|
||
If this occurs, increase the ``rpc_response_timeout`` flag value in
|
||
``cinder.conf`` and ``nova.conf`` on all Cinder and Nova nodes and restart
|
||
the services.
|
||
|
||
What to change this value to will depend entirely on your own environment,
|
||
you might only need to increase it slightly, or if your environment is
|
||
under heavy network load it could need a bit more time than normal. Fine
|
||
tuning is required here, change the value and run intensive operations to
|
||
determine if your timeout value matches your environment requirements.
|
||
|
||
At a minimum please set ``rpc_response_timeout`` to ``240``, but this will
|
||
need to be raised if high concurrency is a factor. This should be
|
||
sufficient for all Cinder backup commands also.
|
||
|
||
|
||
System configuration
|
||
~~~~~~~~~~~~~~~~~~~~
|
||
|
||
``NOVA-INST-DIR/instances/`` (for example, ``/opt/stack/data/nova/instances``)
|
||
has to be mounted by shared storage. Ensure that ``NOVA-INST-DIR`` (set with
|
||
``state_path`` in the ``nova.conf`` file) is the same on all hosts.
|
||
|
||
#. Configure your DNS or ``/etc/hosts`` and ensure it is consistent across all
|
||
hosts. Make sure that the three hosts can perform name resolution with each
|
||
other. As a test, use the ping command to ping each host from one another.
|
||
|
||
.. code-block:: console
|
||
|
||
$ ping HostA
|
||
$ ping HostB
|
||
$ ping HostC
|
||
|
||
#. Export ``NOVA-INST-DIR/instances`` from ``HostA``, and ensure it is readable
|
||
and writable by the Compute user on ``HostB`` and ``HostC``. Please refer to
|
||
the relevant OS documentation for further details, for example
|
||
`Ubuntu NFS Documentation`_
|
||
|
||
#. On all compute nodes, enable the ``execute/search`` bit on your shared
|
||
directory to allow ``qemu`` to be able to use the images within the
|
||
directories. On all hosts, run the following command:
|
||
|
||
.. code-block:: console
|
||
|
||
$ chmod o+x NOVA-INST-DIR/instances
|
||
|
||
.. note::
|
||
|
||
If migrating from compute to controller, make sure to run step two above on
|
||
the controller node to export the instance directory.
|
||
|
||
|
||
Use case
|
||
~~~~~~~~
|
||
|
||
For our use case shown below, we have three hosts with host names ``HostA``,
|
||
``HostB`` and ``HostC``. ``HostA`` is the controller node while ``HostB`` and
|
||
``HostC`` are the compute nodes. The following were also used in live
|
||
migration.
|
||
|
||
- 2GB bootable volume using the CirrOS image.
|
||
- Instance created using the 2GB volume above with a flavor ``m1.small`` using
|
||
2048 RAM, 20GB of Disk and 1 VCPU.
|
||
|
||
#. Create a bootable volume.
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume create --size 2 \
|
||
--image cirros-0.3.5-x86_64-disk \
|
||
--volume_lm_1
|
||
|
||
#. Launch an instance using the volume created above on ``HostB``.
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack server create --volume volume_lm_1 \
|
||
--flavor m1.small \
|
||
--nic net-id=private \
|
||
--security-group default \
|
||
--availability-zone nova:HostB \
|
||
server_lm_1
|
||
|
||
#. Confirm on ``HostB`` has the instance created by running:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack server show server_lm_1 | grep "hypervisor_hostname\|instance_name"
|
||
| OS-EXT-SRV-ATTR:hypervisor_hostname | HostB
|
||
| OS-EXT-SRV-ATTR:instance_name | instance-00000006
|
||
|
||
#. Confirm, through ``virsh`` using the instance_name returned in step 3
|
||
(``instance-00000006``), on ``HostB`` that the instance is created using:
|
||
|
||
.. code-block:: console
|
||
|
||
$ virsh list --all
|
||
|
||
Id Name State
|
||
--------------------------------
|
||
1 instance-00000006 Running
|
||
|
||
#. Migrate the instance from ``HostB`` to ``HostA`` with:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack server migrate --os-compute-api-version 2.30 \
|
||
--live-migration --host HostA \
|
||
server_lm_1
|
||
|
||
#. Run the command on step 3 above when the instance is back in available
|
||
status. The hypervisor should be on Host A.
|
||
|
||
#. Run the command on Step 4 on Host A to confirm that the instance is
|
||
created through ``virsh``.
|
||
|
||
|
||
14. Multi-attach support
|
||
------------------------
|
||
|
||
PowerMax cinder driver supports the ability to attach a volume to multiple
|
||
hosts/servers simultaneously. Please see the official OpenStack
|
||
`multi-attach documentation`_ for configuration information.
|
||
|
||
Multi-attach architecture
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
In PowerMax, a volume cannot belong to two or more FAST storage groups at the
|
||
same time. This can cause issues when we are attaching a volume to multiple
|
||
instances on different hosts. To get around this limitation, we leverage both
|
||
cascaded storage groups and non-FAST storage groups (i.e. a storage group with
|
||
no service level, workload, or SRP specified).
|
||
|
||
.. note::
|
||
|
||
If no service level is assigned to the volume type, no extra work on the
|
||
backend is required – the volume is attached to and detached from each
|
||
host as normal.
|
||
|
||
Example use case
|
||
~~~~~~~~~~~~~~~~
|
||
|
||
Volume ``Multi-attach-Vol-1`` (with a multi-attach capable volume type, and
|
||
associated with a Diamond Service Level) is attached to Instance
|
||
``Multi-attach-Instance-A`` on HostA. We then issue the command to attach
|
||
``Multi-attach-Vol-1`` to ``Multi-attach-Instance-B`` on HostB:
|
||
|
||
#. In the ``HostA`` masking view, the volume is moved from the FAST managed
|
||
storage group to the non-FAST managed storage group within the parent
|
||
storage group.
|
||
|
||
#. The volume is attached as normal on ``HostB`` – i.e., it is added to a FAST
|
||
managed storage group within the parent storage group of the ``HostB``
|
||
masking view. The volume now belongs to two masking views, and is exposed to
|
||
both ``HostA`` and ``HostB``.
|
||
|
||
We then decide to detach the volume from ``Multi-attach-Instance-B`` on
|
||
``HostB``:
|
||
|
||
#. The volume is detached as normal from ``HostB`` – i.e., it is removed from
|
||
the FAST managed storage group within the parent storage group of the
|
||
``HostB`` masking view – this includes cleanup of the associated elements
|
||
if required. The volume now belongs to one masking view, and is no longer
|
||
exposed to ``HostB``.
|
||
|
||
#. In the ``HostA`` masking view, the volume is returned to the FAST managed
|
||
storage group from the non-FAST managed storage group within the parent
|
||
storage group. The non-FAST managed storage group is cleaned up,
|
||
if required.
|
||
|
||
|
||
15. Volume encryption support
|
||
-----------------------------
|
||
|
||
Encryption is supported through the use of OpenStack Barbican. Only front-end
|
||
encryption is supported, back-end encryption is handled at the hardware level
|
||
with `Data at Rest Encryption`_ (D@RE).
|
||
|
||
For further information on OpenStack Barbican including setup and configuration
|
||
please refer to the following `official Barbican documentation`_.
|
||
|
||
|
||
16. Volume metadata
|
||
-------------------
|
||
|
||
Volume metadata is returned to the user in both the Cinder Volume logs and
|
||
with volumes and snapshots created in Cinder via the UI or CLI.
|
||
|
||
16.1 Volume metadata in logs
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
If debug is enabled in the default section of ``cinder.conf``, PowerMax Cinder
|
||
driver will log additional volume information in the Cinder volume log,
|
||
on each successful operation. The facilitates bridging the gap between
|
||
OpenStack and the Array by tracing and describing the volume from a VMAX/
|
||
PowerMax view point.
|
||
|
||
.. code-block:: console
|
||
|
||
+------------------------------------+---------------------------------------------------------+
|
||
| Key | Value |
|
||
+------------------------------------+---------------------------------------------------------+
|
||
| service_level | Gold |
|
||
| is_compression_disabled | no |
|
||
| powermax_cinder_driver_version | 3.2.0 |
|
||
| identifier_name | OS-819470ab-a6d4-49cc-b4db-6f85e82822b7 |
|
||
| openstack_release | 13.0.0.0b3.dev3 |
|
||
| volume_id | 819470ab-a6d4-49cc-b4db-6f85e82822b7 |
|
||
| storage_model | PowerMax_8000 |
|
||
| successful_operation | delete |
|
||
| default_sg_name | OS-DEFAULT_SRP-Gold-NONE-SG |
|
||
| device_id | 01C03 |
|
||
| unisphere_for_powermax_version | V9.0.0.9 |
|
||
| workload | NONE |
|
||
| openstack_version | 13.0.0 |
|
||
| volume_updated_time | 2018-08-03 03:13:53 |
|
||
| platform | Linux-4.4.0-127-generic-x86_64-with-Ubuntu-16.04-xenial |
|
||
| python_version | 2.7.12 |
|
||
| volume_size | 20 |
|
||
| srp | DEFAULT_SRP |
|
||
| openstack_name | 90_Test_Vol56 |
|
||
| storage_firmware_version | 5978.143.144 |
|
||
| serial_number | 000123456789 |
|
||
+------------------------------------+---------------------------------------------------------+
|
||
|
||
16.2 Metadata in the UI and CLI
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
By default metadata will be set on all volume and snapshot objects created in
|
||
Cinder. This information represents the state of the object on the backend
|
||
PowerMax and will change when volume attributes are changed by performing
|
||
actions on them such as re-type or attaching to an instance.
