Replacing failed hardware
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
It is essential to plan and know how to replace failed hardware in your cluster
|
|
without compromising your cloud environment.
|
|
|
|
Consider the following to help establish a hardware replacement plan:
|
|
|
|
- What type of node am I replacing hardware on?
|
|
- Can the hardware replacement be done without the host going down? For
|
|
example, a single disk in a RAID-10.
|
|
- If the host DOES have to be brought down for the hardware replacement, how
|
|
should the resources on that host be handled?
|
|
|
|
If you have a Compute (nova) host that has a disk failure on a
|
|
RAID-10, you can swap the failed disk without powering the host down. On the
|
|
other hand, if the RAM has failed, you would have to power the host down.
|
|
Having a plan in place for how you will manage these types of events is a vital
|
|
part of maintaining your OpenStack environment.
|
|
|
|
For a Compute host, shut down instances on the host before
|
|
it goes down. For a Block Storage (cinder) host using non-redundant storage,
|
|
shut down any instances with volumes attached that require that mount point.
|
|
Unmount the drive within your operating system and re-mount the drive once the
|
|
Block Storage host is back online.
|