The Storage Architecture Overview is revised to include the new diagrams and to use them to explain design considerations when implementing a production OpenStack environment. This patch includes the move of the storage diagrams to the new location. Change-Id: Ie63466b16e2d61b3d82f73462dbf709ae04e4994
178 lines
8.8 KiB
ReStructuredText
178 lines
8.8 KiB
ReStructuredText
====================
|
|
Storage architecture
|
|
====================
|
|
|
|
Introduction
|
|
~~~~~~~~~~~~
|
|
|
|
OpenStack has multiple storage realms to consider:
|
|
|
|
* Block Storage (cinder)
|
|
* Object Storage (swift)
|
|
* Image storage (glance)
|
|
* Ephemeral storage (nova)
|
|
|
|
Block Storage (cinder)
|
|
~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The Block Storage (cinder) service manages volumes on storage devices in an
|
|
environment. For a production deployment, this is a device that presents
|
|
storage via a storage protocol (for example: NFS, iSCSI, Ceph RBD) to a
|
|
storage network (``br-storage``) and a storage management API to the
|
|
management (``br-mgmt``) network. Instances are connected to the volumes via
|
|
the storage network by the hypervisor on the Compute host. The following
|
|
diagram illustrates how Block Storage is connected to instances.
|
|
|
|
.. figure:: figures/production-storage-cinder.png
|
|
:width: 600px
|
|
|
|
The following steps relate to the illustration above.
|
|
|
|
+----+---------------------------------------------------------------------+
|
|
| 1. | The creation of a volume is executed by the assigned |
|
|
| | ``cinder-volume`` service using the appropriate `cinder driver`_. |
|
|
| | This is done using an API which is presented to the management |
|
|
| | network. |
|
|
+----+---------------------------------------------------------------------+
|
|
| 2. | After the volume is created, the ``nova-compute`` service connects |
|
|
| | the Compute host hypervisor to the volume via the storage network. |
|
|
+----+---------------------------------------------------------------------+
|
|
| 3. | After the hypervisor is connected to the volume, it presents the |
|
|
| | volume as a local hardware device to the instance. |
|
|
+----+---------------------------------------------------------------------+
|
|
|
|
.. important::
|
|
|
|
The `LVMVolumeDriver`_ is designed as a reference driver implementation
|
|
which we do not recommend for production usage. The LVM storage back-end
|
|
is a single server solution which provides no high availability options.
|
|
If the server becomes unavailable, then all volumes managed by the
|
|
``cinder-volume`` service running on that server become unavailable.
|
|
Upgrading the operating system packages (for example: kernel, iscsi) on
|
|
the server will cause storage connectivity outages due to the iscsi
|
|
service (or the host) restarting.
|
|
|
|
Due to a `limitation with container iSCSI connectivity`_, you must deploy the
|
|
``cinder-volume`` service directly on a physical host (not into a container)
|
|
when using storage back-ends which connect via iSCSI. This includes the
|
|
`LVMVolumeDriver`_ and many of the drivers for commercial storage devices.
|
|
|
|
.. note::
|
|
|
|
The ``cinder-volume`` service does not run in a highly available
|
|
configuration. When the ``cinder-volume`` service is configured to manage
|
|
volumes on the same back-end from multiple hosts/containers, one service
|
|
is scheduled to manage the life-cycle of the volume until an alternative
|
|
service is assigned to do so. This assignment may be done through by
|
|
using the `cinder-manage CLI tool`_.
|
|
This may change in the future if the
|
|
`cinder volume active-active support spec`_ is implemented.
|
|
|
|
.. _cinder driver: http://docs.openstack.org/developer/cinder/drivers.html
|
|
.. _LVMVolumeDriver: http://docs.openstack.org/developer/cinder/drivers.html#lvmvolumedriver
|
|
.. _limitation with container iSCSI connectivity: https://bugs.launchpad.net/ubuntu/+source/lxc/+bug/1226855
|
|
.. _cinder-manage CLI tool: http://docs.openstack.org/developer/cinder/man/cinder-manage.html#cinder-volume
|
|
.. _cinder volume active-active support spec: https://specs.openstack.org/openstack/cinder-specs/specs/mitaka/cinder-volume-active-active-support.html
|
|
|
|
Object Storage (swift)
|
|
~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The Object Storage (swift) service implements a highly available, distributed,
|
|
eventually consistent object/blob store which is accessible via HTTP/HTTPS.