|
||
|
||
.. code-block:: console
|
||
|
||
demo@openstack-controller:~$ cinder show powermax-volume
|
||
|
||
+--------------------------------+------------------------------------------------------------+
|
||
| Property | Value |
|
||
+--------------------------------+------------------------------------------------------------+
|
||
| metadata | ArrayID : 000123456789 |
|
||
| | ArrayModel : PowerMax_8000 |
|
||
| | CompressionDisabled : False |
|
||
| | Configuration : TDEV |
|
||
| | DeviceID : 0012F |
|
||
| | DeviceLabel : OS-d87edb98-60fd-49dd-bb0f-cc388cf6f3f4 |
|
||
| | Emulation : FBA |
|
||
| | ReplicationEnabled : False |
|
||
| | ServiceLevel : Diamond |
|
||
| | Workload : None |
|
||
| name | powermax-volume |
|
||
+--------------------------------+------------------------------------------------------------+
|
||
|
||
|
||
17. Unisphere High Availability (HA) support
|
||
--------------------------------------------
|
||
|
||
This feature facilitates high availability of Unisphere for PowerMax servers,
|
||
allowing for one or more backup unisphere instances in the event of a loss in
|
||
connection to the primary Unisphere instance. The PowerMax driver will
|
||
cycle through the list of failover instances, trying each until a successful
|
||
connection is made. The ordering is first in, first out (FIFO), so the first
|
||
``u4p_failover_target`` specified in ``cinder.conf`` will be the first
|
||
selected, the second ``u4p_failover_target`` in ``cinder.conf`` will be the
|
||
second selected, and so on until all failover targets are exhausted.
|
||
|
||
Requirements
|
||
~~~~~~~~~~~~
|
||
|
||
- All required instances of Unisphere for PowerMax are set up and configured
|
||
for the array(s)
|
||
- Array(s) are locally registered with the instance of Unisphere that will be
|
||
used as a failover instance. There are two failover types, local and
|
||
remote:
|
||
|
||
- `Local failover` - Primary Unisphere is unreachable, failover to
|
||
secondary local instance of Unisphere to resume normal operations at
|
||
primary site.
|
||
- `Remote failover` - Complete loss of primary site so primary instance of
|
||
Unisphere is unreachable, failover to secondary instance of Unisphere at
|
||
remote site to resume operations with the R2 array.
|
||
|
||
.. note::
|
||
|
||
Replication must be configured in advance for remote failover to work
|
||
successfully. Human intervention will also be required to failover from R1
|
||
array to R2 array in Cinder using ``cinder failover-host`` command
|
||
(see `Volume replication support`_ for replication setup details).
|
||
|
||
.. note::
|
||
|
||
The remote target array must be registered as local to the remote instance
|
||
of Unisphere
|
||
|
||
Configuration
|
||
~~~~~~~~~~~~~
|
||
|
||
The following configuration changes need to be made in ``cinder.conf`` under
|
||
the PowerMax backend stanza in order to support the failover to secondary
|
||
Unisphere. Cinder services will need to be restarted for changes to take
|
||
effect.
|
||
|
||
.. code-block:: console
|
||
|
||
[POWERMAX_1]
|
||
...
|
||
|
||
u4p_failover_timeout = 30
|
||
u4p_failover_retries = 3
|
||
u4p_failover_backoff_factor = 1
|
||
u4p_failover_autofailback = True
|
||
u4p_failover_target = san_ip:10.10.10.12,
|
||
san_api_port: 8443,
|
||
san_login:my_username,
|
||
san_password:my_password,
|
||
driver_ssl_cert_verify: False,
|
||
u4p_failover_target = san_ip:10.10.10.13,
|
||
san_api_port: 8443
|
||
san_login:my_username,
|
||
san_password:my_password,
|
||
driver_ssl_cert_verify: True,
|
||
driver_ssl_cert_path: /path/to/my_unisphere_host.pem
|
||
|
||
.. note::
|
||
|
||
``u4p_failover_target`` key value pairs will need to be on the same
|
||
line (separated by commas) in ``cinder.conf``. They are displayed on
|
||
separated lines above for readability.
|
||
|
||
.. note::
|
||
|
||
To add more than one Unisphere failover target create additional
|
||
``u4p_failover_target`` details for the Unisphere instance. These will be
|
||
cycled through in a first-in, first-out (FIFO) basis, the first failover
|
||
target in ``cinder.conf`` will be the first backup instance of Unisphere
|
||
used by the PowerMax driver.
|
||
|
||
|
||
18. Rapid TDEV deallocation
|
||
---------------------------
|
||
|
||
The PowerMax driver can now leverage the enhanced volume delete feature-set
|
||
made available in the PowerMax 5978 Foxtail uCode release. These enhancements
|
||
allow volume deallocation & deletion to be combined into a single call.
|
||
Previously, volume deallocation & deletion were split into separate tasks;
|
||
now a single REST call is dispatched and a response code on the projected
|
||
outcome of their request is issued rapidly allowing other task execution to
|
||
proceed without the delay. No additional configuration is necessary, the
|
||
system will automatically determine when to use either the rapid or legacy
|
||
compliant volume deletion sequence based on the connected PowerMax array’s
|
||
metadata.
|
||
|
||
|
||
19. PowerMax online (in-use) device expansion
|
||
---------------------------------------------
|
||
|
||
.. table::
|
||
|
||
+---------------------------------+-------------------------------------------+
|
||
| uCode Level | Supported In-Use Volume Extend Operations |
|
||
+----------------+----------------+--------------+--------------+-------------+
|
||
| R1 uCode Level | R2 uCode Level | Sync | Async | Metro |
|
||
+================+================+==============+==============+=============+
|
||
| 5978.711 | 5978.711 | Y | Y | Y |
|
||
+----------------+----------------+--------------+--------------+-------------+
|
||
| 5978.711 | 5978.669 | Y | Y | Y |
|
||
+----------------+----------------+--------------+--------------+-------------+
|
||
| 5978.711 | 5978.444 | Y | Y | Y |
|
||
+----------------+----------------+--------------+--------------+-------------+
|
||
| 5978.711 | 5978.221 | Y | Y | N |
|
||
+----------------+----------------+--------------+--------------+-------------+
|
||
| 5978.669 | 5978.669 | Y | Y | Y |
|
||
+----------------+----------------+--------------+--------------+-------------+
|
||
| 5978.669 | 5978.444 | Y | Y | Y |
|
||
+----------------+----------------+--------------+--------------+-------------+
|
||
| 5978.669 | 5978.221 | Y | Y | N |
|
||
+----------------+----------------+--------------+--------------+-------------+
|
||
| 5978.444 | 5978.444 | Y | Y | Y |
|
||
+----------------+----------------+--------------+--------------+-------------+
|
||
| 5978.444 | 5978.221 | Y | Y | N |
|
||
+----------------+----------------+--------------+--------------+-------------+
|
||
| 5978.221 | 5978.221 | Y | Y | N |
|
||
+----------------+----------------+--------------+--------------+-------------+
|
||
|
||
|
||
Assumptions, restrictions and prerequisites
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
- ODE in the context of this document refers to extending a volume where it
|
||
is in-use, that is, attached to an instance.
|
||
- The ``allow_extend`` is only applicable on VMAX-Hybrid_ arrays or All Flash
|
||
arrays with HyperMax OS. If included elsewhere, it is ignored.
|
||
- Where one array is a lower uCode than the other, the environment is limited
|
||
to functionality of that of the lowest uCode level, i.e. if R1 is 5978.444
|
||
and R2 is 5978.221, expanding a metro volume is not supported, both R1 and
|
||
R2 need to be on 5978.444 uCode at a minimum.
|
||
|
||
|
||
20. PowerMax array and storage group tagging
|
||
--------------------------------------------
|
||
|
||
Unisphere for PowerMax 9.1 and later supports tagging of storage groups and
|
||
arrays, so the user can give their own 'tag' for ease of searching and/or
|
||
grouping.
|
||
|
||
Assumptions, restrictions and prerequisites
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
- The storage group tag(s) is associated with a volume type extra spec key
|
||
``storagetype:storagegrouptags``.
|
||
- The array tag is associated with the backend stanza using key
|
||
``powermax_array_tag_list``. It expects a list of one or more comma
|
||
separated values, for example
|
||
``powermax_array_tag_list=[value1,value2, value3]``
|
||
- They can be one or more values in a comma separated list.
|
||
- There is a 64 characters limit of letters, numbers, - and _.
|
||
- 8 tags are allowed per storage group and array.
|
||
- Tags cannot be modified once a volume has been created with that volume
|
||
type. This is an OpenStack constraint.
|
||
- Tags can be modified on the backend stanza, but none will ever be removed,
|
||
only added.
|
||
- There is no restriction on creating or deleting tags of OpenStack storage
|
||
groups or arrays outside of OpenStack, for example Unisphere for PowerMax
|
||
UI. The max number of 8 tags will apply however, as this is a Unisphere for
|
||
PowerMax limit.
|
||
|
||
Set a storage group tag on a volume type:
|
||
|
||
.. code-block:: console
|
||
|
||
$ openstack volume type set --property storagetype:storagegrouptags=myStorageGroupTag1,myStorageGroupTag2
|
||
|
||
|
||
Set an array tag on the PowerMax backend:
|
||
|
||
.. code-block:: console
|
||
|
||
[POWERMAX_ISCSI]
|
||
volume_driver = cinder.volume.drivers.dell_emc.powermax.iscsi.PowerMaxISCSIDriver
|
||
volume_backend_name = POWERMAX_ISCSI
|
||
san_ip = 10.10.10.10
|
||
san_login = my_u4v_username
|
||
san_password = my_u4v_password
|
||
powermax_srp = SRP_1
|
||
powermax_array = 000123456789
|
||
powermax_port_groups = [OS-ISCSI-PG]
|
||
powermax_array_tag_list = [openstack1, openstack2]
|
||
|
||
|
||
21. PowerMax short host name and port group name override
|
||
---------------------------------------------------------
|
||
|
||
This functionality allows the user to customize the short host name and port
|
||
group name that are contained in the PowerMax driver storage groups and
|
||
masking views names. For current functionality please refer to
|
||
`PowerMax naming conventions`_ for more details.
|
||
|
||
As the storage group name and masking view name are limited to 64 characters
|
||
the short host name needs to be truncated to 16 characters or less and port
|
||
group needs to be truncated to 12 characters or less. This functionality
|
||
offers a little bit more flexibility to determine how these truncated
|
||
components should look.
|
||
|
||
.. note::
|
||
|
||
Once the port group and short host name have been overridden with any
|
||
new format, it is not possible to return to the default format or change
|
||
to another format if any volumes are in an attached state. This is because
|
||
there is no way to determine the overridden format once
|
||
``powermax_short_host_name_template` or ``powermax_port_group_name_template``
|
||
have been removed or changed.
|
||
|
||
Assumptions, restrictions, and prerequisites
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
- Backward compatibility with old format is preserved.
|
||
- ``cinder.conf`` will have 2 new configuration options,
|
||
``short_host_name_template`` and ``port_group_name_template``.
|
||
- If a storage group, masking view or initiator group in the old naming
|
||
convention already exists, this remains and any new attaches will use
|
||
the new naming convention where the label for the short host name
|
||
and/or port group has been customized by the user.
|
||
- Only the short host name and port group name components can be renamed
|
||
within the storage group, initiator group and masking view names.
|
||
- If the ``powermax_short_host_name_template`` and
|
||
``powermax_port_group_name_template`` do not adhere to the rules, then
|
||
the operation will fail early and gracefully with a clear description as
|
||
to the problem.
|
||
- The templates cannot be changed once volumes have been attached using the
|
||
new configuration.
|
||
- If only one of the templates are configured, then the other will revert to
|
||
the default option.
|
||
- The UUID is generated from the MD5 hash of the full short host name
|
||
and port group name
|
||
- If ``userdef`` is used, the onus is on the user to make sure it will be
|
||
unique among all short host names (controller and compute nodes) and
|
||
unique among port groups.
|
||
|
||
|
||
.. table:: Short host name templates
|
||
|
||
+-----------------------------------+-------------------------------------+------------------------------------+
|
||
| powermax_short_host_name_template | Description | Rule |
|
||
+===================================+=====================================+====================================+
|
||
| shortHostName | This is the default option | Existing functionality, if over 16 |
|
||
| | | characters then see |
|
||
| | | `PowerMax naming conventions`_, |
|
||
| | | otherwise short host name |
|
||
+-----------------------------------+-------------------------------------+------------------------------------+
|
||
| shortHostName[:x])uuid[:x] | First x characters of the short | Must be less than 16 characters |
|
||
| e.g. | host name and x uuid | |
|
||
| shortHostName[:6]uuid[:9] | characters created from md5 | |
|
||
| | hash of short host name | |
|
||
+-----------------------------------+-------------------------------------+------------------------------------+
|
||
| shortHostName[:x]userdef | First x characters of the short | Must be less than 16 characters |
|
||
| e.g. | host name and a user defined x char | |
|
||
| shortHostName[:6]-testHost | name. NB - the responsibility is on | |
|
||
| | the user for uniqueness | |
|
||
+-----------------------------------+-------------------------------------+------------------------------------+
|
||
| shortHostName[-x:]uuid[:x] | Last x characters of the short | Must be less than 16 characters |
|
||
| e.g. | host name and x uuid | |
|
||
| shortHostName[-6:]uuid[:9] | characters created from md5 | |
|
||
| | hash of short host name | |
|
||
+-----------------------------------+-------------------------------------+------------------------------------+
|
||
| shortHostName[-x:]userdef | Last x characters of the short | Must be less than 16 characters |
|
||
| e.g. | host name and a user defined x char | |
|
||
| shortHostName[-6:]-testHost | name. NB - the responsibility is on | |
|
||
| | the user for uniqueness | |
|
||
+-----------------------------------+-------------------------------------+------------------------------------+
|
||
|
||
|
||
.. table:: Port group name templates
|
||
|
||
+-----------------------------------+-------------------------------------+------------------------------------+
|
||
| powermax_port_group_name_template | Description | Rule |
|
||
+===================================+=====================================+====================================+
|
||
| portGroupName | This is the default option | Existing functionality, if over 12 |
|
||
| | | characters then see |
|
||
| | | `PowerMax naming conventions`_, |
|
||
| | | otherwise port group name |
|
||
+-----------------------------------+-------------------------------------+------------------------------------+
|
||
| portGroupName[:x])uuid[:x] | First x characters of the port | Must be less than 12 characters |
|
||
| e.g. | group name and x uuid | |
|
||
| portGroupName[:6]uuid[:5] | characters created from md5 | |
|
||
| | hash of port group name | |
|
||
+-----------------------------------+-------------------------------------+------------------------------------+
|
||
| portGroupName[:x]userdef | First x characters of the port | Must be less than 12 characters |
|
||
| e.g. | group name and a user defined x char| |
|
||
| portGroupName[:6]-test | name. NB - the responsibility is on | |
|
||
| | the user for uniqueness | |
|
||
+-----------------------------------+-------------------------------------+------------------------------------+
|
||
| portGroupName[-x:]uuid[:x] | Last x characters of the port | Must be less than 12 characters |
|
||
| e.g. | group name and x uuid | |
|
||
| portGroupName[-6:]uuid[:5] | characters created from md5 | |
|
||
| | hash of port group name | |
|
||
+-----------------------------------+-------------------------------------+------------------------------------+
|
||
| portGroupName[-x:]userdef | Last x characters of the port | Must be less than 12 characters |
|
||
| e.g. | group name and a user defined x char| |
|
||
| portGroupName[-6:]-test | name. NB - the responsibility is on | |
|
||
| | the user for uniqueness | |
|
||
+-----------------------------------+-------------------------------------+------------------------------------+
|
||
|
||
|
||
21. Snap ids replacing generations
|
||
----------------------------------
|
||
|
||
Snap ids were introduced to the PowerMax in microcde 5978.669.669 and
|
||
Unisphere for PowerMax 9.2. Generations existed previously and could cause
|
||
stale data if deleted out of sequence, even though we locked against this
|
||
occurence. This happened when the newer generation(s) inherited its deleted
|
||
predecessors generation number. So in a series of 0, 1, 2 and 3 generations,
|
||
if generation 1 gets deleted, generation 2 now becomes generation 1 and
|
||
generation 3 becomes generation 2 and so on down the line.
|
||
Snap ids are unique to each snapVX and will not change once assigned at
|
||
creation so out of sequence deletions are no longer an issue.
|
||
Generations will remain for arrays with microcode less than 5978.669.669.
|
||
|
||
|
||
Cinder supported operations
|
||
===========================
|
||
|
||
Volume replication support
|
||
--------------------------
|
||
|
||
|
||
.. note::
|
||
|
||
A mix of ``RDF1+TDEV`` and ``TDEV`` volumes should not exist in the same
|
||
storage group. This can happen on a cleanup operation after breaking the
|
||
pair and a 'TDEV' remains in the storage group on either the local or
|
||
remote array. If this happens, remove the volume from the storage
|
||
group so that further replicated volume operations can continue.
|
||
For example, Remove ``TDEV`` from ``OS-[SRP]-[SL]-[WL]-RA-SG``.
|
||
|
||
.. note::
|
||
|
||
Replication storage groups should exist on both local and remote array but
|
||
never on just one. For example, if OS-[SRP]-[SL]-[WL]-RA-SG exists on
|
||
local array A it must also exist on remote array B. If this condition
|
||
does not hold, further replication operations will fail. This applies
|
||
to management storage groups in the case of ``Asynchronous`` and ``Metro``
|
||
modes also. See :ref:`my-table`.
|
||
|
||
.. note::
|
||
|
||
The number of devices in replication storage groups in both local and
|
||
remote arrays should be same. This also applies to management storage
|
||
groups in ``Asynchronous`` and ``Metro`` modes. See :ref:`my-table`.
|
||
|
||
|
||
|
||
Configure a single replication target
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
#. Configure an SRDF group between the chosen source and target
|
||
arrays for the PowerMax Cinder driver to use. The source array must
|
||
correspond with the ``powermax_array`` entry in ``cinder.conf``.
|
||
#. Select both the director and the ports for the SRDF emulation to use on
|
||
both sides. Bear in mind that network topology is important when choosing
|
||
director endpoints. Supported modes are ``Synchronous``, ``Asynchronous``,
|
||
and ``Metro``.
|
||
|
||
.. note::
|
||
|
||
If the source and target arrays are not managed by the same Unisphere
|
||
server (that is, the target array is remotely connected to server -
|
||
for example, if you are using embedded management), in the event of a
|
||
full disaster scenario (i.e. the primary array is completely lost and
|
||
all connectivity to it is gone), the Unisphere server would no longer
|
||
be able to contact the target array. In this scenario, the volumes would
|
||
be automatically failed over to the target array, but administrator
|
||
intervention would be required to either; configure the target (remote)
|
||
array as local to the current Unisphere server (if it is a stand-alone
|
||
server), or enter the details of a second Unisphere server to the
|
||
``cinder.conf``, which is locally connected to the target array (for
|
||
example, the embedded management Unisphere server of the target array),
|
||
and restart the Cinder volume service.
|
||
|
||
.. note::
|
||
|
||
If you are setting up an SRDF/Metro configuration, it is recommended that
|
||
you configure a Witness or vWitness for bias management. Please see the
|
||
`SRDF Metro Overview & Best Practices`_ guide for more information.
|
||
|
||
.. note::
|
||
The PowerMax Cinder drivers do not support Cascaded SRDF.
|
||
|
||
.. note::
|
||
|
||
The transmit idle functionality must be disabled on the R2 array for
|
||
Asynchronous rdf groups. If this is not disabled it will prevent failover
|
||
promotion in the event of access to the R1 array being lost.
|
||
|
||
.. code-block:: console
|
||
|
||
# symrdf -sid <sid> -rdfg <rdfg> set rdfa -transmit_idle off
|
||
|
||
.. note::
|
||
|
||
When creating RDF enabled volumes, if there are existing volumes in the
|
||
target storage group, all rdf pairs related to that storage group must
|
||
have the same rdf state i.e. rdf pair states must be consistent across
|
||
all volumes in a storage group when attempting to create a new replication
|
||
enabled volume. If mixed rdf pair states are found during a volume creation
|
||
attempt, an error will be raised by the rdf state validation checks.
|
||
In this event, please wait until all volumes in the storage group have
|
||
reached a consistent state.
|
||
|
||
#. Enable replication in ``/etc/cinder/cinder.conf``.
|
||
To enable the replication functionality in PowerMax Cinder driver, it is
|
||
necessary to create a replication volume-type. The corresponding
|
||
back-end stanza in ``cinder.conf`` for this volume-type must then
|
||
include a ``replication_device`` parameter. This parameter defines a
|
||
single replication target array and takes the form of a list of key
|
||
value pairs.