|
|
|
|
The following diagram illustrates how data is accessed and replicated.
|
|
|
|
.. figure:: figures/production-storage-swift.png
|
|
:width: 600px
|
|
|
|
The ``swift-proxy`` service is accessed by clients via the load balancer
|
|
on the management (``br-mgmt``) network. The ``swift-proxy`` service
|
|
communicates with the Account, Container and Object services on the
|
|
``swift_hosts`` via the storage (``br-storage``) network. Replication
|
|
between the ``swift_hosts`` is done via the replication (``br-repl``)
|
|
network.
|
|
|
|
Image storage (glance)
|
|
~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The Image service (glance) may be configured to store images on a variety of
|
|
storage back-ends supported by the `glance_store drivers`_.
|
|
|
|
.. important::
|
|
|
|
When using the File System store, glance has no mechanism of its own to
|
|
replicate the image between glance hosts. We recommend using a shared
|
|
storage back-end (via a file system mount) to ensure that all
|
|
``glance-api`` services have access to all images. This prevents the
|
|
unfortunate situation of losing access to images when a control plane host
|
|
is lost.
|
|
|
|
The following diagram illustrates the interactions between the glance service,
|
|
the storage device, and the ``nova-compute`` service when an instance is
|
|
created.
|
|
|
|
.. figure:: figures/production-storage-glance.png
|
|
:width: 600px
|
|
|
|
The following steps relate to the illustration above.
|
|
|
|
+----+---------------------------------------------------------------------+
|
|
| 1. | When a client requests an image, the ``glance-api`` service |
|
|
| | accesses the appropriate store on the storage device over the |
|
|
| | storage (``br-storage``) network and pulls it into its cache. When |
|
|
| | the same image is requested again, it is given to the client |
|
|
| | directly from the cache instead of re-requesting it from the |
|
|
| | storage device. |
|
|
+----+---------------------------------------------------------------------+
|
|
| 2. | When an instance is scheduled for creation on a Compute host, the |
|
|
| | ``nova-compute`` service requests the image from the ``glance-api`` |
|
|
| | service over the management (``br-mgmt``) network. |
|
|
+----+---------------------------------------------------------------------+
|
|
| 3. | After the image is retrieved, the ``nova-compute`` service stores |
|
|
| | the image in its own image cache. When another instance is created |
|
|
| | with the same image, the image is retrieved from the local base |
|
|
| | image cache instead of re-requesting it from the ``glance-api`` |
|
|
| | service. |
|
|
+----+---------------------------------------------------------------------+
|
|
|
|
.. _glance_store drivers: http://docs.openstack.org/developer/glance_store/drivers/
|
|
|
|
Ephemeral storage (nova)
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
When the flavors in the Compute service are configured to provide instances
|
|
with root or ephemeral disks, the ``nova-compute`` service manages these
|
|
allocations using its ephemeral disk storage location.
|
|
|
|
In many environments, the ephemeral disks are stored on the Compute host's
|
|
local disks, but for production environments we recommended that the Compute
|
|
hosts are configured to use a shared storage subsystem instead.
|
|
|
|
Making use of a shared storage subsystem allows the use of quick live instance
|
|
migration between Compute hosts. This is useful when the administrator needs
|
|
to perform maintenance on the Compute host and wants to evacuate it.
|
|
Using a shared storage subsystem also allows the recovery of instances when a
|
|
Compute host goes offline. The administrator is able to evacuate the instance
|
|
to another Compute host and boot it up again.
|
|
|
|
The following diagram illustrates the interactions between the
|
|
storage device, the Compute host, the hypervisor and the instance.
|
|
|
|
.. figure:: figures/production-storage-nova.png
|
|
:width: 600px
|
|
|
|
The following steps relate to the illustration above.
|
|
|
|
+----+---------------------------------------------------------------------+
|
|
| 1. | The Compute host is configured with access to the storage device. |
|
|
| | The Compute host accesses the storage space via the storage network |
|
|
| | (``br-storage``) using a storage protocol (for example: NFS, iSCSI, |
|
|
| | Ceph RBD). |
|
|
+----+---------------------------------------------------------------------+
|
|
| 2. | The ``nova-compute`` service configures the hypervisor to present |
|
|
| | the allocated instance disk as a device to the instance. |
|
|
+----+---------------------------------------------------------------------+
|
|