|
||
|
||
.. code-block:: console
|
||
|
||
enabled_backends = POWERMAX_FC_REPLICATION
|
||
[POWERMAX_FC_REPLICATION]
|
||
volume_driver = cinder.volume.drivers.dell_emc.powermax.fc.PowerMaxFCDriver
|
||
san_ip = 10.10.10.10
|
||
san_login = my_u4v_username
|
||
san_password = my_u4v_password
|
||
powermax_srp = SRP_1
|
||
powermax_array = 000123456789
|
||
powermax_port_groups = [OS-FC-PG]
|
||
volume_backend_name = POWERMAX_FC_REPLICATION
|
||
replication_device = target_device_id:000197811111,
|
||
remote_port_group:os-failover-pg,
|
||
remote_pool:SRP_1,
|
||
rdf_group_label: 28_11_07,
|
||
mode:Metro,
|
||
metro_use_bias:False,
|
||
sync_interval:3,
|
||
sync_retries:200
|
||
|
||
.. note::
|
||
``replication_device`` key value pairs will need to be on the same
|
||
line (separated by commas) in ``cinder.conf``. They are displayed here on
|
||
separate lines above for improved readability.
|
||
|
||
* ``target_device_id`` The unique PowerMax array serial number of the
|
||
target array. For full failover functionality, the source and target
|
||
PowerMax arrays must be discovered and managed by the same U4V server.
|
||
|
||
* ``remote_port_group`` The name of a PowerMax port group that has been
|
||
pre-configured to expose volumes managed by this backend in the event
|
||
of a failover. Make sure that this port group contains either all FC or
|
||
all iSCSI port groups (for a given back end), as appropriate for the
|
||
configured driver (iSCSI or FC).
|
||
|
||
* ``remote_pool`` The unique pool name for the given target array.
|
||
|
||
* ``rdf_group_label`` The name of a PowerMax SRDF group that has been
|
||
pre-configured between the source and target arrays.
|
||
|
||
* ``mode`` The SRDF replication mode. Options are ``Synchronous``,
|
||
``Asynchronous``, and ``Metro``. This defaults to ``Synchronous`` if not
|
||
set.
|
||
|
||
* ``metro_use_bias`` Flag to indicate if 'bias' protection should be
|
||
used instead of Witness. This defaults to False.
|
||
|
||
* ``sync_interval`` How long in seconds to wait between intervals for SRDF
|
||
sync checks during Cinder PowerMax SRDF operations. Default is 3 seconds.
|
||
|
||
* ``sync_retries`` How many times to retry RDF sync checks during Cinder
|
||
PowerMax SRDF operations. Default is 200 retries.
|
||
|
||
* ``allow_extend`` Only applicable to VMAX-Hybrid_ arrays or All Flash
|
||
arrays running HyperMax OS (5977). It is a flag for
|
||
allowing the extension of replicated volumes. To extend a volume in
|
||
an SRDF relationship, this relationship must first be broken, the R1
|
||
device extended, and a new device pair established. If not explicitly set,
|
||
this flag defaults to ``False``.
|
||
|
||
.. note::
|
||
|
||
As the SRDF link must be severed, due caution should be exercised when
|
||
performing this operation. If absolutely necessary, only one source and
|
||
target pair should be extended at a time (only only applicable to
|
||
VMAX-Hybrid_ arrays or All Flash arrays with HyperMax OS).
|
||
|
||
|
||
#. Create a ``replication-enabled`` volume type. Once the
|
||
``replication_device`` parameter has been entered in the PowerMax
|
||
backend entry in the ``cinder.conf``, a corresponding volume type
|
||
needs to be created ``replication_enabled`` property set. See
|
||
above `Create volume types`_ for details.
|
||
|
||
.. code-block:: console
|
||
|
||
# openstack volume type set --property replication_enabled="<is> True" \
|
||
POWERMAX_FC_REPLICATION
|
||
|
||
.. note::
|
||
Service Level and Workload: An attempt will be made to create a storage
|
||
group on the target array with the same service level and workload
|
||
combination as the primary. However, if this combination is unavailable
|
||
on the target (for example, in a situation where the source array is a
|
||
VMAX-Hybrid_, the target array is an All Flash, and an All
|
||
Flash incompatible service level like Bronze is configured), no service
|
||
level will be applied.
|
||
|
||
Configure multiple replication targets
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
Setting multiple replication devices in cinder.conf allows the use of all the
|
||
supported replication modes simultaneously. Up to three replication devices
|
||
can be set, one for each of the replication modes available. An additional
|
||
volume type ``extra spec`` (``storagetype:replication_device_backend_id``) is
|
||
then used to determine which replication device should be utilized when
|
||
attempting to perform an operation on a volume which is replication enabled.
|
||
All details, guidelines and recommendations set out in the
|
||
`Configure a single replication target`_ section also apply in a multiple
|
||
replication device scenario.
|
||
|
||
Multiple replication targets limitations and restrictions:
|
||
#. There can only be one of each replication mode present across all of the
|
||
replication devices set in ``cinder.conf``.
|
||
#. Details for ``target_device_id``, ``remote_port_group`` and
|
||
``remote_pool`` should be identical across replication devices.
|
||
#. The ``backend_id`` and ``rdf_group_label`` values must be unique across
|
||
all replication devices.
|
||
|
||
Adding additional ``replication_device`` to cinder.conf:
|
||
#. Open ``cinder.conf`` for editing
|
||
#. If a replication device is already present, add the ``backend_id`` key
|
||
with a value of ``backend_id_legacy_rep``. If this key is already
|
||
defined, it's value must be updated to ``backend_id_legacy_rep``.
|
||
#. Add the additional replication devices to the backend stanza. Any
|
||
additional replication devices must have a ``backend_id`` key set. The
|
||
value of these must ``not`` be ``backend_id_legacy_rep``.
|
||
|
||
Example existing backend stanza pre-multiple replication:
|
||
|
||
.. code-block:: console
|
||
|
||
enabled_backends = POWERMAX_FC_REPLICATION
|
||
|
||
[POWERMAX_FC_REPLICATION]
|
||
volume_driver = cinder.volume.drivers.dell_emc.powermax.fc.PowerMaxFCDriver
|
||
san_ip = 10.10.10.10
|
||
san_login = my_u4v_username
|
||
san_password = my_u4v_password
|
||
powermax_srp = SRP_1
|
||
powermax_array = 000123456789
|
||
powermax_port_groups = [OS-FC-PG]
|
||
volume_backend_name = POWERMAX_FC_REPLICATION
|
||
replication_device = backend_id:id,
|
||
target_device_id:000197811111,
|
||
remote_port_group:os-failover-pg,
|
||
remote_pool:SRP_1,
|
||
rdf_group_label: 28_11_07,
|
||
mode:Metro,
|
||
metro_use_bias:False,
|
||
sync_interval:3,
|
||
sync_retries:200
|
||
|
||
Example updated backend stanza:
|
||
|
||
.. code-block:: console
|
||
|
||
enabled_backends = POWERMAX_FC_REPLICATION
|
||
|
||
[POWERMAX_FC_REPLICATION]
|
||
volume_driver = cinder.volume.drivers.dell_emc.powermax.fc.PowerMaxFCDriver
|
||
san_ip = 10.10.10.10
|
||
san_login = my_u4v_username
|
||
san_password = my_u4v_password
|
||
powermax_srp = SRP_1
|
||
powermax_array = 000123456789
|
||
powermax_port_groups = [OS-FC-PG]
|
||
volume_backend_name = POWERMAX_FC_REPLICATION
|
||
replication_device = backend_id:backend_id_legacy_rep
|
||
target_device_id:000197811111,
|
||
remote_port_group:os-failover-pg,
|
||
remote_pool:SRP_1,
|
||
rdf_group_label: 28_11_07,
|
||
mode:Metro,
|
||
metro_use_bias:False,
|
||
sync_interval:3,
|
||
sync_retries:200
|
||
replication_device = backend_id:sync-rep-id
|
||
target_device_id:000197811111,
|
||
remote_port_group:os-failover-pg,
|
||
remote_pool:SRP_1,
|
||
rdf_group_label: 29_12_08,
|
||
mode:Synchronous,
|
||
sync_interval:3,
|
||
sync_retries:200
|
||
replication_device = backend_id:async-rep-id
|
||
target_device_id:000197811111,
|
||
remote_port_group:os-failover-pg,
|
||
remote_pool:SRP_1,
|
||
rdf_group_label: 30_13_09,
|
||
mode:Asynchronous,
|
||
sync_interval:3,
|
||
sync_retries:200
|
||
|
||
.. note::
|
||
|
||
For environments without existing replication devices. The
|
||
``backend_id`` values can be set to any value for all replication devices.
|
||
The ``backend_id_legacy_rep`` value is only needed when updating a legacy
|
||
system with an existing replication device to use multiple replication
|
||
devices.
|
||
|
||
The additional replication devices defined in ``cinder.conf`` will be detected
|
||
after restarting the cinder volume service.
|
||
|
||
To specify which ``replication_device`` a volume type should use an additional
|
||
property named ``storagetype:replication_device_backend_id`` must be added to
|
||
the extra specs of the volume type. The id value assigned to the
|
||
``storagetype:replication_device_backend_id`` key in the volume type must
|
||
match the ``backend_id`` assigned to the ``replication_device`` in
|
||
``cinder.conf``.
|
||
|
||
.. code-block:: console
|
||
|
||
# openstack volume type set \
|
||
--property storagetype:replication_device_backend_id="<id>" \
|
||
<VOLUME_TYPE>
|
||
|
||
.. note::
|
||
|
||
Specifying which replication device to use is done in addition to the
|
||
basic replication setup for a volume type seen in
|
||
`Configure a single replication target`_
|
||
|
||
.. note::
|
||
|
||
In a legacy system where volume types are present that were replication
|
||
enabled before adding multiple replication devices, the
|
||
``storagetype:replication_device_backend_id`` should be omitted from any
|
||
volume type that does/will use the legacy ``replication_device`` i.e.
|
||
when ``storagetype:replication_device_backend_id`` is omitted the
|
||
replication_device with a ``backend_id`` of ``backend_id_legacy_rep``
|
||
will be used.
|
||
|
||
Volume replication interoperability with other features
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
Most features are supported, except for the following:
|
||
|
||
* Replication Group operations are available for volumes in Synchronous mode
|
||
only.
|
||
|
||
* The Ussuri release of OpenStack supports retyping in-use volumes to and from
|
||
replication enabled volume types with limited exception of volumes with
|
||
Metro replication enabled. To retype to a volume-type that is Metro enabled
|
||
the volume **must** first be detached then retyped. The reason for this is
|
||
so the paths from the Nova instance to the Metro R1 & R2 volumes must be
|
||
initialised, this is not possible on the R2 device whilst a volume is
|
||
attached.
|
||
|
||
* The image volume cache functionality is supported (enabled by setting
|
||
``image_volume_cache_enabled = True``), but one of two actions must be taken
|
||
when creating the cached volume:
|
||
|
||
* The first boot volume created on a backend (which will trigger the
|
||
cached volume to be created) should be the smallest necessary size.
|
||
For example, if the minimum size disk to hold an image is 5GB, create
|
||
the first boot volume as 5GB. All subsequent boot volumes are extended
|
||
to the user specific size.
|
||
* Alternatively, ensure that the ``allow_extend`` option in the
|
||
``replication_device parameter`` is set to ``True``. This is only
|
||
applicable to VMAX-Hybrid_ arrays or All Flash array with HyperMax OS.
|
||
|
||
|
||
Failover host
|
||
~~~~~~~~~~~~~
|
||
|
||
.. note::
|
||
|
||
Failover and failback operations are not applicable in Metro
|
||
configurations.
|
||
|
||
In the event of a disaster, or where there is required downtime, upgrade
|
||
of the primary array for example, the administrator can issue the failover
|
||
host command to failover to the configured target:
|
||
|
||
.. code-block:: console
|
||
|
||
# cinder failover-host cinder_host@POWERMAX_FC_REPLICATION
|
||
|
||
After issuing ``cinder failover-host`` Cinder will set the R2 array as the
|
||
target array for Cinder, however, to get existing instances to use this new
|
||
array and paths to volumes it is necessary to first shelve Nova instances and
|
||
then unshelve them, this will effectively restart the Nova instance and
|
||
re-establish data paths between Nova instances and the volumes on the R2 array.
|
||
|
||
.. code-block:: console
|
||
|
||
# nova shelve <server>
|
||
# nova unshelve [--availability-zone <availability_zone>] <server>
|
||
|
||
When a host is in failover mode performing normal volume or snapshot
|
||
provisioning will not be possible, failover host mode simply provides access
|
||
to replicated volumes to minimise environment down-time. The primary objective
|
||
whilst in failover mode should be to get the R1 array back online. When the
|
||
primary array becomes available again, you can initiate a fail-back using the
|
||
same failover command and specifying ``--backend_id default``:
|
||
|
||
.. code-block:: console
|
||
|
||
# cinder failover-host cinder_host@POWERMAX_FC_REPLICATION --backend_id default
|
||
|
||
After issuing the failover command to revert to the default backend host it is
|
||
necessary to re-issue the Nova shelve and unshelve commands to restore the
|
||
data paths between Nova instances and their corresponding back end volumes.
|
||
Once reverted to the default backend volume and snapshot provisioning
|
||
operations can continue as normal.
|
||
|
||
Failover promotion
|
||
~~~~~~~~~~~~~~~~~~
|
||
|
||
Failover promotion can be used to transfer all existing RDF enabled volumes
|
||
to the R2 array and overwrite any references to the original R1 array. This
|
||
can be used in the event of total R1 array failure or in other cases where
|
||
an array transfer is warranted. If the R1 array is online and working and the
|
||
RDF links are still enabled the failover promotion will automatically delete
|
||
rdf pairs as necessary. If the R1 array or the link to the R1 array is down,
|
||
a half deletepair must be issued manually for those volumes during the
|
||
failover promotion.
|
||
|
||
1. Issue failover command:
|
||
|
||
.. code-block:: console
|
||
|
||
# cinder failover-host <host>
|
||
|
||
2. Enable array promotion:
|
||
|
||
.. code-block:: console
|
||
|
||
# cinder failover-host --backend_id=pmax_failover_start_array_promotion <host>
|
||
|
||
3. View and re-enable the cinder service
|
||
|
||
.. code-block:: console
|
||
|
||
# cinder service-list
|
||
# cinder service-enable <host> <binary>
|
||
|
||
4. Remove all volumes from volume groups
|
||
|
||
.. code-block:: console
|
||
|
||
# cinder --os-volume-api-version 3.13 group-update --remove-volumes <Vol1ID, etc..> <volume_group_name>
|
||
|
||
5. Detach all volumes that are attached to instances
|
||
|
||
.. code-block:: console
|
||
|
||
# openstack server remove volume <instance_id> <volume_id>
|
||
|
||
.. note::
|
||
|
||
Deleting the instance will call a detach volume for each attached volume.
|
||
A terminate connection can be issued manually using the following command
|
||
for volumes that are stuck in the attached state without an instance.
|
||
|
||
.. code-block:: console
|
||
|
||
# cinder --os-volume-api-version 3.50 attachment-delete <attachment_id>
|
||
|
||
6. Delete all remaining instances
|
||
|
||
.. code-block:: console
|
||
|
||
# nova delete <instance_id>
|
||
|
||
7. Create new volume types
|
||
|
||
New volume types must be created with references to the remote array. All new
|
||
volume types must adhere to the following guidelines:
|
||
|
||
.. code-block:: text
|
||
|
||
1. Uses the same workload, SLO & compression setting as the previous R1 volume type.
|
||
2. Uses the remote array instead of the primary for its pool name.
|
||
3. Uses the same volume_backend_name as the previous volume type.
|
||
4. Must not have replication enabled.
|
||
|
||
Example existing volume type extra specs.
|
||
|
||
.. code-block:: text
|
||
|
||
pool_name='Gold+None+SRP_1+000297900330', replication_enabled='<is> True',
|
||
storagetype:replication_device_backend_id='async-rep-1', volume_backend_name='POWERMAX_ISCSI_NONE'
|
||
|
||
Example new volume type extra specs.
|
||
|
||
.. code-block:: text
|
||
|
||
pool_name='Gold+None+SRP_1+000197900049', volume_backend_name='POWERMAX_ISCSI_NONE'
|
||
|
||
8. Retype volumes to new volume types
|
||
|
||
Additional checks will be performed during failover promotion retype to ensure
|
||
workload, compression and slo settings meet the criteria specified above when
|
||
creating the new volume types.
|
||
|
||
.. code-block:: console
|
||
|
||
# cinder retype --migration-policy on-demand <volume> <volume_type>
|
||
|
||
.. note::
|
||
|
||
If the volumes RDF links are offline during this retype then a half deletepair
|
||
must be performed manually after retype. Please reference section 8.a. below
|
||
for guidance on this process.
|
||
|
||
8.a. Retype and RDF half deletepair
|
||
|
||
In instances where the rdf links are offline and rdf pairs have been set to
|
||
partitioned state there are additional requirements. In that scenario the
|
||
following order should be adhered to:
|
||
|
||
.. code-block:: text
|
||
|
||
1. Retype all Synchronous volumes.
|
||
2. Half_deletepair all Synchronous volumes using the default storage group.
|
||
3. Retype all Asynchronous volumes.
|
||
4. Half_deletepair all Asynchronous volumes using their management storage group.
|
||
5. Retype all Metro volumes.
|
||
6. Half_deletepair all Metro volumes using their management storage group.
|
||
7. Delete the Asynchronous and Metro management storage groups.
|
||
|
||
.. note::
|
||
|
||
A half deletepair cannot be performed on Metro enabled volumes unless the
|
||
symforce option has been enabled in the symapi options. In symapi/config/options
|
||
uncomment and set 'SYMAPI_ALLOW_RDF_SYMFORCE = True'.
|
||
|
||
.. code-block:: console
|
||
|
||
# symrdf -sid <sid> -sg <sg> -rdfg <rdfg> -force -symforce half_deletepair
|
||
|
||
9. Issue failback
|
||
|
||
Issuing the failback command will disable both the failover and promotion
|
||
flags. Please ensure all volumes have been retyped and all replication pairs
|
||
have been deleted before issuing this command.
|
||
|
||
.. code-block:: console
|
||
|
||
# cinder failover-host --backend_id default <host>
|
||
|
||
10. Update cinder.conf
|
||
|
||
Update the cinder.conf file to include details for the new primary array. For
|
||
more information please see the Configure block storage in cinder.conf section
|
||
of this documentation.
|
||
|
||
11. Restart the cinder services
|
||
|
||
Restart the cinder volume service to allow it to detect the changes made to
|
||
the cinder.conf file.
|
||
|
||
12. Set Metro volumes to ready state
|
||
|
||
Metro volumes will be set to a Not Ready state after performing rdf pair
|
||
cleanup. Set these volumes back to Ready state to allow them to be attached
|
||
to instances. The U4P instance must be restarted for this change to be
|
||
detected.
|
||
|
||
.. code-block:: console
|
||
|
||
# symdev -sid <sid> ready -devs <dev_id1, dev_id2>
|
||
|
||
Asynchronous and metro replication management groups
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
Asynchronous and metro volumes in an RDF session, i.e. belonging to an SRDF
|
||
group, must be managed together for RDF operations (although there is a
|
||
``consistency exempt`` option for creating and deleting pairs in an Async
|
||
group). To facilitate this management, we create an internal RDF management
|
||
storage group on the backend. This RDF management storage group will use the
|
||
following naming convention:
|
||
|
||
.. code-block:: text
|
||
|
||
OS-[rdf_group_label]-[replication_mode]-rdf-sg
|
||
|
||
It is crucial for correct management that the volumes in this storage group
|
||
directly correspond to the volumes in the RDF group. For this reason, it is
|
||
imperative that the RDF group specified in the ``cinder.conf`` is for the
|
||
exclusive use by this Cinder backend. If there are any issues with the state
|
||
of your RDF enabled volumes prior to performing additional operations in Cinder
|
||
you will be notified in the Cinder volume logs.
|
||
|
||
|
||
Metro support
|
||
~~~~~~~~~~~~~
|
||
|
||
SRDF/Metro is a high availability solution. It works by masking both sides of
|
||
the RDF relationship to the host, and presenting all paths to the host,
|
||
appearing that they all point to the one device. In order to do this,
|
||
there needs to be multi-path software running to manage writing to the
|
||
multiple paths.
|
||
|
||
.. note::
|
||
|
||
The metro issue around formatting volumes when they are added to existing
|
||
metro RDF groups has been fixed in Unisphere for PowerMax 9.1, however, it
|
||
has only been addressed on arrays with PowerMax OS and will not be
|
||
available on arrays running a HyperMax OS.
|
||
|
||
|
||
Volume retype - storage assisted volume migration
|
||
--------------------------------------------------
|
||
|
||
Volume retype with storage assisted migration is supported now for
|
||
PowerMax arrays. Cinder requires that for storage assisted migration, a
|
||
volume cannot be retyped across backends. For using storage assisted volume
|
||
retype, follow these steps:
|
||
|
||
.. note::
|
||
|
||
From the Ussuri release of OpenStack the PowerMax driver supports retyping
|
||
in-use volumes to and from replication enabled volume types with limited
|
||
exception of volumes with Metro replication enabled. To retype to a
|
||
volume-type that is Metro enabled the volume **must** first be detached
|
||
then retyped. The reason for this is so the paths from the instance to the
|
||
Metro R1 & R2 volumes must be initialised, this is not possible on the R2
|
||
device whilst a volume is attached.
|
||
|
||
.. note::
|
||
|
||
When multiple replication devices are configured. If retyping from one
|
||
replication mode to another the R1 device ID is preserved and a new
|
||
R2 side device is created. As a result, the device ID on the R2 array
|
||
may be different after the retype operation has completed.
|
||
|
||
.. note::
|
||
|
||
Retyping an in-use volume to a metro enabled volume type is not currently
|
||
supported via storage-assisted migration. This retype can still be
|
||
performed using host-assisted migration by setting the migration-policy
|
||
to ``on-demand``.
|
||
|
||
.. code-block:: console
|
||
|
||
cinder retype --migration-policy on-demand <volume> <volume-type>
|
||
|
||
#. For migrating a volume from one Service Level or Workload combination to
|
||
another, use volume retype with the migration-policy to on-demand. The
|
||
target volume type should have the same volume_backend_name configured and
|
||
should have the desired pool_name to which you are trying to retype to
|
||
(please refer to `Create volume types`_ for details).
|
||
|
||
.. code-block:: console
|
||
|
||
$ cinder retype --migration-policy on-demand <volume> <volume-type>
|
||
|
||
|
||
Generic volume group support
|
||
----------------------------
|
||
|
||
Generic volume group operations are performed through the CLI using API
|
||
version 3.1x of the Cinder API. Generic volume groups are multi-purpose
|
||
groups which can be used for various features. The PowerMax driver supports
|
||
consistent group snapshots and replication groups. Consistent group
|
||
snapshots allows the user to take group snapshots which are consistent based
|
||
on the group specs. Replication groups allow for tenant facing APIs to enable
|
||
and disable replication, and to failover and failback, a group of volumes.
|
||
Generic volume groups have replaced the deprecated consistency groups.
|
||
|
||
Consistent group snapshot
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
To create a consistent group snapshot, set a group-spec, having the key
|
||
``consistent_group_snapshot_enabled`` set to ``<is> True`` on the group.
|
||
|
||
.. code-block:: console
|
||
|
||
# cinder --os-volume-api-version 3.11 group-type-key GROUP_TYPE set consistent_group_snapshot_enabled="<is> True"
|
||
|
||
Similarly the same key should be set on any volume type which is specified
|
||
while creating the group.
|
||
|
||
.. code-block:: console
|
||
|
||
# openstack volume type set --property consistent_group_snapshot_enabled="<is> True" POWERMAX_GROUP
|
||
|
||
If this key is not set on the group-spec or volume type, then the generic
|
||
volume group will be created/managed by Cinder (not the PowerMax driver).
|
||
|
||
.. note::
|
||
|
||
The consistent group snapshot should not be confused with the PowerMax
|
||
consistency group which is an SRDF construct.
|
||
|
||
Replication groups
|
||
~~~~~~~~~~~~~~~~~~
|
||
|
||
As with Consistent group snapshot ``consistent_group_snapshot_enabled`` should
|
||
be set to true on the group and the volume type for replication groups.
|
||
Only Synchronous replication is supported for use with Replication Groups.
|
||
When a volume is created into a replication group, replication is on by
|
||
default. The ``disable_replication`` api suspends I/O traffic on the devices,
|
||
but does NOT remove replication for the group. The ``enable_replication`` api
|
||
resumes I/O traffic on the RDF links. The ``failover_group`` api allows a group
|
||
to be failed over and back without failing over the entire host. See below for
|
||
usage.
|
||
|
||
.. note::
|
||
|
||
A generic volume group can be both consistent group snapshot enabled and
|
||
consistent group replication enabled.
|
||
|
||
Storage group names
|
||
~~~~~~~~~~~~~~~~~~~
|
||
|
||
Storage groups are created on the PowerMax as a result of creation of generic
|
||
volume groups. These storage groups follow a different naming convention
|
||
and are of the following format depending upon whether the groups have a
|
||
name.
|
||
|
||
.. code-block:: text
|
||
|
||
TruncatedGroupName_GroupUUID or GroupUUID
|
||
|
||
Group type, group, and group snapshot operations
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
Please refer to the official OpenStack `block-storage groups`_ documentation
|
||
for the most up to date group operations
|
||
|
||
Group replication operations
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
Generic volume group operations no longer require the user to specify the
|
||
Cinder CLI version, however, performing generic volume group replication
|
||
operations still require this setting. When running generic volume group
|
||
commands set the value ``--os-volume-api-version`` to ``3.38``. These
|
||
commands are not listed in the latest Cinder CLI documentation so will
|
||
remain here until added to the latest Cinder CLI version or deprecated
|
||
from Cinder.
|
||
|
||
|
||
- Enable group replication
|
||
|
||
.. code-block:: console
|
||
|
||
cinder --os-volume-api-version 3.38 group-enable-replication GROUP
|
||
|
||
- Disable group replication
|
||
|
||
.. code-block:: console
|
||
|
||
cinder --os-volume-api-version 3.38 group-disable-replication GROUP
|
||
|
||
- Failover group
|
||
|
||
.. code-block:: console
|
||
|
||
cinder --os-volume-api-version 3.38 group-failover-replication GROUP
|
||
|
||
- Failback group
|
||
|
||
.. code-block:: console
|
||
|
||
cinder --os-volume-api-version 3.38 group-failover-replication GROUP /
|
||
--secondary-backend-id default
|
||
|
||
|
||
Manage and unmanage Volumes
|
||
---------------------------
|
||
|
||
Managing volumes in OpenStack is the process whereby a volume which exists
|
||
on the storage device is imported into OpenStack to be made available for use
|
||
in the OpenStack environment. For a volume to be valid for managing into
|
||
OpenStack, the following prerequisites must be met:
|
||
|
||
- The volume exists in a Cinder managed pool
|
||
|
||
- The volume is not part of a Masking View
|
||
|
||
- The volume is not part of an SRDF relationship
|
||
|
||
- The volume is configured as a TDEV (thin device)
|
||
|
||
- The volume is set to FBA emulation
|
||
|
||
- The volume must a whole GB e.g. 5.5GB is not a valid size
|
||
|
||
- The volume cannot be a SnapVX target
|
||
|
||
|
||
For a volume to exist in a Cinder managed pool, it must reside in the same
|
||
Storage Resource Pool (SRP) as the backend which is configured for use in
|
||
OpenStack. Specifying the pool correctly can be entered manually as it follows
|
||
the same format:
|
||
|
||
.. code-block:: console
|
||
|
||
Pool format: <service_level>+<srp>+<array_id>
|
||
Pool example: Diamond+SRP_1+111111111111
|
||
|
||
|
||
.. list-table:: Pool values
|
||
:header-rows: 1
|
||
|
||
* - Key
|
||
- Value
|
||
* - ``service_level``
|
||
- The service level of the volume to be managed
|
||
* - ``srp``
|
||
- The Storage Resource Pool configured for use by the backend
|
||
* - ``array_id``
|
||
- The PowerMax serial number (12 digit numerical)
|
||
|
||
|
||
Manage volumes
|
||
~~~~~~~~~~~~~~
|
||
|
||
With your pool name defined you can now manage the volume into OpenStack, this
|
||
is possible with the CLI command ``cinder manage``. The ``bootable`` parameter
|
||
is optional in the command, if the volume to be managed into OpenStack is not
|
||
bootable leave this parameter out. OpenStack will also determine the size of
|
||
the value when it is managed so there is no need to specify the volume size.
|
||
|
||
Command format:
|
||
|
||
.. code-block:: console
|
||
|
||
$ cinder manage --name <new_volume_name> --volume-type <powermax_vol_type> \
|
||
--availability-zone <av_zone> <--bootable> <host> <identifier>
|
||
|
||
Command Example:
|
||
|
||
.. code-block:: console
|
||
|
||
$ cinder manage --name powermax_managed_volume --volume-type POWERMAX_ISCSI_DIAMOND \
|
||
--availability-zone nova demo@POWERMAX_ISCSI_DIAMOND#Diamond+SRP_1+111111111111 031D8
|
||
|
||
After the above command has been run, the volume will be available for use in
|
||
the same way as any other OpenStack PowerMax volume.
|
||
|
||
.. note::
|
||
|
||
An unmanaged volume with a prefix of ``OS-`` in its identifier name cannot
|
||
be managed into OpenStack, as this is a reserved keyword for managed
|
||
volumes. If the identifier name has this prefix, an exception will be thrown
|
||
by the PowerMax driver on a manage operation.
|
||
|
||
|
||
Managing volumes with replication enabled
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
Whilst it is not possible to manage volumes into OpenStack that are part of a
|
||
SRDF relationship, it is possible to manage a volume into OpenStack and
|
||
enable replication at the same time. This is done by having a replication
|
||
enabled PowerMax volume type (for more information see section Volume
|
||
Replication) during the manage volume process you specify the replication
|
||
volume type as the chosen volume type. Once managed, replication will be
|
||
enabled for that volume.
|
||
|
||
.. note::
|
||
|
||
It is not possible to manage into OpenStack SnapVX linked target volumes,
|
||
only volumes which are a SnapVX source are permitted. We do not want a
|
||
scenario where a snapshot source can exist outside of OpenStack management.
|
||
|
||
|
||
Unmanage volume
|
||
~~~~~~~~~~~~~~~
|
||
|
||
Unmanaging a volume is not the same as deleting a volume. When a volume is
|
||
deleted from OpenStack, it is also deleted from the PowerMax at the same time.
|
||
Unmanaging a volume is the process whereby a volume is removed from OpenStack
|
||
but it remains for further use on the PowerMax. The volume can also be managed
|
||
back into OpenStack at a later date using the process discussed in the
|
||
previous section. Unmanaging volume is carried out using the Cinder unmanage
|
||
CLI command:
|
||
|
||
Command format:
|
||
|
||
.. code-block:: console
|
||
|
||
$ cinder unmanage <volume_name/volume_id>
|
||
|
||
Command example:
|
||
|
||
.. code-block:: console
|
||
|
||
$ cinder unmanage powermax_test_vol
|
||
|
||
Once unmanaged from OpenStack, the volume can still be retrieved using its
|
||
device ID or OpenStack volume ID. Within Unisphere you will also notice that
|
||
the ``OS-`` prefix has been removed, this is another visual indication that
|
||
the volume is no longer managed by OpenStack.
|
||
|
||
|
||
Manage/unmanage snapshots
|
||
-------------------------
|
||
|
||
Users can manage PowerMax SnapVX snapshots into OpenStack if the source volume
|
||
already exists in Cinder. Similarly, users will be able to unmanage OpenStack
|
||
snapshots to remove them from Cinder but keep them on the storage backend.
|
||
|
||
Set-up, restrictions and requirements:
|
||
|
||
#. No additional settings or configuration is required to support this
|
||
functionality.
|
||
|
||
#. Manage/Unmanage snapshots requires SnapVX functionality support on PowerMax.
|
||
|
||
#. Manage/Unmanage Snapshots in OpenStack Cinder is only supported at present
|
||
through Cinder CLI commands.
|
||
|
||
#. It is only possible to manage or unmanage one snapshot at a time in Cinder.
|
||
|
||
Manage SnapVX snapshot
|
||
~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
It is possible to manage PowerMax SnapVX snapshots into OpenStack, where the
|
||
source volume from which the snapshot is taken already exists in, and is
|
||
managed by OpenStack Cinder. The source volume may have been created in
|
||
OpenStack Cinder, or it may have been managed in to OpenStack Cinder also.
|
||
With the support of managing SnapVX snapshots included in OpenStack Queens,
|
||
the restriction around managing SnapVX source volumes has been removed.
|
||
|
||
.. note::
|
||
|
||
It is not possible to manage into OpenStack SnapVX linked target volumes,
|
||
only volumes which are a SnapVX source are permitted. We do not want a
|
||
scenario where a snapshot source can exist outside of OpenStack management.
|
||
|
||
|
||
Requirements/restrictions:
|
||
|
||
#. The SnapVX source volume must be present in and managed by Cinder.
|
||
|
||
#. The SnapVX snapshot name must not begin with ``OS-``.
|
||
|
||
#. The SnapVX snapshot source volume must not be in a failed-over state.
|
||
|
||
#. Managing a SnapVX snapshot will only be allowed if the snapshot has no
|
||
linked target volumes.
|
||
|
||
|
||
Command structure:
|
||
|
||
#. Identify your SnapVX snapshot for management on the PowerMax, note the name.
|
||
|
||
#. Ensure the source volume is already managed into OpenStack Cinder, note
|
||
the device ID.
|
||
|
||
#. Using the Cinder CLI, use the following command structure to manage a
|
||
Snapshot into OpenStack Cinder:
|
||
|
||
|
||
.. code-block:: console
|
||
|
||
$ cinder snapshot-manage --id-type source-name
|
||
[--name <name>]
|
||
[--description <description>]
|
||
[--metadata [<key=value> [<key=value> ...]]]
|
||
<volume name/id> <identifier>
|
||
|
||
Positional arguments:
|
||
|
||
- ``<volume name/id>`` Source OpenStack volume name
|
||
|
||
- ``<identifier>`` Name of existing snapshot on PowerMax backend
|
||
|
||
Optional arguments:
|
||
|
||
- ``--name <name>`` Snapshot name (Default=``None``)
|
||
|
||
- ``--description <description>`` Snapshot description (Default=``None``)
|
||
|
||
- ``--metadata [<key=value> [<key=value> ...]]`` Metadata ``key=value`` pairs
|
||
(Default=``None``)
|
||
|
||
Example:
|
||
|
||
.. code-block:: console
|
||
|
||
$ cinder snapshot-manage --name SnapshotManaged \
|
||
--description "Managed Queens Feb18" \
|
||
powermax-vol-1 PowerMaxSnapshot
|
||
|
||
Where:
|
||
|
||
- The name in OpenStack after managing the SnapVX snapshot will be
|
||
``SnapshotManaged``.
|
||
|
||
- The snapshot will have the description ``Managed Queens Feb18``.
|
||
|
||
- The Cinder volume name is ``powermax-vol-1``.
|
||
|
||
- The name of the SnapVX snapshot on the PowerMax backend is
|
||
``PowerMaxSnapshot``.
|
||
|
||
Outcome:
|
||
|
||
After the process of managing the Snapshot has completed, the SnapVX snapshot
|
||
on the PowerMax backend will be prefixed by the letters ``OS-``, leaving the
|
||
snapshot in this example named ``OS-PowerMaxSnapshot``. The associated snapshot
|
||
managed by Cinder will be present for use under the name ``SnapshotManaged``.
|
||
|
||
|
||
Unmanage cinder snapshot
|
||
~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
Unmanaging a snapshot in Cinder is the process whereby the snapshot is removed
|
||
from and no longer managed by Cinder, but it still exists on the storage
|
||
backend. Unmanaging a SnapVX snapshot in OpenStack Cinder follows this
|
||
behaviour, whereby after unmanaging a PowerMax SnapVX snapshot from Cinder, the
|
||
snapshot is removed from OpenStack but is still present for use on the PowerMax
|
||
backend.
|
||
|
||
Requirements/Restrictions:
|
||
|
||
- The SnapVX source volume must not be in a failed over state.
|
||
|
||
Command Structure:
|
||
|
||
Identify the SnapVX snapshot you want to unmanage from OpenStack Cinder, note
|
||
the snapshot name or ID as specified by Cinder. Using the Cinder CLI use the
|
||
following command structure to unmanage the SnapVX snapshot from Cinder:
|
||
|
||
.. code-block:: console
|
||
|
||
$ cinder snapshot-unmanage <snapshot>
|
||
|
||
Positional arguments:
|
||
|
||
- ``<snapshot>`` Cinder snapshot name or ID.
|
||
|
||
Example:
|
||
|
||
.. code-block:: console
|
||
|
||
$ cinder snapshot-unmanage SnapshotManaged
|
||
|
||
Where:
|
||
|
||
- The SnapVX snapshot name in OpenStack Cinder is SnapshotManaged.
|
||
|
||
After the process of unmanaging the SnapVX snapshot in Cinder, the snapshot on
|
||
the PowerMax backend will have the ``OS-`` prefix removed to indicate it is no
|
||
longer OpenStack managed. In the example above, the snapshot after unmanaging
|
||
from OpenStack will be named ``PowerMaxSnapshot`` on the storage backend.
|
||
|
||
List manageable volumes and snapshots
|
||
-------------------------------------
|
||
|
||
Manageable volumes
|
||
~~~~~~~~~~~~~~~~~~
|
||
|
||
Volumes that can be managed by and imported into Openstack.
|
||
|
||
List manageable volume is filtered by:
|
||
|
||
- Volume size should be 1026MB or greater (1GB PowerMax Cinder Vol = 1026 MB)
|
||
- Volume size should be a whole integer GB capacity
|
||
- Volume should not be a part of masking view.
|
||
- Volume status should be ``Ready``
|
||
- Volume service state should be ``Normal``
|
||
- Volume emulation type should be ``FBA``
|
||
- Volume configuration should be ``TDEV``
|
||
- Volume should not be a system resource.
|
||
- Volume should not be ``private``
|
||
- Volume should not be ``encapsulated``
|
||
- Volume should not be ``reserved``
|
||
- Volume should not be a part of an RDF session
|
||
- Volume should not be a SnapVX Target
|
||
- Volume identifier should not begin with ``OS-``.
|
||
- Volume should not be in more than one storage group.
|
||
|
||
Manageable snaphots
|
||
~~~~~~~~~~~~~~~~~~~
|
||
|
||
Snapshots that can be managed by and imported into Openstack
|
||
|
||
List manageable snapshots is filtered by:
|
||
|
||
- The source volume should be marked as SnapVX source.
|
||
- The source volume should be 1026MB or greater
|
||
- The source volume should be a whole integer GB capacity.
|
||
- The source volume emulation type should be ``FBA``.
|
||
- The source volume configuration should be ``TDEV``.
|
||
- The source volume should not be ``private``.
|
||
- The source volume should be not be a system resource.
|
||
- The snapshot identifier should not start with ``OS-`` or ``temp-``.
|
||
- The snapshot should not be expired.
|
||
- The snapshot generation number should npt be greater than 0.
|
||
|
||
.. note::
|
||
|
||
There is some delay in the syncing of the Unisphere for PowerMax database
|
||
when the state/properties of a volume is modified using ``symcli``. To
|
||
prevent this it is preferable to modify state/properties of volumes within
|
||
Unisphere.
|
||
|
||
|
||
Cinder backup support
|
||
---------------------
|
||
|
||
PowerMax Cinder driver support Cinder backup functionality. For further
|
||
information on setup, configuration and usage please see the official
|
||
OpenStack `volume backup`_ documentation and related `volume backup CLI`_
|
||
guide.
|
||
|
||
.. note::
|
||
|
||
``rpc_response_timeout`` may need to be increased significantly in volume
|
||
backup operations especially in replication scenarios where the creation
|
||
operation will be longer. For more information on ``rpc_response_timeout``
|
||
please refer to `Live migration configuration`_
|
||
|
||
|
||
Port group & port load balancing
|
||
--------------------------------
|
||
|
||
By default port groups are selected at random from ``cinder.conf`` when
|
||
connections are initialised between volumes on the backend array and
|
||
compute instances in Nova. If a port group is set in the volume type extra
|
||
specifications this will take precedence over any port groups configured in
|
||
``cinder.conf``. Port selection within the chosen port group is also selected
|
||
at random by default.
|
||
|
||
With port group and port load balancing in the PowerMax for Cinder driver users
|
||
can now select the port group and port load by determining which has the lowest
|
||
load. The load metric is defined by the user in both instances so the selection
|
||
process can better match the needs of the user and their environment. Available
|
||
metrics are detailed in the ``performance metrics`` section.
|
||
|
||
Port Groups are reported on at five minute time deltas (diagnostic), and FE
|
||
Ports are reported on at one minute time deltas (real-time) if real-time
|
||
metrics are enabled, else default five minute time delta (diagnostic). The
|
||
window at which performance metrics are analysed is a user-configured option in
|
||
``cinder.conf``, this is detailed in the ``configuration`` section.
|
||
|
||
Calculating load
|
||
~~~~~~~~~~~~~~~~
|
||
|
||
The process by which Port Group or Port load is calculated is the same for
|
||
both. The user specifies the look back window which determines how many
|
||
performance intervals to measure, 60 minutes will give 12 intervals of 5
|
||
minutes each for example. If no lookback window is specified or is set to
|
||
0 only the most recent performance metric will be analysed. This will give a
|
||
slight performance improvement but with the improvements made to the
|
||
performance REST endpoints for load this improvement is negligible.
|
||
For real-time stats a minimum of 1 minute is required.
|
||
|
||
Once a call is made to the performance REST endpoints, the performance data for
|
||
that PG or port is extracted. Then the metric values are summed and divided by
|
||
the count of intervals to get the average for the look back window.
|
||
|
||
The performance metric average value for each asset is added to a Python heap.
|
||
Once all assets have been measured the lowest value will always be at position
|
||
0 in the heap so there is no extra time penalty requirement for search.
|
||
|
||
|
||
Pre-requisites
|
||
~~~~~~~~~~~~~~
|
||
|
||
Before load balancing can be enabled in the PowerMax for Cinder driver
|
||
performance metrics collection must be enabled in Unisphere. Real-time
|
||
performance metrics collection is enabled separately from diagnostic metrics
|
||
collection. Performance metric collection is only available for local arrays
|
||
in Unisphere.
|
||
|
||
After performance metrics registration there is a time delay before Unisphere
|
||
records performance metrics, adequate time must be given before enabling load
|
||
balancing in Cinder else default random selection method will be used. It is
|
||
recommended to wait 4 hours after performance registration before enabling
|
||
load balancing in Cinder.
|
||
|
||
|
||
Configuration
|
||
~~~~~~~~~~~~~
|
||
|
||
A number of configuration options are available for users so load balancing
|
||
can be set to better suit the needs of the environment. These configuration
|
||
options are detailed in the table below.
|
||
|
||
.. table:: Load balance cinder.conf configuration options
|
||
|
||
+-----------------------------+----------------+-----------------+----------------------------------------+
|
||
| ``cinder.conf parameter`` | options | Default | Description |
|
||
+=============================+================+=================+========================================+
|
||
| ``load_balance`` | ``True/False`` | ``False`` | | Enable/disable load balancing for |
|
||
| | | | | a PowerMax backend. |
|
||
+-----------------------------+----------------+-----------------+----------------------------------------+
|
||
| ``load_balance_real_time`` | ``True/False`` | ``False`` | | Enable/disable real-time performance |
|
||
| | | | | metrics for Port level metrics |
|
||
| | | | | (not available for Port Group). |
|
||
+-----------------------------+----------------+-----------------+----------------------------------------+
|
||
| ``load_data_format`` | ``Avg/Max`` | ``Avg`` | | Performance data format, not |
|
||
| | | | | applicable for real-time. |
|
||
+-----------------------------+----------------+-----------------+----------------------------------------+
|
||
| ``load_lookback`` | ``int`` | ``60`` | | How far in minutes to look back for |
|
||
| | | | | diagnostic performance metrics in |
|
||
| | | | | load calculation, minimum of 0 |
|
||
| | | | | maximum of 1440 (24 hours). |
|
||
+-----------------------------+----------------+-----------------+----------------------------------------+
|
||
| ``load_real_time_lookback`` | ``int`` | ``1`` | | How far in minutes to look back for |
|
||
| | | | | real-time performance metrics in |
|
||
| | | | | load calculation, minimum of 1 |
|
||
| | | | | maximum of 60 (24 hours). |
|
||
+-----------------------------+----------------+-----------------+----------------------------------------+
|
||
| ``port_group_load_metric`` | See below | ``PercentBusy`` | | Metric used for port group load |
|
||
| | | | | calculation. |
|
||
+-----------------------------+----------------+-----------------+----------------------------------------+
|
||
| ``port_load_metric`` | See below | ``PercentBusy`` | | Metric used for port group load |
|
||
| | | | | calculation. |
|
||
+-----------------------------+----------------+-----------------+----------------------------------------+
|
||
|
||
Port-Group Metrics
|
||
~~~~~~~~~~~~~~~~~~
|
||
|
||
.. table:: Port-group performance metrics
|
||
|
||
+-------------------+--------------------+-----------------------------------------------------------+
|
||
| Metric | cinder.conf option | Description |
|
||
+===================+====================+===========================================================+
|
||
| % Busy | ``PercentBusy`` | The percent of time the port group is busy. |
|
||
+-------------------+--------------------+-----------------------------------------------------------+
|
||
| Avg IO Size (KB) | ``AvgIOSize`` | | Calculated value: (HA Kbytes transferred per sec / |
|
||
| | | | total IOs per sec) |
|
||
+-------------------+--------------------+-----------------------------------------------------------+
|
||
| Host IOs/sec | ``IOs`` | | The number of host IO operations performed each second, |
|
||
| | | | including writes and random and sequential reads. |
|
||
+-------------------+--------------------+-----------------------------------------------------------+
|
||
| Host MBs/sec | ``MBs`` | The number of host MBs read each second. |
|
||
+-------------------+--------------------+-----------------------------------------------------------+
|
||
| MBs Read/sec | ``MBRead`` | The number of reads per second in MBs. |
|
||
+-------------------+--------------------+-----------------------------------------------------------+
|
||
| MBs Written/sec | ``MBWritten`` | The number of writes per second in MBs. |
|
||
+-------------------+--------------------+-----------------------------------------------------------+
|
||
| Reads/sec | ``Reads`` | The average number of host reads performed per second. |
|
||
+-------------------+--------------------+-----------------------------------------------------------+
|
||
| Writes/sec | ``Writes`` | The average number of host writes performed per second. |
|
||
+-------------------+--------------------+-----------------------------------------------------------+
|
||
|
||
Port Metrics
|
||
~~~~~~~~~~~~
|
||
|
||
.. table:: Port performance metrics
|
||
|
||
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||
| Metric | cinder.conf option | Real-Time Supported | Description |
|
||
+=====================+=======================+=====================+============================================================+
|
||
| % Busy | ``PercentBusy`` | Yes | The percent of time the port is busy. |
|
||
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||
| Avg IO Size (KB) | ``AvgIOSize`` | Yes | | Calculated value: (HA Kbytes transferred per sec / |
|
||
| | | | | total IOs per sec) |
|
||
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||
| Host IOs/sec | ``IOs`` | Yes | | The number of host IO operations performed each second, |
|
||
| | | | | including writes and random and sequential reads. |
|
||
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||
| Host MBs/sec | ``MBs`` | Yes | The number of host MBs read each second. |
|
||
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||
| MBs Read/sec | ``MBRead`` | Yes | The number of reads per second in MBs. |
|
||
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||
| MBs Written/sec | ``MBWritten`` | Yes | The number of writes per second in MBs. |
|
||
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||
| Reads/sec | ``Reads`` | Yes | The number of read operations performed by the port per |
|
||
| | | | second. |
|
||
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||
| Writes/sec | ``Writes`` | Yes | The number of write operations performed each second by |
|
||
| | | | the port. |
|
||
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||
| Speed Gb/sec | ``SpeedGBs`` | No | Speed. |
|
||
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||
| Response Time (ms) | ``ResponseTime`` | No | The average response time for the reads and writes. |
|
||
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||
| Read RT (ms) | ``ReadResponseTime`` | No | The average time it takes to serve one read IO. |
|
||
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||
| Write RT (ms) | ``WriteResponseTime`` | No | The average time it takes to serve one write IO. |
|
||
+---------------------+-----------------------+---------------------+------------------------------------------------------------+
|
||
|
||
|
||
Upgrading from SMI-S based driver to REST API based driver
|
||
==========================================================
|
||
|
||
Seamless upgrades from an SMI-S based driver to REST API based driver,
|
||
following the setup instructions above, are supported with a few exceptions:
|
||
|
||
#. Seamless upgrade from SMI-S(Ocata and earlier) to REST(Pike and later)
|
||
is now available on all functionality including Live Migration.
|
||
|
||
#. Consistency groups are deprecated in Pike. Generic Volume Groups are
|
||
supported from Pike onwards.
|
||
|
||
|
||
.. Document Hyperlinks
|
||
.. _Dell EMC Support: https://www.dell.com/support
|
||
.. _Openstack CLI: https://docs.openstack.org/cinder/latest/cli/cli-manage-volumes.html#volume-types
|
||
.. _over-subscription documentation: https://docs.openstack.org/cinder/latest/admin/blockstorage-over-subscription.html
|
||
.. _configuring migrations: https://docs.openstack.org/nova/latest/admin/configuring-migrations.html
|
||
.. _live migration usage: https://docs.openstack.org/nova/latest/admin/live-migration-usage.html
|
||
.. _Ubuntu NFS Documentation: https://help.ubuntu.com/lts/serverguide/network-file-system.html
|
||
.. _multi-attach documentation: https://docs.openstack.org/cinder/latest/admin/blockstorage-volume-multiattach.html
|
||
.. _Data at Rest Encryption: https://www.dellemc.com/resources/en-us/asset/white-papers/products/storage/h13936-dell-emc-powermax-vmax-all-flash-data-rest-encryption.pdf
|
||
.. _official Barbican documentation: https://docs.openstack.org/cinder/latest/configuration/block-storage/volume-encryption.html
|
||
.. _SRDF Metro Overview & Best Practices: https://www.emc.com/collateral/technical-documentation/h14556-vmax3-srdf-metro-overview-and-best-practices-tech-note.pdf
|
||
.. _block-storage groups: https://docs.openstack.org/cinder/latest/admin/blockstorage-groups.html
|
||
.. _volume backup: https://docs.openstack.org/cinder/latest/configuration/block-storage/backup-drivers.html
|
||
.. _volume backup CLI: https://docs.openstack.org/python-openstackclient/latest/cli/command-objects/volume-backup.html
|
||
.. _PyU4V: https://pyu4v.readthedocs.io/en/latest/
|
||
.. _Create volume types: `6. Create volume types`_
|